• Title/Summary/Keyword: 단층토

Search Result 100, Processing Time 0.043 seconds

Case Study about the Ground Characteristics Analysis of Tunnel Face Fault Fractured Zone (터널막장 단층파쇄대의 지반특성 분석에 대한 사례연구)

  • Min Kyoung-Nam;Lim Kwang-Su;Jang Chang-Sik;Lim Dae-Hwan
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.111-118
    • /
    • 2005
  • The area of investigation belongs to Okchon metamorphic zone and the fault fractured zone runs parallel to the tunnel direction. It causes the independent decline of tunnel face and the slackness of the tunnel surrounding base so, after all, the severe displacement has occurred within the tunnel. Accordingly, the TSP(Tunnel Seismic Prediction) survey has been performed to investigate the extent of fault fractured zone and to analize its characteristics. Also, we have analized the behavior causes by performing the tunnel face mapping and drilling investigation, and confirmed the position and scale of geological anomaly area and front fractured zone which influences tunnel excavation and supporting. Collected data analyzed ground layer condition through 3 dimensional modeling. Several variables included in the modeling were analyzed by geostastistics. The analysis of the modeling data shows that the belt of weathering by fault fractured zone is developing on the basis of the right side of tunnel and that is decreasing to the left side. The fault fractured zone was confirmed that it has strike, $N0\~5^{\circ}E$ dip NW, and it is consisted of large-scale fractured zone including several anomalies. The severe displacement in tunnel is probably caused by asymmetrical load that n generated by the crossing of discontinuity and the rock strength imbalance of tunnel's both side by fault fractured zone, and judge that need tunnel reinforcement method of grouting etc.

Reviewing geology and groundwater change in a fault zone caused by tunnel construction (터널공사에 의한 단층대 지역의 지질 및 지하수 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Lee, Chung-Mo;Lim, Woo-Ri;Yun, Sul-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.466-466
    • /
    • 2017
  • 지하공간의 개발과 지하공간의 굴착으로 인한 지표수 및 지하수 시스템의 변화나 굴착면 주위의 지하수 유동 체계의 변화는 터널내로의 지하수 유입, 지표수 고갈을 가져온다. 또한 터널 상부의 지반에서 현지응력의 변화로 인한 지하수 유출은 지표침하, 하천수 및 계곡수 고갈을 발생시킬 수 있다. 그러나, 터널설계 시 비용 및 시간, 현장의 진입조건 등의 제약으로 상세한 지반조사의 실시가 이루어지지 않을 때가 있다. 또한, 터널 공사가 진행되는 중에는 공사기간과 공사비 때문에 별도의 지반조사를 하지 않는다. 그 대신에 터널 막장에서 실시하는 Face Mapping을 토대로 공사를 진행하며, 대규모 위험요소가 발견되지 않는 이상 별도의 비용과 시간을 투입하여 추가 지질 및 지반 조사를 실시하는 경우는 매우 드물다. 연구지역의 지질은 경상분지내 백악기 하양층군의 퇴적암류, 이를 관입/분출한 불국사화강암류 및 제3기 화산암류, 전기 에오세 연일층군에 대비되는 퇴적암류로 구성되어 있다. 이들을 피복하는 제4기 충적 퇴적층은 주로 단층곡과 동측 지괴의 선상지 및 하천을 따라 분포한다. 연구지역에는 폭 100 m 이상의 대규모 단층대가 발달하였으며 제4기 단층운동으로 인한 단층파쇄대가 존재한다. 퇴적암 분포지역에서는 반복층서가 관찰되며 소규모 단층, 단열, 변형띠 등이 연속적으로 발달해 있다. 본 연구에서는 터널공사에 의한 지하수 변화를 확인하기 위하여 현장추적자 시험과 수질분석 및 지하수 모델링을 실시하였다. 현장 수질 분석에 의한 지표수와 지하수 간의 수질의 차이를 보면, 알칼리도를 제외한 대부분의 수질 항목이 서로 유사성을 보인다. 전기전도도(EC), TDS, 알칼리도의 경우 지표수의 수원지에서 터널 내부로 유입이 일어나고 있다. 이는 터널 공사의 영향으로 판단되며, 현장에서 실시한 추적자 시험에서는 추적자의 이동 시간이 매우 빨라 지표 수원지로부터 지표수가 터널내부로 빠른 속도(10시간 이내)로 유입된다고 판단된다. 지하수 모델링 결과, 정상류 상태에서는 지하수가 북동쪽의 높은 고도에서 서남쪽의 낮은 고도로 흐르는 것으로 확인되며, 가뭄시에도 지하수 함양으로 지하수가 고갈되지는 않는 것으로 나타났다. 부정류 상태 모델링 결과, 일일 평균 $32.49m^3$의 지하수가 터널 내부로 유입되는 것으로 산정되었다. 이 양은 터널 내부뿐만 아니라 터널 공사 현장 주위로도 지하수 유출이 일어나고 있음을 지시한다.

  • PDF

한강하저 터널에서의 지반상태에 따른 보강공법 -그라우팅을 중심으로-

  • 박남서
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 1995.03a
    • /
    • pp.27-40
    • /
    • 1995
  • 한강하저의 지질은 수많은 대ㆍ소 단층들로 인해 심하게 교란되어 있어 지질상황의 변화가 매우 심하며, 터널을 굴착함에 있어 지하수의 유입을 차단하는 것이 안전시공을 위한 필수 과제로 직면한다. 본 고에서는 기 시공실적을 바탕으로 암반상태에 따른 차수그라우딩의 패턴을 비교ㆍ검토하였다. 본 구간에서는 암반상태에 따라 5가지 패턴이 적용되었으며, 경암 암반일 경우는 상부반단면만을 주입범위(주입범위 : 3.5m, 28공)로 하고 암반의 전단강도증진을 위해 강관보강을 시행하였다. 연암 암반 내지 파쇄대가 부분적으로 협재된 경우는 상부반단면만을 주입하되 주입범위 및 그라우팅 공수를 늘리는 방식(주입범위 : 5∼7, 42∼56공)으로 보강하였다. 풍화암 암반의 경우는 전단면을 주입범위로 하여 그라우팅 공수를 늘림(주입범위 : 7m, 81공)으로서 차수효과를 증진시켰다. 또한 본 공사구간 중 가장 난제였던 연약지반대(잔류토 내지 풍화토) 85m 구간은 자문회의 등을 거쳐 주입범위, 주입길이 및 주입공수, bulk head 구간을 늘려 시공하고, 굴착하면서 차수효과를 확인하는 방식을 취하였다.

  • PDF

Case Study on Stability Assessment of Pre-existing Fault at CO2 Geologic Storage (CO2 지중저장 시 단층 안정성 평가)

  • Kim, Hyunwoo;Cheon, Dae-Sung;Choi, Byung-Hee;Choi, Hun-Soo;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.23 no.1
    • /
    • pp.13-30
    • /
    • 2013
  • Increase of pore fluid pressure resulting from injection of $CO_2$ may reactivate pre-existing faults, and the induced seismic activities can raise the safety issues such as seal integrity, restoration of storage capacity, and, in the worst case, removal of previously injected $CO_2$. Thus, fault stability and potential for $CO_2$ leakage need to be assessed at the stage of site selection and planning of injection pressure, based on the results of large-scale site investigations and numerical modeling for various scenarios. In this report, studies on the assessment of fault stability during injection of $CO_2$ were reviewed. The seismic activities associated with an artificial injection of fluids or a release of naturally trapped high-pressure fluids were first examined, and then site investigation methods for the magnitude and orientation of in situ stresses, the distribution and change of pore fluid pressure, and the location of faults were generally summarized. Recent research cases on possibility estimation of fault reactivation, prediction of seismic magnitude, and modeling of $CO_2$ leakage through a reactivated fault were presented.

Dioctahedral Chlorite-Smectite Mixed-Layer Minerals in the Sandstones of the Ulleung Basin, Offshore SE Korea (울릉분지 사암 내에 발달된 이팔면체 녹니석 - 스멕타이트 혼합층 광물)

  • Son Byeong-Kook
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2005
  • Mineralogical and chemical examinations were performed on chlorite-smectite mixed layer minerals that occur in the sandstones from a petroleum exploration well in the southern part of the Ulleung Basin. X-ray diffraction and chemical analyses show that the chlorite-smectite mixed layer mineral is tosudite, a 1 : 1 R1 ordered interstratification of chlorite and smectite with an overall dioctahedral character. This mineral is almost the same as the tosudite reported from hydrothermally-altered regions, which is rich in Li. This fact indicates that the tosudite area may be affected by hydrothermal events, because the studied well is located in the tectonically-deformed area, in which lots of trust faults and folds are present. In these respects, the formation of tosudite is probably due to the variable effect of hydrothermal fluids from the deeper part of the area.

Analysis of electrical resistivity characteristics according to the mixing ratio of coarse fillings in artificial rock joint (인공 암반절리의 조립토 충진물 혼합비에 따른 전기비저항 특성 분석)

  • Haeju Do;Tae-Min Oh;Hangbok Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.141-155
    • /
    • 2023
  • Monitoring technology based on electrical resistivity is widely used for non-destructive data collection and health analysis of underground structures and tunnels. Vulnerable sections such as fault zone generates many problems during construction of the tunnel. These problems cause displacement and stress changes of the ground. Therefore, it is necessary to predict the state of the fault zone section to ensure the mechanical stability of the underground structure. Monitoring the size of joints and the porosity of the fillings is essential for rocks. Previous studies have not considered the variety of fillings in rock joints. In this study, electrical resistivity tests were conducted according to the particle mixing state of the sandy fillings. When the size of fillings is decreased at the constant porosity, the electrical resistivity tends to increase. The results of this study are expected to be useful as basic electrical resistivity data for predicting the ground conditions and evaluation of the ground behavior that is containing sandy fillings in the rock joint for tunnels.

Tunnel Behavior According to the Pillar Width (터널의 필러부 폭에 따른 터널거동)

  • Kim, Youngsu;Kwon, Taesoon;Jeong, Ilhan;Kim, Kwangil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.15-23
    • /
    • 2009
  • This research area is a greate section of triple tunnels that passes through the fault fractured zone the in the granite area. In this area, tunnel section, pillar width and overburden height are changed consecutively due to declivity of 1 : 4.5 and slope formation of upper part as changed section. That is, stability estimation for each section varying pillar width can be conducted because tunnel diameter changes gradually from 0.5D to 1.0D according to distance of pillar width. We have estimated the stability of pillar width in triple tunnels with monitoring value, and compared the stability with results of numerical analysis.

  • PDF

A Study on the Cause Analysis of the Ground Subsidence in Limestone Mine (석회석 광산에서 발생한 지반침하에 대한 원인 분석 연구)

  • Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.497-514
    • /
    • 2020
  • This study investigated the causes of large-scale ground subsidence in the upper part of mining cavities of the Samdo limestone mine, Samcheok city, Gangwondo, Korea. Geological and electrical resistivity surveys were undertaken on the collapsed slope of the mountain and in the mine tunnel where subsidence occurred, with geotechnical evaluations and numerical analysis. It is concluded that wide mining cavities, with irregular pillars in unstable rock masses hosting discontinuities, weathered over time, resulting in subsidence occurring along a fault plane due to increasing ground stress.

Development of Infrared Imaging Measurement Device for Internal Red Ginseng Analysis. (홍삼 내부 분석을 위한 적외선 영상 측정기기 개발)

  • Park, Jaeyoung;Kim, Taehoon;Jung, Seokhoon;Kim, Donggeun;Cho, Se-Hyoung;Han, Chang Ho;Lee, Sangjoon;Lee, Ji Yeon;Ko, Kuk Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.573-576
    • /
    • 2017
  • 본 연구는 홍삼 등급판정 과정에서 내부 조직 치밀도 분석을 위해 의료 영상 분석 방법을 이용하여 적외선 영상 측정기기를 개발하였다. 기존 홍삼 내부분석방법은 수동으로 암실환경에서 강한 조명을 홍삼에 투과하여 사람 눈으로 직접 판별하는 과정을 거친다. 이러한 기존 검사 과정은 작업 비효율성과 불균일한 검사기준으로 제품 품질 신뢰도 저하의 단점을 가져온다. 이러한 문제점을 해결하기 위해 본 연구는 적외선 조명환경에서 자동 측정이 가능한 홍삼 내부 측정기기를 개발하였다. 개발된 장치는 홍삼의 빛 투과 특성을 응용한 920nm 파장대역의 적외선 조명기구, 조명 제어회로, 적외선 대역 촬영이 가능한 영상 측정 카메라 장치, $0.9^{\circ}$의 간격으로 $360^{\circ}$ 홍삼 영상취득이 가능한 회전 엑츄에이터로 구성이 된다. 본 연구에서 제안 하는 홍삼 단층 영상분석 방법은, 홍삼을 $0.9^{\circ}$ 간격으로 회전시키어 $360^{\circ}$ 홍삼 내부영상을 취득하여 라돈 변환(Radon transform)을 통해 사이노그램(Sinogram)으로 재구성 하였으며, 역 라돈 변환(Inverse Radon transform)을 통해 단층 영상복원(Back-projection)알고리즘을 구현하였다. 이 결과 홍삼을 절단하지 않고 홍삼 내부 단면영상 획득이 가능하였으며 내공(內空), 내백(內白)의 유무를 판단하고 직경을 파악할 수 있었다. 이를 토대로 등급 판별 공식을 산출하면 신뢰성 있는 홍삼 등급 자동화 측정기기를 개발할 수 있을 것으로 기대된다.

Slope Failure Along the Weathered And Mobilized Foliation Plane : Studies for Causes of the Failure and the Supporting Methodologies (풍화된 엽리면을 따라 붕괴된 대절토 사면의 붕괴요인 분석과 보강방안에 대한 연구)

  • Hwang, Sang-Gi;Kim, Young-Muk;Ji, In-Taeg;Jeon, Byoung-Choo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.775-784
    • /
    • 2009
  • Weathered foliation could act as a critical failure plane because this type of plane tend to have low roughness and long extensions. A big constructed slope at $\bigcirc\bigcirc$ road construction site was failed due to the block movement along a fault zone which is parallel to foliation. Tectonic activity reactivated a fault zone parallel to foliation, and the fault clay within the shear zone metamorphosed retrogressively to chrolite. The failed block moved when the block weigh lost the balancing with the resisting force of the retrogressively metamorphosed chrolite. Evaluating the three dimensional distribution of the foliation was critical for establishing a plan for the stabilization of the slope. For this purpose, 10 boreholes were drilled as a lattice distribution, and the BIPS analyses are performed at each boreholes. The fractures measured in the boreholes are projected into 15 cross sections and their distributions are analysed, using Fracjection software. The projection analyse show that the strike of the foliation gets dipper towards left side of the slope. This geometry indicates that there are more failure block geometry at left side of the slope. Potential failure planes are searched using the projection method, and these information are provided for further support design.

  • PDF