• Title/Summary/Keyword: 단열 효율

Search Result 206, Processing Time 0.024 seconds

A Numerical Study on the Natural Convection from Two Isothermal Square Beams Attached to an Vertical Adiabatic Plate (수직단열판에 부착된 2개의 등온 사각비임에서의 자연대류 열전달에 관한 수치 해석)

  • Park, Jae-Lim;Bae, Dae-Sok;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 1991
  • A Steady laminar natural convection heat transfer from two isothermal square beams attached to a vertical adiabatic plate has been studied numerically. The results have been obtained for dimensionless beam spacings, $0.5{\le}D/L{\le}3.0$, and for Gr=5000-10000 at ${\phi}_2/{\phi}_1=1.0$. 1. The local Nusselt number from the beam surface is increased with the dimension-less beam spacing D/L. but that of the downward surface of the lower beam is almost same as the D/L increases. And, the local Nusselt number from the upward surface of a lower beam is greatly increased with D/L. 2. The beam spacings of the maximum mean Nusselt number for the downward surface of an upper beam and the upward surface of a lower beam occur at. D/L =2.6 and 2.0 respectively. 3. The beam spacing for the maximum total mean Nusselt number occurs at D/L = 2.6.

  • PDF

Multi Layer Thin Film Deposition Using Rotatable Hexagonal Gun by Sputtering for the Insulating Glass

  • Park, Se-Yeon;Lee, Jong-Ho;Choi, Bum-Ho;Han, Young-Ki;Lee, Kee-Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.314-315
    • /
    • 2012
  • 최근들어 반도체 및 디스플레이 소자의 구조가 복잡해짐에 따라 다층 박막 증착에 대한 중요성이 날로 증가하고 있다. 본 연구에서는 다층 박막을 효율적으로 증착하기 위해 회전이 가능한 육각건을 개발하였고, 이를 이용하여 에너지 절약형 단열 유리 증착 공정을 구현 하였다. 개발된 회전형 육각건은 기존 플래너형 스퍼터링 건의 확장형으로서 최대 6개의 물질을 하나의 챔버에서 증착이 가능하도록 구성되었다. 기존 공정의 경우 서로 다른 물질 증착을 위해서는 각각의 챔버가 필요한 반면, 회전형 육각건을 이용할 경우 하나의 챔버에서 공정을 진행할 수 있어 원가 절감이 가능하다. Fig. 1은 개발된 회전형 육각건의 모식도로서, 스퍼터링 타겟이 장착 가능한 건과, 회전부로 구성되어 있다. 이를 이용하여 투명전극-금속-투명전극-금속-절연체로 구성되어 있는 에너지 절약형 단열 유리용 다층 박막 증착 공정을 개발하였다. 이때 알루미늄이 도핑된 ZnO (AZO)는 RF 마그네트론 스퍼터로, 금속 박막은 DC 스퍼터, $SiO_2$ 및 SiN과 같은 절연 박막은 $O_2$$N_2$ 분위기에서 반응성 RF 스퍼터로 각각 증착하였다. Base pressure는 $10^{-7}$ torr였으며, 증착 시 공정 압력은 1~3 mTorr로 조정하였다. 증착 균일도 향상을 위해 20 rpm의 속도로 기판을 회전시켰다. Fig. 2(a)는 ZnO-Ag-ZnO 구조로 이루어진 다층 박막의 단면을 관찰한 투과전자 현미경 사진으로 각 층간의 계면이 뚜렷하게 나타남을 확인할 수 있으며, 각 층간의 intermixing 현상이 발생하지 않음을 확인 가능하다. 이를 보완하기 위해 Fig. 2(b)에서 보는 바와 같이 XPS를 이용하여 depth profile을 측정하였다. 각 층에서 서로 다른 물질이 발견되는 현상, 즉 교차 오염이 발생함에 따라 나타나는 intermixing 없이 거의 순수한 형태의 ZnO, Ag 박막 성분이 검출되었다. 이는 6개의 서로 다른 물질이 장착된 회전형 육각건을 이용하여 고 품질의 다층 박막 증착이 가능함을 제시하는 결과이다. 증착된 다층 박막의 균일도는 3.8%, 가시광선 영역에서 80% 이상의 투과도, 면저항 값은 3 ${\Omega}/{\Box}$ 이하를 보임으로서 에너지 절약형 단열 유리로서의 사양을 만족시키는 결과를 제시하였다.

  • PDF

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

A thermal-flow analysis of deaerator floor of power plant for reducing the radiative heat transfer effect (발전소 Deaerator floor의 복사효과 저감을 위한 열유동 해석)

  • Kim, Tae-Kwon;Ha, Ji-Soo;Choi, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.476-481
    • /
    • 2016
  • Steam power generation is used to produce electricity through a generator that is connected to a steam turbine. As a result, the surface temperature of the deaerator is $70^{\circ}C$during the summer season, the surface temperature of the storage tank is $67^{\circ}C$, and the air temperature is $50^{\circ}C$. This environment is inappropriate for workers and instruments. Workers adjacent to the deaerator and storage tank in particular feel higher temperatures because of the radiative heat transfer effect. Therefore, we optimized the cooling conditions by computational analysis. Case 1 is the current shape of the power plant, Case 2 has additional insulation, and Case 3 has a radiation shield. Flow is caused by a temperature difference between the heat sources in the wall, and hot air is trapped in the right upper end. Based on the temperature contours and the maximum temperature of the surfaces, Case 2 was found to be the most efficient for reducing radiative heat transfer effects.

Heat Transfer Characteristics under Recirculation zone of Ramjet Combustor (재순환 영역이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Lee, Keon-Woo;Oh, Min-Keun;Ham, Hee-Chul;Hwang, Ki-Young;Cho, Hyung-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-17
    • /
    • 2007
  • This experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

Development of SOFC stack module (SOFC 모듈평가장치 기술개발)

  • Choi, YoungJae;Lee, InSung;Jun, JoongHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.81.2-81.2
    • /
    • 2010
  • 고체 산화물 연료전지(SOFC) 시스템은 스택과 기계적 주변 장치인 MBOP(Mechanical Balance of Plant), 그리고 전기적 주변장치인 EBOP(Electrical Balance of Plant)로 구성되어있다. SOFC는 일반적으로 $700^{\circ}C$ 이상의 고온에서 작동되기 때문에 효율적인 열 이용 및 열 관리가 중요하다. SOFC 시스템의 MBOP에는 상온의 연료가스들을 고온으로 가열하여 스택에 유입 시기키 위한 열교환기 및 촉매연소기 등의 장치들이 필요하며, 효율적인 열관리를 위해서는 고온에서 작동하는 장치들을 한곳에 통합하여 구성하는 것이 필수적이다. 본 연구에서는 SOFC 시스템의 MBOP(Mechanical Balance of Pant) 중 고온부에 해당하는 촉매연소기, 열교환기 및 스택이 통합된 스택 모듈을 제작에 앞서 개념 검증을 위해 열교환기 및 촉매연소기로 이루어진 프로토타입(prototype)의 SOFC 모듈평가 장치를 제작하였다. 열교환기는 Plate형으로 총 6개로 구성되어 있으며, 연료극과 공기극 가스라인에 각각 3개씩 배치하여 스택에 유입되는 연료 및 공기가 촉매연소기에서 나오는 고온의 배가스와 열교환되어 가열되도록 구성하였다. 촉매연소기는 honeycomb 타입의 촉매를 사용하였고, 촉매연소기로 유입되는 연료극 배가스와 공기의 균일혼합과 hot spot을 방지하기 위한 장치를 삽입하여 제작하였다. 제작된 SOFC 모듈평가장치는 시운전을 통해 각 장치의 성능 확인 후 반응면적이 $20{\times}20cm^2$ 인 단전지를 적층하여 연계 운전을 수행하였다.

  • PDF

A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating (건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony (발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

A Study on the Analysis of Building Energy Rating considering the Region (지역에 따른 주거용 건물에너지효율등급 분석 연구)

  • Ahn, Byung-Lip;Kim, Chi-Hoon;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope (외피 열성능에 따른 건물에너지효율등급 분석 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.59-64
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.