• Title/Summary/Keyword: 대당회수

Search Result 6, Processing Time 0.017 seconds

Estimation of Fugitive Emission Factors of HFC-134a from Scrap Cold Drinking Vending Machine at Use- and Disposal-Phase (음료용 폐자동판매기에서의 HFC-134a 사용 및 폐기단계 탈루배출계수 결정에 대한 연구)

  • Lee, Youngphyo;Kim, Eui-Kun;Kim, Seungdo;Byun, Seokho;Kim, Hyerim;Park, Junho;Lee, Dongwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.350-355
    • /
    • 2013
  • Little information is available for emission pathway even if HFC-134a that is known as one of the major greenhouse gases has been broadly used in Korea. This paper attempts to clarify the emission characteristics of HFC-134a used for refrigerant of cold drinking vending machines (CDVMs) at the use- and disposal-phase. We measured the residual amounts in the scrap CDVMs of 47 by applying commercial recover for refrigerant. The first-order kinetic model was introduced and the emission rate would be proportional to the remaining quantity of refrigerant. The emission factor at the use-phase was determined indirectly to be $6.9{\pm}0.7$ %/yr within a confidence interval of 95%, using information on residual amount and elapsed operation time at the disposal point. Correspondingly, the annual emission rate of HFC-134a per CDVM was determined to be 11.6 g. The average residual rate of HFC-134a in scrap CDVMs was assessed to be $62.5{\pm}2.2%$, leading to a potential emission amount of 144.8 g per scrap CDVM. The chemical compositions of refrigerants from scrap passenger vehicles are quite similar to those of new refrigerants, suggesting that the refrigerants from scrap passenger vehicles could be reused. During the recovering process of refrigerant, the recovered refrigerant was contaminated by compressor lubricant that accounted for about 30% in weight. It is necessary to separate the refrigerant from the recovered material contaminated by lubricant for recycling and reuse the refrigerant.

Development of Optimal Bus Scheduling Algorithm with Multi-constraints (다중제약을 고려한 최적 버스운행계획 알고리즘 개발)

  • Lee, Ho-Sang;Park, Jong-Heon;Jo, Seong-Hun;Yun, Byeong-Jo
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.7 s.93
    • /
    • pp.129-138
    • /
    • 2006
  • After Seoul has introduced semi-public bus management system(public management-private operation), the Seoul Metro Government needs a scientific management tool for optimal scheduling for bus routes, to reduce unnecessary operations and provide demand responsive service. As a product of this effort, this paper proposes a heuristic model that could minimize total passenger waiting time under the constraints, such as number of vehicles, working conditions, max load point, minimax headway. etc. For verifying the validity of the proposed model, it is applied to an existing bus route. It results that headways in rush hours become decreased and the passenger waiting time could be decreased. In conclusion. it is thought that the Proposed model contributes to efficiency of bus operation.

A Survey on the Break-down and Repair of the Power Tillers in Korea (동력경운기(動力耕耘機) 이용실태(利用實態) 조사분석(調査分析)(II) -고장(故障) 및 수리(修理)에 관(關)하여-)

  • Hong, Jong Ho;Lee, Chai Shik
    • Journal of Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.28-38
    • /
    • 1981
  • A survey has been conducted to investigate the presents of breaks down and repair of power tiller for efficient use. Eight provinces were covered for this study. The results are summarized as follows. A. Frequency of breaks down. 1) Power tiller was breaken down 9.05 times a year and it represents a break down every 39.1 hours of use. High frequency of breaks down was found from the fuel and ignition system. For only these system, the number of breaks down were 2.02 and it represents 23.3% among total breaks down. It was followed by attachments, cylinder system, and traction device. 2) For the power tiller which was more than six years old, breaks down accured 37.7 hours of use and every 38.6 hours for the power tiller which was purchased in less than 2 years. 3) For the kerosene engine power tiller, breaks down occured every 36.8 hours of use, which is a higher value compared with diesel engine power tiller which break down every 42.8 hours of use. The 8HP kerosene engine power tiller showed higher frequency of break down compared with any other horse power tiller. 4) In October, the lowest frequency of break down was found with the value of once for every 51.5 hours of use, and it was followed by the frequency of break down in June. The more hours of use, the less breaks down was found. E. Repair place 1) 45.3% among total breaks down of power tiller was repaired by the owner, and 54.7% was repaired at repair shop. More power tiller were repaired at repair shop than by owner of power tiller. 2) The older the power tiller is, the higher percentage of repairing at the repair shop was found compared with the repairing by the owner. 3) Higher percentage of repairing by the owner was found for the diesel engine power tiller compared with the kerosene engine power tiller. It was 10 HP power tiller for the kerosene power tiller and 8 HP for the diesel engine power tiller. 4) 66.7% among total breaks down of steering device was repaired by the owner. It was the highest value compared with the percentage of repairing of any other parts of power tiller. The lowest percentage of repairing by owner was found for the attachments to the power tiller with the value of 26.5%. C. Cause of break down 1) Among the total breaks down of power tiller, 57.2% is caused by the old parts of power tiller with the value of 5.18 times break down a year and 34.7% was caused by the poor maintenance and over loading. 2) For the power tiller which was purchased in less than two years, more breaks down were caused by poor maintenance in comparison to the old parts of power tiller. 3) For the both 8-10 HP kerosene and diesel engine power tiller, the aspects of breaks down was almost the same. But for the 5 HP power tiller, more breaks down was caused by over loading in comparison to the old parts of power tiller. 4) For the cylinder system and traction device, most of the breaks down was caused by the old parts and for the fuel and ignition system, breaks down was caused mainly by the poor maintenance. D. Repair Cost 1) For each power tiller, repair cost was 34,509 won a year and it was 97 won for one hoar operation. 2) Repair cost of kerosene engine power tiller was 40,697 won a year, and it use 28,320 won for a diesel engine power tiller. 3) Average repair cost for one hour operation of kerosene engine power tiller was 103 won, and 86 won for a diesel engine power tiller. No differences were found between the horse power of engines. 4) Annual repair cost of cylinder system was 13,036 won which is the highest one compared with the repair cost of any other parts 362 won a year was required to repair the steering device, and it was the least among repair cost of parts. 5) Average cost for repairing the power tiller one time was 3,183 won. It was 10,598 won for a cylinder system and 1,006 won for a steering device of power tiller. E. Time requirement for repairing by owner. 1) Average time requirements for repairing the break down of a power tiller by owner himself was 8.36 hours, power tiller could not be used for operation for 93.58 hours a year due to the break down. 2) 21.3 hours were required for repairing by owner himself the break down of a power tiller which was more than 6 years old. This value is the highest one compared with the repairing time of power tiller which were purchased in different years. Due to the break down of the power tiller, it could not be used for operation annually 127.13 hours. 3) 10.66 hours were required for repairing by the owner himself a break down of a diesel engine power tiller and 6.48 hours for kerosene engine power tiller could not be used annually 99.14 hours for operation due to the break down and it was 88.67 hour for the diesel engine power tiller. 4) For both diesel and kerosene engine power tiller 8 HP power tiller required the least time for repairing by owner himself a break down compared with any other horse power tiller. It was 2.78 hours for kerosene engine power tiller and 8.25 hours fur diesel engine power tiller. 5) For the cylinder system of power tiller 32.02 hours were required for repairing a break down by the owner himself. Power tiller could not be used 39.30 hours a year due to the break down of the cylinder system.

  • PDF

An Investigation of the Effect of Government Subsidy Scheme to Bus Industry on the Efficiency of Inner-City Bus Route System (버스 재정지원체계 변화가 버스노선 효율성에 미치는 영향 분석)

  • Jung, Byung Doo;Kim, Kyoung Sik;Kim, Ki Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2455-2464
    • /
    • 2013
  • This study is focused on the effect of reformation of public transportation system on the efficiency of bus route system as a result of change of government subsidy scheme. Two types of government subsidy scheme has been considered and before and after analysis by Data Envelopment Analysis technique has been carried out for bus routes in Ulsan Metropolitan City. The analysis output has shown that there is no clear evidence to clarify the relationship between the change of government subsidy scheme and the efficiency of bus route system. There are two types of backgrounds may be suggested for this situation such as more longer period necessary to identify the policy effect and limitation to increase the number of passenger in a provincial city. Tobit regression analysis has also been conducted to discover the most effective variables for maximum efficiency and three variables including route length, frequency per vehicle per day, and headway are found to be influential. It is also seen that strategy to minimising input factors and service upgrade plan such as shortened route length and headway, increasing frequency per vehicle are necessary to develop the efficiency of bus routes operated in Ulsan city.

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.