• Title/Summary/Keyword: 단층촬영장치

Search Result 177, Processing Time 0.025 seconds

Relationship Between Type of Medical Institutions According to the Equipment List and Inspection Fee Computed Tomography (의료기관 종별에 따른 전산화단층촬영장비 보유현황과 검사료간의 관계)

  • Kim, Min-Cheol;Lim, Cheong-Hwan;Joo, Yeong-Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.315-322
    • /
    • 2014
  • This study demonstrates holding condition of CT by medical institution classification and by season, and examination fee in Korea currently to quantitatively understand frequency of examination region by change of CT equipment, domestic growing trend and change of distribution and using rate. Recent 10 years of CT holding condition by medical institution classification (Tertiary hospital, General hospital, Hospital, Clinic, Dental hospital, Dental clinic, Hospitalized health center) and by year (2003-2012), and CT examination fee of distribution of medical institution by year is surveyed. The holding ratio of Tertiary hospital level and General hospital level is 32.7% in 2003 and 33.0% in 2012. Whereas, Hospital and Clinic level is 74.2% in 2003 and 66.8% in 2012, which takes approximately 70%. Based on data in 2012, it is 82.2% of total examination fee in Tertiary hospital and General hospital, while 17.5% in hospital and clinic. CT holding rate of Hospital level is increasing, while Clinic level is decreasing. Approximately 80% of CT examination fee is claimed by Tertiary hospital and General hospital. Therefore, there is a significant correlation between CT holding condition of medical institution classification and examination fee. Particularly, correlation between CT holding number of Tertiary hospital and examination fee is significant (p<.001). The more CT holding number, the higher the amount claimed examination fee.

Estimation and Application of HU Values for Various Materials as a Function of Physical Factor (물리적 인자의 변화에 따른 다양한 구성물질의 하운스필드 단위 평가 및 응용)

  • Lee, Seung-Wan;Kim, Hee-Joung;Kim, Tae-Ho;Jo, So-Jeong;Lee, Chang-Lae
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.145-151
    • /
    • 2009
  • This study aims to evaluate CT (Computed Tomography) characteristics through the estimation of HU (Hounsfield Unit) and the corresponding variations using coefficient of variation values for various materials as a function of physical factor. HU values for various materials with varying densities as a function of physical factor were measured using MDCT (Siemens SOMATOM Sensation 4, Germany). The results showed that the HU values were decreased and increased as a function of kVp and material density, respectively. Especially, the HU values for bone and iodine at 140 kVp were 32% and 42% smaller than those at 80 kVp, respectively. In case of iodine, the HU values also decreased and increased as a function of kVp and concentration, respectively. While the HU values were fixed as a function of mAs. The decreased ratio of HU values between 80 keV and 140 keV was different at various concentration and maximum difference was shown as 1.73 at 3% concentration. These results indicated that it may be possible to separate composition of materials, e.g. iodine and bone, using single source CT. The results showed that dual energy techniques using single source CT can be applied to material separation and expand CT imaging techniques to other practical applications.

  • PDF

Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer (소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토)

  • Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyung;Wu Hong Gyun;Kim Dae Yong;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 1998
  • Purpose : This study is to evaluate the efficacy of small bowel displacement system(SBDS) in post-operative pelvic radiation therapy(RT) of rectal cancer patients by measurement of small bowel volume included in the radiation fields receiving therapeutic dose. Materials and Method : Ten consecutive new rectal cancer patients referred to the department of Radiation Oncology of Samsung Medical Center in May of 1997 were included in this study. All patients were asked to drink $Castrographin^(R)$ before simulation and were laid prone for conventional simulation and CT scans with and without SBDS. The volume of opacified small bowel on CT scans, which was to be included in the radiation fields receiving therapeutic dose, was measured using Picture archiving and communication system (PACS). Results : The average small bowel volumes with and without SBDS were 176.0ml(5.2-415.6ml) and 185.1ml(54.5-434.2ml), respectively The changes of small bowel volume with SBDS compared to those without SBDS were more than $10\%$ decrease in three, less than 10% decrease in two, less than $10\%$ increase in three, and more than $10\%$ increase in two patients. Conclusion : No significant advantage of using SBDS in post-operative pelvic RT for rectal cancer patients has been shown by small bowel volume measurement using CT scan considering additional effort and time needed for simulation and treatment setup.

  • PDF

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries (외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사)

  • Jahng, Geon-Ho;Yang, Dal-Mo;Sung, Dong-Wook;Lee, Kwang-Yong;Kim, Hyeog-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.276-284
    • /
    • 2008
  • A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

  • PDF

Digital Tomosynthesis Imaging of the Chest : Comparison of Patient Exposure Dose and Image Quality between Default Setting and Use Additional Filter (흉부 디지털토모영상의 기본모드 및 부가여과사용 시 환자선량과 화질비교)

  • Kim, Kye-Sun;Ahn, Sung-Min;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.9
    • /
    • pp.288-294
    • /
    • 2013
  • Chest digital tomosynthesis was the most advanced digital radiography technology, but it was higher patient dose than conventional chest radiography. Thus we tried to reduce a patient dose of chest digital tomosynthesis and evaluated its image quality. Result shows that radiation dose such as ESD, DAP and ED were 1.95 mGy, 17.66 $dGycm^2$ and 0.133 mSv respectively in default setting and 0.312 mGy, 2.27 $dGy.cm^2$ and 0.052 mSv in use additional filter, respectively. Doses were decrease 66.2%, 73.6% and 57.4% in ESD, DAP and ED, respectively. At the image quality assessment, overall sensitivities of use additional filter for nodule detection were not inferior to default mode for peripheral, central and peripheral micro nodules. However, sensitivity of low dose mode was significantly inferior to the default for central micro-nodules(p < .001).

Early-Stage Diagnosis of Cervix using the Polarization Sensitive Optical Coherence Tomography(A Preliminary Study) (편광 민감 광결맞음 단층 촬영 장치를 이용한 자궁경부의 조기 진단(A Preliminary Study))

  • Kang, Jin-Ho;Lee, Sang-Won;Yoo, Ji-Yeong;Kang, Moon-Sik;Kim, Beop-Min;Yoon, Bo-Sung;Kim, Young-Tae;Cho, Nam-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.367-372
    • /
    • 2007
  • Cervical dysplasia induces morphologic changes in the cervical epithelium which involve changes in the nuclear/cytoplasmic (N/C) ratio. Since the nucleus is one of the significant scattering sources, the N/C ratio change reflects the degree of circular polarization (DOCP) with the depth of signals. Therefore, we used the polarization-sensitive OCT (PS-OCT) technique to measure the polarization changes caused by scattering. Cervical tissues were obtained from a high-grade squamous intraepithelial lesion (H-SIL) of one woman and from low normal women. We obtained the mean of the DOCP as a function of depth in the cervix and quantified the change ratio of the DOCP using slopes that were determined by linear fits in the epithelium layer. We found that DOCP of H-SIL decayed faster than that of normal tissue because of the higher scattering in H-SIL as expected. This result indicates that the PS-OCT system might be useful in measurements of change ratio of DOCP with depth for screening of cervical dysplasia.

Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Noise Properties for Filtered Back Projection in CT Reconstruction (필터보정역투영 CT 영상재구성방법에서 잡음 특성)

  • Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.357-364
    • /
    • 2014
  • The filtered back projection in the image reconstruction algorithms for the clinic computed tomography system has been widely used. Noise of the reconstructed image was examined under the input noise for parallel and fan beam geometries. The reconstruction images of $512{\times}512$ size were carried out under 360 and 720 projection by the Visual C++ for parallel beam and fan beam, respectively, and those agreed with the original Shepp-Logan head phantom very much. Noise was generated because of intrinsic restriction (finite number of projections) for the image reconstruction algorithm, filtered back projection, when no input noise was applied. Because the result noise was rapidly increased under 0.5% input noise ratio, technologies for reducing noise in CT system and image processing is important.

Design of Cylindrical Magnetic Gradient field for NMR-CT (NMR-CT에서 원통좌표계를 구현하는 경사자계의 고안)

  • 이대행;이순칠
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.132-139
    • /
    • 1992
  • We have designed a magnetic field gradient useful for cylindrical imaging in NMR-CT. The direc¬tion of the designed field is parallel to the axis and the gradient in the radial direction of cylindrical coordinate is monotonically increasing. The ratio of the gradient in the radial and axial direction is greater than 10 near the center of coordinate. This ratio depends on solenoid length, the number of reverse current turns at center, and the amount of the reverse current. We built a gradient coil based on the numerical simulation and tested the field generated by NMR-CT. The resulting image matches with the theoretical expectation within 10% error. Since the data acquisition time of 1-D imaging is significantly shorter than 2-D imaging, it becomes possible to image much more dynamic objects by the use of this gradient field.

  • PDF