• Title/Summary/Keyword: 단열 시스템

Search Result 218, Processing Time 0.023 seconds

Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling (그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구)

  • Kim, Woong-Hoi;Kang, Eun-Ho;Yoon, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Supervisor System Development for Improving Quality of RFID Cold Storage Management Systems (RFID 냉동창고 관리시스템의 품질향상을 위한 슈퍼바이저 시스템 개발)

  • Moon, Mi-Kyeong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.109-117
    • /
    • 2014
  • A cold storage is a warehouse of a insulated building with cooling installations. It has many different types of cold rooms with temperatures below 0 degrees Celsius, and the sequential workflow such as receiving, picking and packing runs in that rooms. Recently, the cold storages have adopted RFID technology, and consequently, warehouse product management in them are becoming intelligent and network. However, information inconsistency in warehouses caused by physical and logical errors reduces reliability in the RFID cold storage management system and worsens their work efficiency. Therefore, it is necessary to develop an early detection system to identify errors. In this paper, we suggest a supervisory system detecting logical errors on business processes of the RFID cold storage. It is composed of a master supervisor and mobile supervisor. In the master supervisor, the manager can set the constraints conditions and get alerts, and in the mobile supervisor, the workers confirm and deal with these faults directly. The supervisory system improve reliability of the RFID cold storage management system by recognizing a failure to identify physically and logically using these constraint conditions. This paper shows that the supervisory system can reduce the average recovery time to improve reliability by decreasing the time for detecting and analyzing errors in the RFID cold storage management system.

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.

자성유체 윤활제의 개발 동향

  • 김영규;심우전;김청균
    • Tribology and Lubricants
    • /
    • v.12 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • 자성유체는 자연에서 추출한 것이 아니라 자화성(Magnetizability)과 유도성(Flowability)을 동시에 갖도록 합성한 특수액체이다. 자성유체는 1960년대 중반에 미국의 NASA에서 처음 개발된 이후로 윤활, 밀봉, 감쇄, 의료 등의 분야에서 응용연구가 많이 진행되었기 때문에 고도의 정밀도를 요하는 항공, 우주산업, 컴퓨터와 반도체 분야 등에서 실용화가 크게 진전되고 있다. 특수물질일 자성유체는 전기적으로 도체인 10nm 정도의 미세한 자기입자(Magnetic particles)에 코팅을 한 후, 이것을 물, 탄화수소, 플루오르카본, 에스터 등의 매개유체(Carrier Fluids)에 혼합시켜서 콜로이드 상태로 사용하게 된다. 자성유체는 미세한 자기입자들이 매개유체내에서 서로 충돌하면서 반발력을 발생시켜서 상호간에 늘 콜로이드 상태를 유지하고 있으며, 이 특수유체가 자기장의 영향을 받게 되면 점도가 증가하면서 특이한 성질을 갖게 된다. 상대 접촉 운동면에 경계마찰이나 혼합마찰을 하게 되면 윤활상태는 비교적 나쁘다. 이러한 마찰지역에 콜로이드상의 자성유체 윤활제를 공급하면 기존의 윤활제에 비하여 대단히 효과적으로 윤활을 할 수 있게 된다. 그러나 자성유체 윤활제가 마찰부위에 원활하게 공급하기 위해서는 미끄럼 마찰부에서 자기장을 잘 형성시킬 수 있는 도체이어야 하기 때문에 특별한 윤활 시스템 설계가 제시되어야 한다. 자성유체 윤활제는 합성으로 제조된 특수물질로 여러가지 장점을 갖고는 있으나 기존 윤활유와의 적합성, 마찰열, 밀봉압력 등의 조건에서 제한적으로 사용될 수 밖에 없으므로 항공, 우주 산업이나 석유 화학분야와 같이 특수 환경에서만 사용되고, 또한 기존의 광유계 윤활제에 비하여 대단히 고가하는 문제점을 갖고 있다. 그러나 윤활 마찰면의 다양화와 가혹한 사용조건은 자성유체 윤활제의 연구개발 필요성을 크게 증대시키고 있다.xed Effects Model)을 결정하고, 각각에 해당하는 통계모형을 구축하였다. 이 결과 (1) 업종 및 기업규모별로 그룹간에 유의한 특성이 발견되었으며, (2) R&D 및 광고투자는 기업의 시장성과를 설명하는 중요한 변수이나, (3) R&D 투자의 경우는 광고에 비해 불확실성이 존재하는 것으로 나타났고, (4) 수리모형에서 도출된 한계원리가 통계모형에서도 유효한 것으로 드러났다.등을 토대로 한 10대 산업을 육성하기 위하여 과학기술부는 기술수요조사를 바탕으로 49개 주요기술을 도출하여, 과학기술 일류 국가 실현, 국민소득 2만불 달성이라는 국가적 슬로건을 내걸고 “차세대 성장동력” 창출을 위한 범정부차원의 기획과 연구비의 집중투자를 추진하고 있다.달성하기 위해서는 종합류류 전산망의 시급한 구축과 함께 화물차의 적재율을 높이고 공차율을 낮출 수 있는 운송체계의 수립이 필요한 것으로 판단된다. 그라나 이러한 화물전용차선의 효과는 단기적인 치유책일 수밖에 없기 때문에 물류유통 시설의 확충을 위한 사회간접자본의 구축을 서둘러 시행하여야 할 것이다.으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of cocoon. It is equal to 9% increase in index, as compared to that of control. In case

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

The Treatment of Volatile Organic Compounds Using a Pilot-Scale Biofilter (Pilot 규모의 바이오필터를 이용한 휘발성유기화합물질 제거)

  • Son, Hyun-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Two biofilter tests were conducted under different operating conditions. Test # 1 was performed to treat VOCs generated from a paint booth. The second test was performed to treat VOCs generated from chemical manufacturing processes. The volume of biofilter media was 4.3 $m^3$. For the test # 1, the biofilter was operated for 30 days with 99.9% reduction ratio. Range of temperature of each stage of the biofilter media was measured between $34^{\circ}C$ and $73^{\circ}C$. All the temperatures of stages reduced gradually after the initial dramatic increase. For the test # 2, the biofilter experiment was conducted for 14 days. In this case, the biofilter was installed outdoor and the experiment was performed during wintertime. Therefore, temperature management for the biofilter was needed. Seven-centimeter thick fiberglass insulation and $150^{\circ}C$ steam heating were used to overcome the outside freezing cold weather during test # 2. Temperature of stage # 5 was measured the highest and that of stage # 1 was the lowest. More acclimation time and test period was needed to determine the maximum loading rate.

A Transit Trip Assignment Model Under Capacity Restraint (용량을 고려한 대중교통 통행배정모형 구축에 관한 연구)

  • 윤혁렬
    • Proceedings of the KOR-KST Conference
    • /
    • 2001.02a
    • /
    • pp.3-29
    • /
    • 2001
  • 본 연구에서는 기존의 대중교통 통행배정모형이 고려하지 않거나 미흡하게 반영하였던 차량과 노선의 용량제약을 고려한 모형의 구축을 시도하였다. 일반적으로 대중교통 통행배정에서 수요와 공급의 관계는 수요가 증가하는 것과 무관하다고 받아들여지고 있으나 용량 초과는 통행자들의 경로선택 및 수단선택에 영향을 끼친다고 볼 수 있다. 이러한 용량초과에 의한 혼잡을 반영하기 위해 용량제약식을 포함한 모형을 개발하고 실용운행회수라는 개념을 도입하였다. 또한 기존에 제시된 용량제약을 고려한 모형들이 실제적인 현상을 정확히 모사하는 데에는 한계가 있을 뿐 만 아니라 현실과 다소 거리가 있는 가정이 내재되어 있는 반면 본 연구에서는 가능한 한 최대로 현실 여건을 반영하는 모형을 정립하였다. 본 연구에서 제시한 모형은 동일한 기종점 사이를 운행하는 경쟁노선이 많은 대도시에서 통근·통학을 위한 통행자들이 많은 오전, 오후 첨두시 대중교통 수요를 분석하여 대중교통의 운행관리체계 개선 및 투자계획, 서비스 개선을 위한 수요예측을 하는데 유용하게 사용할 수 있을 것으로 사료된다. 그리고 기존의 대중교통 통행배정의 결과가 현재나 장래의 잠재적인 수요(demand)를 예측하는 방법인데 반하여 본 연구에서 정립된 모형은 주어진 네트워크에서 실제로 통행하고 있는 수요(flow)를 예측함으로써 교통 계획가나 대중교통 운영자의 계획 및 운영정책수립에 합리적인 도움을 줄 수 있다. 또한 현재의 대중교통 시스템 하에서의 통행배정 뿐만 아니라 다른 형태의 용량과 운행특성을 가진 교통 수단이나 노선이 도입되었을 때 공급이 제한적인 경우의 수요 예측에 적합한 모형을 개발하였다.에 대한 규제가 초국가적 차원으로 발전되는 계기를 제공하고 있다. 향후, 담배규제협약안의 세부사안들에 대한 합의과정에서 각 국별로 상당한 이견과 반발이 예상되고 있지만, 협약안의 전체 회원국 투표에서 승인될 경우 각 국가들뿐만 아니라 담배산업과 담배기업들에게 미치는 파급효과가 매우 클 것으로 예상된다. 대부분의 국제협약들이 그러하듯이, 담배규제협약도 그 적용 범위와 수준이 어느 정도로 결정되는지에 따라 각 국가와 기업별 이해관계가 크게 달라지게 되기 때문에 신중한 대응전략이 요구된다고 하겠다.의 화물전용차선의 설치시는 수답렬 교통량의 구성비와 구간 평균교통량에 의하여 그 효과가 다르게 나타남을 알 수 있었다. 따라서 물류비용 절감차원에서의 화물전용차선의 설치는 본 연구에서 나타낸 방법과 같이 수단간의 경제적 편익을 고려한 구간별 시간대별 효과분석을 통하여 정책의 시행여부가 결정되어야 할 것이다. 한편, 화물전용차선의 설치로 인한 물류비용의 절감을 보다 효과적으로 달성하기 위해서는 종합류류 전산망의 시급한 구축과 함께 화물차의 적재율을 높이고 공차율을 낮출 수 있는 운송체계의 수립이 필요한 것으로 판단된다. 그라나 이러한 화물전용차선의 효과는 단기적인 치유책일 수밖에 없기 때문에 물류유통 시설의 확충을 위한 사회간접자본의 구축을 서둘러 시행하여야 할 것이다.으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군

  • PDF

Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System (일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.176-181
    • /
    • 2011
  • The fan and pad evaporative cooling system is one of the main cooling methods in greenhouses. Its efficiency is very high, but it has some disadvantages as temperature gradient in greenhouse is large. This study was conducted to reduce the internal temperature gradients in the fan and pad cooling greenhouses. Experiments on cooling performance were carried out in a greenhouse equipped with air duct and integrated fan and pad system as an idea of this study. It showed that the cooling efficiency of an integrated fan and pad system was 75.7% in the first stage and 88.6% in the second stage. When this cooling system was operated for an unshaded and a shaded greenhouse, there were cooling effects of $5.7\sim7.6^{\circ}C$ and $7.4\sim9.7^{\circ}C$ to the control greenhouse, respectively. Maximum temperature differences in a cooling greenhouse, with a length of 18m, were $1.6\sim1.7^{\circ}C$ for shaded conditions and $2.3\sim2.7^{\circ}C$ for unshaded conditions. This greenhouse cooling method, with air duct and integrated fan and pad system, can reduce about 40~50% of the internal temperature gradients in the usual fan and pad cooling greenhouses.

An Analysis on Punching Shear of Two-way Void Slab (이방향 중공슬래브-기둥 접합부 뚫림전단성능의 해석적 평가)

  • Lee, Yung Eun;Ryu, Jaeho;Ju, Young Kyu;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.32-32
    • /
    • 2011
  • 최근 국내외에서 친환경건축물에 관한 관심이 매우 높아짐으로 인해 콘크리트의 물량을 절감하여 이산화탄소량을 줄이는 중공슬래브는 다양한 형태로 세계적으로 개발이 되고 있는 추세이다. 특히 이방향 중공슬래브는 환경적인 측면에서 이방향 중공슬래브는 중공부 생성에 재생플라스틱을 활용하여 폐자원을 재사용하고, 콘크리트와 철근의 사용량 절감에 따른 화석에너지 및 이산화탄소 발생량을 감소한다는 장점이 있다. 또한 시스템 측면에서 이방향 중공슬래브는 기존의 철근콘크리트 플랫플레이트 바닥구조 시스템의 자중을 절감하여 구조체를 경량화 시키고, 이에 따라 장스팬 구현이 가능하며, 단열효과가 뛰어나다. 이와 같이 이방향 중공슬래브는 장점이 많지만 플랫플레이트 슬래브의 취약점인 뚫림전단 파괴에 주의해야 한다. 이에 본 연구에서는 선행으로 실시된 이방향 중공슬래브-기둥 접합부 뚫림전단 성능평가 실험을 바탕으로 하여 경량체가 이방향 중공슬래브-기둥 접합부 뚫림전단 성능에 미치는 영향을 살펴보기 위해 범용 유한요소해석 프로그램인 ABAQUS를 사용하여 경량체량 및 위치를 주요변수로 한 해석적인 변화를 검토하였다. 본 연구를 통해 경량체가 삽입된 이방향 중공슬래브의 뚫림전단 성능에 대해, 해석결과 경량체 량과 위치에 따라 최대 뚫림전단강도는 기준 실험체에 비해 74.3%, 73%의 강도저하를 나타내는 것으로 알 수 있었다. 이는 실험상의 강도저하 값인 84.1%, 56.4%와 다소 차이가 있으며, 해석에서 중공부 주위의 응력집중 현상이 제대로 반영되지 않은 것으로 판단된다. 또한 이방향 슬래브에 경량체를 삽입 할 경우 경량체가 시작하는 부분에서 응력이 급격히 감소하는 현상이 나타났으며, 이러한 급격한 응력감소는 기둥 주위 위험단면의 변화를 가져오는 것으로 추정된다. 즉, 위험단면의 변화는 기둥으로부터 경량체 사이의 거리에 따라 달라지며, 위험단면 내의 콘크리트 단면 손실은 뚫림전단 강도를 감소시킨다. 본 연구에서는 이방향 중공슬래브의 뚫림전단강도를 산정할 수 있는 근사식을 제안하였으며, 보다 정확한 이방향 중공슬래브의 뚫림전단강도의 산정식을 위해서는 위험단면의 변화와 콘크리트 단면손실로 인한 전단강도 저하의 관계에 대한 추가적인 연구가 필요하다.

  • PDF