• 제목/요약/키워드: 단엽식

검색결과 9건 처리시간 0.022초

지지대 형상에 따른 단엽식 고분자 판막의 비선형 해석 (Nonlinear Analysis of the Monoleaflet Polymer Valve According to Shape of Supporting Members)

  • 한근조;안성찬;심재준;김성윤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.748-751
    • /
    • 2001
  • Monoleaflet polymer artificial heart valve was known to show remarkable improvement in antithrombosis and pressure drop compared with other type of artificial valve. In this investigation monoleaflet the vertical and horizontal deflection pattern of polymer heart valve with three types of supporting members straight member, and two curved members was analysed using the large deformation nonlinear finite element method.

  • PDF

지지대 형상에 따른 단엽식 고분자 판막의 비선형 해석 (Nonlinear Analysis of the Monoleaflet Polymer Valve according to Shape of Supporting Members)

  • 한근조;안성찬;심재준;김성윤
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.120-124
    • /
    • 2003
  • Monoleaflet polymer artificial heart valve was known to show remarkable improvement in antithrombosis and pressure drop compared with other type of artificial valve. In this investigation of monoleaflet heart valve the vertical and horizontal deflection pattern of polymer heart valve with three types of supporting members, straight member and two curved members were analysed using the large deformation nonlinear finite element method.

응력과 변형을 최소화하기 위한 단엽식 고분자 판막의 지지대 위치에 관한 연구 (A Study on the Location of Supporting Members in Monoleaflet Polymer Valve to Minimize Stress and Deformation)

  • 이성욱;심재준;한동섭;한근조;김태형
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.156-163
    • /
    • 2005
  • A monoleaflet polymer artificial heart valve showed the remarkable improvement in pressure drop compared with other types of artificial valve. So, in this study we designed a monoleaflet polymer artificial valve with two supporting members to minimize the deformation and bending stress of the valve with respect to the variation of the gap between two supporting members using nonlinear contact analysis. The marginal valve thickness was also predicted in accordance with the relationship between the thickness and horizontal displacement in order to prevent the dislocation of the valve tip from the frame wall.

응력 및 변위를 최소화하기 위한 단엽식 고분자 판막의 유한 요소 해석 (Finite Element Analysis of the Monoleaflet Polymer to Minimize Stress and Displacement)

  • 한근조;안성찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.85-92
    • /
    • 1996
  • 병변이 있는 판막을 대체하기 위하여 사용되는 인공판막으로는 기계식 판막, 고분자 판막 등이 있는데 고분자 판막이 기계식보다 항혈전성이 우수하므로 폴리우레탄을 이용하여 많이 연구되고 있다. 고분자 판막에는 단엽식, 삼엽식, 젤리피쉬식 등으로 제작되어 연구되고 있는데 이중 단엽식 판막은 제작이 가장 간편하고 심실내 씻김현상이 실제와 유사하며 혈류의 소용돌이 현상을 감소시킨다고 보고되고 있다. 혈압 강하를 감소시키기 위하여 고분자 판막의 두께를 얇게 할때 판막이 프레임 위 정상접촉 위치로 부터 탈구현상이 발생한다. 이것을 방지하기 위하여 2개의 지지대를 설치하여 판막의 수직변위를 최소로 하는 지지대 최적위치를 구하고, 그때 판막 끝의 수평 변위 및 판막에서의 응력분포상태를 구한 결과 최적위치는 지지대에 의해 나눠지는 3영역의 폭이 각각 6.2mm, 4.7mm, 5.1mm 일때 이고, 그때 최대 처짐이 0.19mm, 수평 최대변위가 0.047mm 이고 최대 주응력이나 등가응력의 최대치는 판막이 지지대가 접착되는 부위와 비접착 부위의 불연속점에서 발생하여 이 값들은 판막 각 영역의 폭이 커지면 증가함을 알았다.

  • PDF

단엽식 고분자판막의 모의순환실험 (In Vitro Test of a Monoleaflet Polymer Valve)

  • 김상현;김원기;장병철;조범구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.51-53
    • /
    • 1993
  • We have developed a monoleaflet polymer valve in order to be used as an inlet valve of the ventricular assist device, because it could help to improve the fluid dynamic characteristics in the ventricle. Mean systolic transvalvular pressure drops were measured for the monoleaflet polymer valve and their results were compared wi th that of the mechanical valve.

  • PDF

단엽식 고분자판막의 혈역학적 성능평가 (Hemodynamic Evaluation of Monoleaflet Polymer Valve)

  • 김상현;장병철
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.61-66
    • /
    • 1995
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane. To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medicals prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volllme and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

응력 및 변위를 최소화하기 위한 단엽식 고분자 판막의 설계 (Design of the monoleaflet polymer valve to minimize stress and displacement)

  • 한근조;김상현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.99-103
    • /
    • 1993
  • A monoleaflet polymer artificial heart valve which showed the remarkable improvement in pressure drop compared with other types of artificial valve was designed to decrease the deflection in vertical direction and the displacement or the valve tip in horizontal direction. Stress distribution change was studied as the location of the supporting members or the valve frame changed. And it was found that using the valve tip horizontal displacement the minimum valve thickness could be obtained in order to prevent the gap between the valve tip and the frame wall.

  • PDF

고분자판막의 동물실험 및 생체내 혈액적합성 연구 (Animal Experiment and Blood Biocompatibility Study of Polymer Valve)

  • 김상현;홍유선
    • Journal of Chest Surgery
    • /
    • 제30권4호
    • /
    • pp.357-362
    • /
    • 1997
  • 심실보조장치 등의 단기간 사용을 위하고 경제적이고 항혈전성이 높은 판막을 개발하기 위해 고분자 판막을 연구 중인데 판막의 혈액적합성을 시험하기 위해 동물실험을 시행하였다. 고분자판막은 외경이 각각 22 mm, 18 mm, 16 mm인 단엽식 판막이다. 열림판과 프레 임 모두 재질을 폴리우레탄 계로 제작하 여 유연하고 완전한 접착이 되도록 하였다. 총 7 마리의 황견에 이식하였는데 이식 위치에 따라 3가지로 분류하였다. 첫 번째는 심실보조장치의 유입구에 삽입하였고,두 번째는 대동맥에,세 번째는우심실과 우심방사이에 인조혈관을 이용하여 이식하였다. 가장 긴 생존 기간은 20일 이었다. 판막의 항혈전성 및 용혈현상을 입증하기 위 해 헤모글로빈, 헤마토크리트, 적혈구수, 백혈구수, LDH, 혈색소 등을 검사하였 다. 본 연구는 좀 더 개선하면 고분자판막이 심실보조장치에 단기간 사용 가능한 판막이 될 수 있는 가능성을 보여주었다.

  • PDF