Pollutant Loading Estimate from Yongdam Watershed Using BASINS/HSPF (BASINS/HSPF를 이용한 용담댐 유역의 오염부하량 산정)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.187-197
    • /
    • 2006
  • A mathematical modeling program called Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency(EPA) was applied to the Yongdam Watershed to examine its applicability for loading estimates in watershed scale. It was run under BASINS (Better Assessment Science for Integrating point and Nonpoint Sources) program, and the model was validated using monitoring data of 2002 ${\sim}$ 2003. The model efficiency of runoff was high in comparison between simulated and observed data, while it was relatively low in the water quality parameters. But its reliability and performance were within the expectation considering complexity of the watershed and pollutant sources and land uses intermixed in the watershed. The estimated pollutant load from Yongdam watershed for BOD, T-N and T-P was 1,290,804 kg $yr{-1}$, 3,753,750 kg $yr{-1}$ and 77,404 kg $yr{-1}$,respectively. Non-point source (NPS) contribution was high showing BOD 57.2%, T-N 92.0% and T-P 60.2% of the total annual loading in the study area. The NPS loading during the monsoon rainy season (June to September) was about 55 ${\sim}$ 72% of total NPS loading, and runoff volume was also in a similar rate (69%). However, water quality was not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. Overall, the BASINS/HSPF was applied to the Yongdam watershed successfully without difficulty, and it was found that the model could be used conveniently to assess watershed characteristics and to estimate pollutant loading in watershed scale.

Analysis NPS Run-off Characteristics During Rainfall Event in upper Han-river Nae-Rin Cheon watershed (한강 상류 내린천 유역의 강우시 비점오염물질 유출특성 분석)

  • KI Cheol Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.471-471
    • /
    • 2023
  • 소양댐 상류 유역에 위치한 고랭지 밭에서 강우시 많은 양의 탁수가 유입되고 있어 상·하류지역사회에 갈등을 유발하고 하천 환경오염의 주범으로 지목되었다. 이에 환경부는 2007년부터 꾸준히 소양호 유역을 비점오염원 관리지역으로 지정하여 다양한 노력을 기울여왔으나 여전히 소양강 상류 수계의 강우시 흙탕물 발생이 지속적으로 문제가 되고 있다. 특히 고랭지 농업이 활발한 자운지구의 경우 고랭지 밭 경작 이외에도 나대지 상태로 방치되거나, 절삭지 보호가 제대로 이루어지지 않는 등 여러 가지 문제로 토사유출이 심각하게 발생하고 있어 흙탕물 관리가 필요한 실정이다. 이에 본 연구에서는 자운지구를 포함한 내린천 유역을 대상으로 강우유출수 모니터링을 수행하였으며, 모니터링 결과를 바탕으로 강우시 비점오염물질 유출 특성을 분석하였다. 강우유출수 모니터링은 2022년 3월부터 10월 중 총 5회를 수행하였으며, 내린천 유역 내 유량 측정망이 설치되어 있는 4개지점(양지교, 현리교, 하죽천교, 원대교)과 내린천 상류 2개지점(에코빌리지, 새터교) 총 6개 지점에서 강우유출수 모니터링을 실시하였다. 분석된 자료를 바탕으로 각 소유역별 EMC, 오염부하, 단위면적당 오염부하를 산정한 결과 하죽천교와 원대교의 단위면적 당 오염부하가 높게 나타났다. 이는 해당 소유역(내린천 하류)에서 발생한 강우강도가 상류에 비해 높았으며, 하죽천교는 유역내 농경지의 비율이 높고, 원대교는 가파른 경사도의 영향이 큰 것으로 판단된다. 또한, 하죽천교와 원대교 소유역에서 배출된느 흙탕물이 내린천 유역의 하천수질 오염에 상당한 기여를 하고 있는 것으로 나타났으며, 오염 우심 소유역에서 발생하는 흙탕물 저감을 위한 적절한 대책이 마련되어야 할 것으로 판단된다. 본 연구 결과와 같이 장기적인 모니터링을 통해 내린천 유역의 흙탕물 저감 대책 수립을 위한 기초자료로 활용할 수 있을 것으로 기대된다.

  • PDF

An Estimation of NPS Pollutant Loads using the Correlation between Storm Water Runoff and Pollutant Discharge in a Small Urban Drainage Basin (도시소유역에서의 유출과 비점원오염물 배출 간의 상관관계 수립에 의한 NPS 오염물 배출량의 산정)

  • 신현석;윤용남
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.85-95
    • /
    • 1993
  • Three purposes of this study are as follows: The first was the development of the extention method for the limited data observed in an urban drainage basin. The second was the analysis of the correlation between storm water runoff and NPS(non-point source) pollutant discharge, The last was the calculation of the monthly and annual specific NPS loads using the established correlation. the selected model was the SWMM monthly and annual specific NPs loads using the established correlation. The selected model was the SWMM (Storm Water Management model) developed by the US EPA(environmental Protection Agency). As a result of this study, the best correlation between storm wate runoff and NPS pollutants discharge was produced by the non-linear correlation between runoff rate(mm/hr)and specific loads rate(g/ha/sec)for all pollutants studied ; SS, COD, BOD, and TN. The best correlation through the analysis based on evently total mass was made by the linear correlation between the specific accumulated runoff(mm) and the specific accumulated loads(kg/ha) for CASE 1., and by the non-linear correlation for CASE 2. The NPS annual specific loads for the urban basin studied were 4933 kg/ha/year for SS, 775kg/ha/year for BOD, 3094kg/ha /year for COD,257kg/ha/year for TN, respectively. And the proportion of the NPS annual specific loads to the total annual specific loads were 42 % for SS, 13 % for BOD, 29% for COD, and 21 % for TN.

  • PDF

The Sidestream from WWTP; Its Characteristics and Effects on the Main Process (하수처리장(下水處理場)에서 반송수(返送水)의 성장(性狀)과 영향(影響))

  • Choi, Eui So;Lee, Ho Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.233-241
    • /
    • 1993
  • This study was conducted to characterise the sidestream from municipal wastewater treatment plants and its effects on the main treatment process. The flow rates and waste strengthes from each unit processes were measured and analysed, and finally determined its characteristics through the mass balance techniques. A laboratory scale completely mixed activated sludge was operated at $20^{\circ}C$ and fed in pulse with the sidestream to simulate the actual operating conditions. The study results indicated that the flow rates of sidestream ranged from 1.2 to 1.8 percent of the influent flow. However, the organic and nutrient loading rates could be increased to about 20 to 30 percent at an average, but 40 to 70 percent at a peak condition. It appears that the impurities from the sidestreams were not easily settled and resulted in lower primary efficiency. Consequently, it increased the organic loading rates to the aeration tank and the efficiencies were decreased at least about 10 percent at an average in comparison to the ordinary condition without the sidestream. With the peak condition, the efficiencies could not reach more than 80 percent for the organic removal and 50 percent for the nitrification.

  • PDF

Phosphorus and Suspended Solid Loading in Lake Yongdam (용담호 소유역별 인 및 부유물질 유입부하량 산정)

  • Kwon, Sang-Yong;Kim, Young-Geel;Yih, Won-Ho;Kim, Bom-Chul;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.322-333
    • /
    • 2005
  • Total phosphorus (TP) and suspended solids (SS) were measured in the discharge waters from 5 drainage basins of Lake Yongdam, from April, 2002 till March, 2004. The responses of SS and TP to rainfall were analyzed and their loadings into Lake Yongdam were calculated. The inflowing rivers into Lake Yongdam were the Juja River, the Jeongja River, the Jinan River, the Geum River and the Guryang River. Among these rivers Jinan River showed the highest TP that fluctuated very much according to the flow rate. TP and the flow rates (Q) of each river showed positive correlations with empirical relationsip of $TP\;=\;6.32Q^{0.30}$ for the Juia River, $TP\;=\;8.58Q^{0.49}$ for the Jeongia River, $TP\;=\;307.92Q^{0.10}$, for the Jinan River, $TP\;=\;17.91Q^{0.47}$, for the Geum River, $TP\;=\;20.11Q^{0.53}$ for Guryang River. In April 2002 ${\sim}$ March 2003, phosphorus loadings from the Juja River, the Jeongja River, the Jinan River, the Geum River and the Guryang River were calculated to be 3,677, 11,430, 36,412, 89,651, and 42,226 kgP ${\cdot}$ $yr^{-1}$ respectively. And the specific loadings from the Juja River, the Jeongia River, the Jinan River, the Geum River and the Guryang River were calculated to be 0.3, 2.9, 13.6, 9.3, and 13.0 kgP ${\cdot}$ $km^{-2}$ ${\cdot}$ $yr^{-1}$ respectively. In April 2002 ${\sim}$ March 2004, the suspended particles loading from the Juja River, the Jeongia River, the Jinan River, the Geum River and the Guryang River were 673, 1,232, 4,232, 30,902, 80,202 ton ${\cdot}$ $yr^{-1}$ respectively. The Guryang River showed the largest contribution of SS loading.

해외의 초고압송전선의 현상

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.1 s.3
    • /
    • pp.60-64
    • /
    • 1966
  • 송전거리와 송전전력의 증대에 따라 송전전압은 점차로 높아져 왔고 앞으로도 계속 높아질 것으로 보인다. 우리의 한국전력계통의 현재 최고 송전전압은 154Kv이지만 제 2차대전전에는 휴전선 이북의 220Kv 송전선을 운전했었고 앞으로 부하의 증가에 따라 계통용량은 점차로 커져서 단위기 용량의 큰 대용량 발전소가 계속 건설되어 송전전력이 증대할 것이므로 불원한 장래에 초고압송전선의 필요하게 될 것이다. 아래에서 해외 각국의 초고압송전선의 현황을 소개함은 우리 나라에서도 장차에 대비하여 이에 대한 더욱 활발한 조사연구활동이 있어야 될 것으로 믿고 이 자료가 많은 참고가 되리라고 기대하기 때문이다.

  • PDF

Modification of WASP5 for Ungauged Watershed Management and Its Application (미계측 유역관리를 위한 WASP5 모형의 개선 및 적용성 검토)

  • Kim, Jin-Ho;Shin, Dong-Suk;Kwun, Soon-Kuk
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • This study was carried out to develop a water quality simulation model for the evaluation of an ungauged watershed. For this purpose, the WASP5 model was selected and modified. The model consists of three sub-models, LOAD-M, DYN-M, and EUT-M. LOAD-M, an empirical model, estimates runoff loadings using point and non-point source data of villages. The Geum River Estuary watershed was selected to calibrate and verify the Modified-WASP5. The LOAD-M model was established using field data of water quality and quantity at the gauging stations of the watershed and was applied to the ungauged watersheds, taking the watershed properties into consideration. The result of water quality simulation using Modified-WASP5 shows that the observed average BOD data from Gongju and Ganggyeong were 2.6 mg/L and 2.8 mg/L, and the simulated data were 2.5 mg/L and 2.4 mg/L, respectively. Generally, simulation results were in good agreement with the observed data. This study focused on formulating an integrated model for evaluating ungauged watersheds. Even though simulation results varied slightly due to limited availability of data, the model developed in this study would be a useful tool for the assessment and management of ungauged watersheds.

Generation of Daily Load Curves for Performance Improvement of Power System Peak-Shaving (전력계통 Peak-Shaving 성능향상을 위한 1일 부하곡선 생성)

  • Son, Subin;Song, Hwachang
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.141-146
    • /
    • 2014
  • This paper suggests a way of generating one-day load curves for performance improvement of peak shaving in a power system. This Peak Shaving algorithm is a long-term scheduling algorithm of PMS (Power Management System) for BESS (Battery Energy Storage System). The main purpose of a PMS is to manage the input and output power from battery modules placed in a power system. Generally, when a Peak Shaving algorithm is used, a difference occurs between predict load curves and real load curves. This paper suggests a way of minimizing the difference by making predict load curves that consider weekly normalization and seasonal load characteristics for smooth energy charging and discharging.

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot - (강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 -)

  • Kang, Mee-A;Choi, Byoung-Woo;Yu, Jae-Jeong
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 2010
  • This study was carried out to produce the characteristics of pollutant loads caused by a cherry tree plot as a nonpoint sources(NPS) unit in agricultural areas. The relationship between rainfall and runoff didn't show a good coefficient with 0.5. Despite precipitation amount was less than 20 mm, runoff occurred with $0.5\;m^3$ because of high rainfall intensity of 8.8 mm/hr. In contrast, runoff was not occurred when precipitation amount was 47.4 mm in one case. In that case the primal effect on runoff was not precipitation amount. Correlation between load of pollutants such as BOD, COD, TN and TP and runoff' volumes showed significantly positive values which were more than r = 0.92 for all pollutants except SS(r = 0.71). SS could be a proper factor for estimating pollutant loads of BOD, COD, TN and TP because of a high correlation more than r = 0.73 between SS load and pollutant loads of BOD, COD, TN and TP. Both Organics and nutrient pollutants could be reduced if we control SS in runoff. The highest concentration of TN was detected in the event which was affected by fertilization activities directly. Therefore fertilization must be considered as a function of impact parameters on TN load in agricultural areas.

Design and Implementation of Spatio-temporal Power Load Analysis Model (시공간 전력부하분석모델 설계 및 구현)

  • Shin Jin-Ho;Yi Bong-Jae;Song Jae-Ju;Lee Jung-Il;Kim Young-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.537-540
    • /
    • 2006
  • 실세계의 복잡하고 종합적인 정보를 빠르고 효율적으로 분석 처리할 수 있는 지리정보시스템(GIS : Geographic Information System)의 효용성이 인식되면서 전력산업에서도 전국의 시설물 관리를 위해 수치지리정보를 구축하였다. 한편, 약 10만호의 고압고객을 대상으로 15분 단위의 전력사용량을 무선통신망을 이용하여 자동원격검침(AMR: Automatic Meter Reading)하고 있다. 본 논문에서는 산재된 대용량의 AMR 시계열성 데이터와 공간성을 지니는 전력설비 데이터를 이용하여 시각적 수요분석 및 공간적 분포특성 부하분석을 할 수 있는 새로운 활용모델을 개발하고 그 결과를 제시하고자 한다.

  • PDF