Single Particle Characterization of Aerosols at Cheju Island, Korea, Using Low-Z Electron Probe X-ray Microanalysis (Low-Z Electron Probe X-ray Microanalysis를 이용한 제주도 고산에서의 입자상물질의 단일 입자 분석)

  • 안용훈;노철언;김혜경
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.354-355
    • /
    • 2002
  • Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia) Project의 1차 집중 관측기간 중에 2001년 4월 4일부터 일주일 동안 제주도 고산에서 채취한 시료에 대하여 low-Z electron probe X-ray microanalysis (low-Z EPMA)를 이용한 입자상물질의 단일 입자 분석을 수행하였다. 시료채취 장소인 제주도는 대기 중 입자상물질에 대한 대륙과 해양의 영향을 연구하는데 이상적인 장소이다 왜냐하면 제주로는 한반도, 중국대륙, 일본, 그리고 황해로 둘러 쌓여있어서 대륙간의 영향을 많이 받지만 그 자체가 청정지역이라 측정결과의 해석이 용이하기 때문이다. (중략)

  • PDF

Surface Characteristics by Atmospheric Pressure Plasma Treatment (대기압 플라즈마 처리에 의한 표면 특성 변화)

  • Lee, Chang-Ho;Lee, Hyun-Chul;Song, Hyun-Jig;Chun, Byung-Joon;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.265-268
    • /
    • 2008
  • 본 연구에서는 대기압 플라즈마의 처리 조건에 따른 Tri-acteyl-cellulose (TAC) 필름의 접착력 향상을 위한 접촉각 및 표면에너지의 변화를 관찰하였다. 대기압 플라즈마의 처리 변수로는 처리 속도, 방전 전력, 시료와 플라즈마 헤드 사이의 간격 및 $N_2$ 가스 유속이며, 각각의 처리 변수가 TAC 필름의 표면 특성 변화에 미치는 영향을 조사하였다. 실험결과 방전전력 및 $N_2$ 유량이 증가할수록 접촉각은 낮아지고 표면에너지는 증가하였다. 그리고 시료와 플라즈마 헤드 사이의 방전 간격은 2[mm]에서 접촉각이 낮고 표면에너지가 높게 나타나 TAC 필름의 접착력 향상을 위한 친수성 물질로 표면 개질됨을 확인할 수 있었다.

  • PDF

Surface Characteristics of PMMA by Atmospheric Pressure Plasma Treatment (대기압 플라즈마 처리에 의한 PMMA의 표면개질 특성)

  • Lee, Chang-Ho;Chun, Byung-Joon;Lee, Jae-Bok;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.313-316
    • /
    • 2009
  • 본 연구에서는 대기압 플라즈마의 처리 조건에 따른 폴리프로필렌(PMMA)의 접착력 향상을 위한 접촉각 및 표면에너지의 변화를 관찰하였다. 대기압 플라즈마의 처리 변수로는 처리 속도, 방전 전력, 시료와 플라즈마 헤드 사이의 방전 갭이며, 측정된 접촉각을 이용하여 표면에너지 변화를 계산한 후 접촉각 및 표면에너지의 변화를 분석하였다. 그 결과는 방전전력이 증가할수록 접촉각은 낮아지고 표면에너지는 증가하였으며, 시료와 플라즈마 헤드 사이의 방전 간격은 3[mm]에서 접촉각이 낮고 표면에너지가 높게 나타나 PMMA의 접착력 향상을 위한 친수성 물질로 표면 개질됨을 확인할 수 있었다.

  • PDF

Gas/particle Partitioning of PAHs Segregated with Particle Size in Equilibrium States (대기 중 PAHs의 입경별 가스/입자 분배평형에 관한 연구)

  • Park, Jin-Soo;Lee, Dong-Soo;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1270-1276
    • /
    • 2005
  • When gas/particle partitioning of PAHs in the atmosphere approached an equilibrium state, the slope of linear regression between gas/particle partitioning coefficient($logK_p$) and subcooled liquid vapour pressure($logP_L^O$) was -1. But it was alleged that the slope of equilibrium state might not be -1 in real atmospheric environment due to heterogeneous characteristics of particulate matter. In This study, it would be found if gas/particle partitioning of PAHs segregated with particle size in equilibrium state was based on the hypothesis mentioned above. We have calculated the slopes of $logK_p$ v.s. $logP_L^O$ after collecting 10 set samples which consisted of particulate and vaporous phases. The slope was close to -1 in equilibrium states. But despite of equilibrium state, all slopes segregated with particle size were not close to -1 and those were gentler with larger particle size. The difference of slopes in equilibrium states was almost against the assumption of gas/particle partitioning theory. When the gas/particle partitioning was due to adsorption, the desorption enthalpy was different in each particle size. When it was absorption, the activity coefficient was different. The difference of desorption enthalpy and activity coefficient in each particle size indicate the heterogeneous characteristics of the bulk particle. This may be the reason for slope variation with particle size even though in an equilibrium state.

NMHCs measurement using a cryogenic concentration system and application on gas samples (저온농축장치를 이용한 NMHCs의 측정법과 가스 시료에 적용)

  • Kim, Su Ha;Moon, Dong Min;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.375-381
    • /
    • 2012
  • In this study, we have developed a cryogenic concentration system for the analysis of non-methane hydrocarbons (NMHCs) in air sample. NMHCs with nmol/mol level of concentrations in the atmosphere were quantified by a comparative method with certified reference gas mixture. GC/FID with cryogenic concentration system operated in the range from $-67^{\circ}C$ to $180^{\circ}C$ was adopted. After cryogenic concentration, a fast desorption by heating could achieve a large amount of sample injection into the GC/FID. The linearity of the system was verified with the peak areas of NMHCs of the concentration amount of sample. The reproducibility is less than 10% and the limit of detection (LOD) is 0.1 nmol/mol. For the application of this system, we analyzed NMHCs in gas samples taken from air and soil in Daejeon, Seosan and Goheung.

A Study on Identification of Source Using SEM-EDX by Analysis of shape and chemical composition in individual Particles (SEM-EDX법을 이용한 개별입자의 형상과 화학적 조성 분석을 통한 발생원 추정에 관한 연구)

  • 염해진;전보경;최금찬
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.320-321
    • /
    • 2003
  • 대기중에 존재하는 입자상물질은 광범위한 입경역에 걸쳐서 다종다양한 미량화학성분으로 구성되는 분산체이고, 그 성상은 공간적으로도 시간적으로도 크게 변동한다. 입자상 물질의 화학분석법은 발생원 동정을 위한 자료로 적합하며 일반적으로는 습식의 파괴적인 원소분석으로 하는 경우가 많다. 일반적으로 화학적 분석법은 개별입자의 정보가 무시되며 필터에 포집된 bulk 시료에 의한 분석이 진행되므로 장시간 포집에 의한 단시간의 시간변동과 개개의 입자가 가지는 정보가 무시되고 평균화 되어버린다. (중략)

  • PDF