• Title/Summary/Keyword: 단열 조

Search Result 100, Processing Time 0.021 seconds

Geochemical Characteristics of the Gyeongju LILW Repository II. Rock and Mineral (중.저준위 방사성폐기물 처분부지의 지구화학 특성 II. 암석 및 광물)

  • Kim, Geon-Young;Koh, Yong-Kwon;Choi, Byoung-Young;Shin, Seon-Ho;Kim, Doo-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.307-327
    • /
    • 2008
  • Geochemical study on the rocks and minerals of the Gyeongju low and intermediate level waste repository was carried out in order to provide geochemical data for the safety assessment and geochemical modeling. Polarized microscopy, X-ray diffraction method, chemical analysis for the major and trace elements, scanning electron microscopy(SEM), and stable isotope analysis were applied. Fracture zones are locally developed with various degrees of alteration in the study area. The study area is mainly composed of granodiorite and diorite and their relation is gradational in the field. However, they could be easily distinguished by their chemical property. The granodiorite showed higher $SiO_2$ content and lower MgO and $Fe_2O_3$ contents than the diorite. Variation trends of the major elements of the granodiorite and diorite were plotted on the same line according to the increase of $SiO_2$ content suggesting that they were differentiated from the same magma. Spatial distribution of the various elements showed that the diorite region had lower $SiO_2,\;Al_2O_3,\;Na_2O\;and\;K_2O$ contents, and higher CaO, $Fe_2O_3$ contents than the granodiorite region. Especially, because the differences in the CaO and $Na_2O$ distribution were most distinct and their trends were reciprocal, the chemical variation of the plagioclase of the granitic rocks was the main parameter of the chemical variation of the host rocks in the study area. Identified fracture-filling minerals from the drill core were montmorillonite, zeolite minerals, chlorite, illite, calcite and pyrite. Especially pyrite and laumontite, which are known as indicating minerals of hydrothermal alteration, were widely distributed in the study area indicating that the study area was affected by mineralization and/or hydrothermal alteration. Sulfur isotope analysis for the pyrite and oxygen-hydrogen stable isotope analysis for the clay minerals indicated that they were originated from the magma. Therefore, it is considered that the fracture-filling minerals from the study area were affected by the hydrothermal solution as well as the simply water-rock interaction.

  • PDF

The Hydration Heat of High Strength Concrete (고강도 콘크리트의 단열온도상승에 관한 실험적 연구)

  • 노재호;한정호;조일호;박연동;정재동;김진근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.209-214
    • /
    • 1994
  • The heat of hydration of cement causes the intemal temperature rise at early age, particulay in massive concrete structures. As the results of the temperature rise and restraint condition, the thermal stress amy induce cracks in concrete. The prediction of the thermal stress is very important in design and consturction slages in order to control the cracks in mass concrete. In this study, the temperature rise of high strength concrete due to the heat of hydration is investigated. Test variables are type and content of binder. As the results, the temperature rise is imcreased with increasing cement content. However, the increament is decreased in higher cement comtnet range. Fly ash is effictive in the reduction of hydration heat.

  • PDF

마찰특성이 미소절삭기구에 미치는 영향에 관한 연구

  • 황준;남궁석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.166-171
    • /
    • 1993
  • 절삭공구에의한 절삭가공은 오늘날 가장 보편화된 가공기술중의 하나이다. 그런데, 최근들어 각종 첨단산업의발전과 함께 초정밀 부품제작이 필수선결 조건으로 부상하고 있으며, 이에대한 해결방안중의 하나로 초정밀가공 기 술로 크게 대두되고 있다. 최근 컴퓨터 기술의 발달에 따라 구조해석분야의 해석방법론의 개발 및 보완에 힘입어 Klemecki(1973)에 의해유한요소법을 이용한 Chip생성기구 해석에 관한 연구가수행되었으며, Stevenson(1983) 등에의해단열조 건하에서 변형률과 온도 상태에서의 Chip형상, 잔류응결-변형율에 대한 연구가 이루어졌다. 본 연구에서는 유한요소법을 이용하여 미소절삭기구를 모델링하고, 절삭인자규명을 중심으로 응력-변형률 해석을 실시함으로써, 미소절삭시의 Chip 생성기구 및 전단면 생성 원리, 공구와 Chip간의 마찰기구의 고찰을 통해기본 Mechanism 이해와 적절한 절삭유한요소모델 제시의 기초자료로 삼고자 한다. 특히 본 보고서에서는 미소 절삭기구의 적정한 Constitutive Deformation Law 마찰계수 등 주요절삭인자변경에 따른 미소절삭기구 해석에 주안점을 두어 연구한 결과를 기술하였다.

Development of a Thermoelectric Dehumidifier (열전식 제습기 개발)

  • 주해호;이재원;이화조;권도중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.753-757
    • /
    • 1996
  • 연전식 제습기는 제습판과 발열판, 열전식 열펌프, 팬과 모타, 직류 전원공급 장치로구성되어 있으며, 열전식 열펌프에 직류전원을 공급하면 고온면과 저온면이 발생하는 데 저온면의 온도룰 로점온도 이하로 냉각하여 공기중에 있는 수분을 제거하는 원리를 이용한 것이다. 초기 단계로 개발된 열전식 열펌프를 이용한 열전식 제습기(TED-92)는 기계식 제습기에 비하 여 제습효율이 너무 낮기 때문에, 본 연구에서는 여러 문제점을 개선하는 방법으로 열전식 열펌 프의 선정, 핀 설계, 제습기의 설계 등을 중점적으로 개선하여열전식 제습기 (TED-95)를 개발하 였다. 여러가지 방법으로 실험한 결과, 열전식 열펌프 CP1.4-127-045L 2개를 사용하여 발열판의 크기를 300 mm로 하여 단열재를 사용하지 않고 입력 전류를 4A를 입력하였을 때 단위전력당 제 습량이 가장 많았다. 열전식 제습기와 기계식 제습기를 비교실험 해본 결과, 열전식 제습기가 기 계식 제습기에 비해 약 21%의 제습효율을 나타 내었다. 그러므로 초기의 열전식 제습기 (TED-92) 보다 약 2배의 제습효율을 높였다.

  • PDF

An Experimental Study on Thermal Resistance of Large-scale Specimen Using KS F 2278 (KS F 2278을 적용한 대면적 시료 열관류율 시험 실측에 관한 연구)

  • Moon, Jae-Sik;Lee, Won-Gyun;Kim, Young-Bong;Cho, Byoung Young;No, Sang-Tae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.306-307
    • /
    • 2018
  • In Korea, The thermal resistance test of window sets is performed according to KS F 2278 standard, and is performed only on a specimen size of 2000 × 2000 (mm). In this study, a standard panel measuring 4000 × 3000 (mm) size was used to measure the heat flux in each part of the specimen, and to calculate the resistance to heat transfer And to seize whether the KS F 2278 standard is applicable to large Specimen.

  • PDF

가스발생기 뒷마개부의 열/구조 해석

  • 구송희;이방업;조원만
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.265-272
    • /
    • 1996
  • 액츄에이터에 사용되는 터어보 펌프의 터어빈을 구동시키기 위한 가스발생기용 고체연료 추진기관의 뒷마개부에 대하여 열/구조 해석을 수행하였다. 가스발생기는 장시간 연소모타로써 뒷마개에는 단열이 되어 있지 않은 배출튜브가 나사로 체결되어 고온, 고압의 연소가스에 의해 뒷마개 구조물에 작용하는 열 하중이 상당히 클 것으로 판단되므로, 최적설계를 위하여 뒷마개부의 열 및 구조해석을 수행하여 열하중의 영향을 예측하고 경량화를 위한 설계자료를 얻고자 하였다. 본 논문에서는 해석결과만을 언급하였으며 차후에 수행될 지상시험시에 해석치와 실험치를 비교한 후 좀 더 정확히 모델링을 하여 열/구조 해석 결과를 뒷마개부의 최적설계에 활용하고자 한다. 해석 결과 열하중이 연소관과의 조립부에는 거의 영향을 주지 않았으나, 열과 압력하중이 동시에 작용할 경우에 뒷마개 배출튜브의 조립부 근접한 곳에서 항복응력을 넘는 응력이 발생하여 정확한 구조 해석을 위해서는 탄소성해석을 수행하여야 할 것으로 판단된다.

  • PDF

A Comparative Study on the Thermal Performance Changes by the Insulating Construction Types of Exterior Walls in Residential Buildings (주거용(住居用) 건물(建物) 외벽(外壁)의 단열공법별(斷熱工法別) 열성능(熱性能) 변동(變動)에 관한 비교(比較) 연구(硏究))

  • Kim, Moon-Han;Cho, Kyun-Hyong;Kim, Kwang-Woo
    • Solar Energy
    • /
    • v.8 no.1
    • /
    • pp.22-32
    • /
    • 1988
  • It is known that the energy consumption and indoor thermal comfort in residential buildings are affected by the thermal performance of building envelopes. The thermal performance of building envelopes varies with their design methods. In this study, the thermal performance changes by the insulating construction types of exterior walls were analyzed, 1) by varing the thickness of the insulation 2) by varing the location of the insulation 3) by varing the location of the plane airspace The analyzed results are presented and the thermal performance evaluating factors were compared and discussed.

  • PDF

Shear Resistance of Light-gauge Steel Stud Wall infilled with light-weight foamed mortar (경량기포모르터와 합성한 경량형강 벽체의 전단 저항)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.397-406
    • /
    • 2004
  • This paper presents the test and evaluation results on the shear strength and stiffness of a light steel stud wall from a lightweight foamed mortar (lightweight hybrid wall). The use of a lightweight foamed mortar was aimed at improving structural performance, thermal performance, and finish. Studiesshowed that it did not affect thermal performance, but it contributed to structural performance and finish when the unit weight was more than 0.8 (Editor's note: Please indicate the unit of measurement.). In this study, 14 specimens-whose parameters included the specific gravity of the lightweight foamed mortar (0.6, 0.8, 1.0, 1.2), the spacing of the stud (450 mm, 600 mm, or 900 mm), finishing materials (such as lightweight foamed mortar, OSB, and gypsum board), and bracing-were manufactured. Three typical, steel house-framing specimens were added to compare the test results with the 14 specimens. The results of in-plane shear tests show that the use of lightweight foamed mortar (1.15~5.38 times stronger, 1.45~13.7 times stiffer) results in ultimate strength and initial stiffness. In addition, it was possible to widen the stud spacing to up to 900 mm without decreasing shear strength. It was very important to prevent the lightweight foamed mortar from shrinking and to secure the adhesion between the steel stud and the lightweight foamed mortar to improve structural performance.

A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion (압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구)

  • Jung, Yun Jin;Kwon, Young Bong;Kwak, Myong Keun;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.543-551
    • /
    • 2006
  • Cold-formed steel studs that are being used as load-bearing members of wall panels for steel houses have a problem with their insulation due to the heat bridging of their web. Some additional thermal insulating materials should be used. To solve this problem, the new-concept hybrid stud, which consists of a galvanized steel sheet (t = 1.0 m - 12.0 m) and a GFRP panel (t = 4.0-6.0 mm), has recently been developed. An investigation on the structural behavior and the strength capacity of this new hybrid stud has been conducted so that it can be used in load-bearing wall panels of residential buildings. This paper describes the axial compression-torsion test results of the hybrid studs under both axial compression and torsion using ATTM. The main factors of the test were the stud length, the magnitude of the initial compressive force, and the loading method of the monotonic or cyclic loading. The torsion was applied increasingly while the initial compression was kept constant to the failure of the hybrid section. The advanced analysis results obtained form the finite element procedure that considered the material properties of the high-strength galvanized steel and the GFRP were compared with the test results for verification.