간이단열온도로서 콘크리트의 단열온도 추정을 위한 연구 (Prediction of Adiabatic Temperature in Concrete as Semiadiabatic Temperature)

  • 문한영;문대중
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.121-129
    • /
    • 2001
  • The semi-adiabatic temperature rise and the losses of temperature of cement paste, mortar and concrete were measured by an apparatus of semi-adiabatic temperature. Heat of hydration was measured by a conduction calorimeter and adiabatic temperature rise of concrete was measured by an adiabatic calorimeter. The derived equation which can assume the adiabatic temperature was proposed by measuring the semi-adiabatic temperature of concrete. The maximum adiabatic temperature rise of concrete obtained by the derived equation of adiabatic temperature, $T_{ad}(t)=T_{sad}(t)+T_{dis}(t)$, showed $55^{\circ}C$ approximately and it had good relation with the other one obtained by the heat of hydration of cement paste and with maximum value which was measured by the adiabatic calorimeter. The adiabatic temperature rise obtained by derived equation was a different information in comparison with the value obtained by adiabatic temperature rise equations by Hell and et. al. in early age, but it showed similar tendencies with the other one according to elapsed time. Adiabatic temperature rise of lich mix concrete with highly cement content was predicted. The adiabatic temperature rise of cement paste and mortar obtained by derived equation from us showed comparatively matching results to compared with that of obtained by adiabatic temperature equation from concrete standard specification.

  • PDF

전자빔 가열로 발생시킨 Gd 원자증기의 속도에 관한 연구 (Study on the velocity of gadolinium atomic vapor produced by electron beam heating)

  • 정의창;권덕희;고광훈;김택수
    • 한국진공학회지
    • /
    • 제12권4호
    • /
    • pp.228-234
    • /
    • 2003
  • 전자빔으로 증발시킨 gadolinium(Gd) 원자증기의 속도를 미량 저울(microbalance)을 사용하여 측정하였다. 증발 표면의 온도가 2400-2500 K인 조건에서 약 900 ㎧의 속도가 측정되었다. 이 값은 단열팽창을 하는 이상적 단원자의 최대 속도에 비해 약 100 ㎧ 더 빠른 속도에 해당된다. 이 특이 현상의 원인을 고온에서 여러 개의 들뜬 에너지 준위에 분포한 Gd 원자의 내부 에너지가 단열팽창 중에 운동 에너지로 전환되는 것으로 설명하였다. 100개의 들뜬 에너지 준위를 원자증기의 엔탈피에 포함시켜 속도를 계산한 값이 실험 결과와 비교적 일치함을 보였다. 가열된 표면 온도의 변화에 따른 원자증기의 유동 특성에 대해서도 보고한다.

섬유질 단열재의 열적 특성 및 내화성능 (Thermal Property and Fire Resistance of Cellulose Insulation)

  • 권영철;서성연;김성용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.203-212
    • /
    • 2005
  • 섬유질 단열재는 주로 폐신문지로 만드는 데, 내화성능을 위해 내화재로 처리된다. 내화재로 인해 연소가 되지 않을 뿐 아니라, 연기도 나지 않는다. 섬유질 단열재의 열저항은 유리섬유나 암면보다 더 뛰어나다. 섬유질 단열재는 폐지로 만들어지므로 폐기시에는 잘 부식되고, 내재에너지 또한 매우 작은 친환경 단열재이다. 국내 건축물에 섬유질 단열재를 광범위하게 이용하기 위해서는 국내 건축법규 상의 단열규정에 적합한지 여부를 판단할 수 있는 물리적 성능 테스트가 필요하다. 따라서 국내에서 생산되는 섬유질 단열재에 대한 열전도율 및 내화성능 실험을 ASTM C 518과 ASTM C 1485에 근거하여 실시하였다. 국내생산 섬유질 단열재는 동일밀도의 미국제품에 비해 열전도율이 약 5%정도 높게 나타났다. 이러한 결과는 폐지원지의 섬유질이 서로 다른데서 기인하는 것으로 판단된다. 습식분사방식과 공기충진방식 모두 온도가 $5.5^{\circ}C$ 상승할 때 마다 약 1.5%씩 열전도율이 높아지는 것으로 나타났다. 섬유질 단열재의 내화성능은 내화재의 함유량에 비례하여 일정하게 증가되는 것으로 나타났다. 높은 내화성능으로 인해 불에 약한 우레탄폼이나 스치로폼을 대체할 수 있다. 섬유질 단열재의 열전도율은 시편의 온도가 $4-43^{\circ}C$인 경우 $0.037-0.043W/m{\cdot}K$로 나타났다. 이는 국내 건축법규 상의 "나"등급에 해당하는 값이다. 내화재가 열전도율에 미치는 영향은 미미하였으며, 내화재가 전혀 들어있지 않은 경우가 가장 열전도율이 높게 나타났다. 섬유질 단열재의 단열성능은 유리섬유나 암면에 비해 뛰어나고, 스치로폼이나 우레탄폼에 비해 내화성능은 훨씬 뛰어나다. 따리서, 물리적인 성능을 고려한다면 위의 기존 단열재들을 대체할 수 있다. 섬유질 단열재는 스치로폼이나 우레탄폼에 비해 값도 싸므로 국내에서도 더욱 폭 넓게 사용하는 것이 추천된다.

콘크리트 단열온도 상승 예측에 관한 연구 (Estimation of Adiabatic Temperature Rise of Concrete)

  • 방기성;정원섭;송영철;조철희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.934-939
    • /
    • 1998
  • This study discusses the results of adiabatic temperature rise tests which were performed considering various parameters, such as cement type, water-cement ratio, unit cement weigh, admixtures and placing temperature, which influence the temperature rise(K) and reaction velocity ($\alpha$). Theadiabatic temperature rise models obtained from this study are similar to those of Japan Concrete Institute. The models to calculate temperature rise and reaction velocity could be used the analysis f concrete thermal stress.

  • PDF

Mock-up 부재에 적용한 단열 갱폼의 콘크리트 강도 특성 (Concrete Strength Characteristic of the Insulating Gang Form for Mock-Up Members)

  • 김지훈;남경용;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2013
  • In this paper, the compressive strength of an insulating gang form member, which was developed to improve the cold weather concreting quality, and a general gang form member was measured by age to examine the compressive strength characteristics of the two members compared with the standard curing test piece.

  • PDF

평관형 및 나선 그루브형 열사이폰 내부 작동유체의 포화온도와 단열부의 표면온도에 관한 연구 (A Comparison between the Internal Saturation Temperature of Working Fluid and the Surface Temperature of Adiabatic Zone of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현;박종운;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1243-1249
    • /
    • 2004
  • This study is focused on the comparison between the internal saturation temperature of the working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves. Distilled water, methanol and ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The results show that the numbers of grooves and the type of working fluids are very important factors for the operation of thermosyphons. A good agreement between the internal saturation temperature of working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves is obtained.

  • PDF

안정온도구배가 밀폐용기내의 자연대류에 미치는 영향 (Effect of Stabilizing Thermal Gradients on Natural Convection in a Completely Confined Rectangular Enclosure)

  • 김무현;이진호;장은구
    • 대한기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.1330-1338
    • /
    • 1989
  • 본 연구에서는 직각밀폐용기의 수평경계면이 단열인 경우뿐만 아니라 등온 조건을 갖는 경우에 대해 실험적으로 연구하여 경계조건의 변화가 직각밀폐용기내 흐름 및 열전달에 미치는 영향, 특히 등온조건을 갖는 경우 수직 온도차에 따르는 안정온도 구배효과로 예상되는 흐름의 억제, 지연효과를 작종 물리적 변수들의 영향과 함께 세밀히 조사하였다.

콘크리트의 수화도 및 단열온도상승량 예측모델 개발 (Mathematical Modeling of Degree of Hydration and Adiabatic Temperature Rise)

  • 차수원
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.118-125
    • /
    • 2002
  • 콘크리트는 수화과정을 통하여 재료가 성숙되고, 경화된다. 수화의 진행은 엄밀한 의미에서 재령에 의하지 않고 수화도에 의해 제어되므로, 경화가 진행되는 콘크리트의 모든 재료특성과 미세구조 형성과정은 수화도에 의해 정식화되는 것이 바람직하다. 기존 연구는 주로 양생온도가 수화발열속도에 미치는 영향을 고려한 반응함수 개념을 주로 사용하였고, 또한 내부 수분상태의 영향을 습도함수의 형태로 고려한 연구결과는 실제 수화기구를 반영하지 못하고 단지 각 연구자의 실험조건과 배합조건에만 부합하는 결과를 보인다. 따라서 본 연구는 기존 제안식의 단점을 보완하기 위하여 수화기구와 미세구조 형성 과정에 기초하여 반응속도함수를 모델링하였다. 수화반응속도는 온도 및 수분상태에 따라 변화하므로, 본 연구에서는 수화발열 속도에 영향을 미치는 인자로, 시멘트 종류, 물-시멘트비 등의 배합특성과 양생온도 빛 세공조직의 내부수분상태를 고려하였다. 똔 연구에서 제시한 콘크리트의 수화도 예측모델은 기존의 온도영향만을 주로 고려하는 반응속도함수를 콘크리트내부의 수분분포 상태를 고려하여 모델을 개선하였으며, 이는 실제 측정한 수화도에 매우 근접하여 그 유용성을 검증하였다. 또한 수화도의 정의와 제시한 모델을 이용하여 콘크리트 요소내의 온도, 습도 덴 수화도를 수치적으로 결정하여 단열온도상승곡선을 정확히 모사 할 수 있었다. 제안된 모델은 수화가 진행되는 콘크리트의 여러 역학적 특성 및 미세구조 형성과정을 적절히 표현하고, 수화과정이 온도 및 습도상태를 결정하는 초기재령 콘크리트의 단면 내 온 습도상태를 추정하여 궁극적으로 초기재령 콘크리트의 균열 위험성을 평가하는데 유용하게 이용될 수 있을 것으로 사료된다.

LNG 저장탱크 바닥판 단열 시스템 개선 (Improvement of Insulation System for LNG Storage Tank Base Slab)

  • 이용진;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.141-147
    • /
    • 2010
  • LNG 천연가스로서 저장과 운반이 용이한 액체로 변형이 가능하며, 청정연료로 각광받게 되어, 석유에너지의 의존도를 낮추고 에너지사용의 다변화를 위해 1986년 인도네시아로부터 처음 도입된 이래로 산업의 성장과 더불어 그 수요량이 지속적으로 증가하고 있다. LNG는 천연가스의 부피를 영하 약 $-162^{\circ}C(-260^{\circ}F)$까지 냉각시켜 1/600까지 줄일 수 있으므로, 저장 및 운반에 있어서 매우 효율적이다. 현대의 LNG 저장탱크는 철근 콘크리트 이중벽과 내부 니켈방호벽 및 벽사이의 효율이 높은 단열재로 구성된 완전 방호식이 적용되고 있다. 단열재는 극저온의 온도가 LNG 탱크 외벽으로 전달되는 것을 차단하며, 바닥슬래브, 외벽 및 상부에 설치된다. LNG 저장탱크의 단열재의 배치에 따라 콘크리트 외조에 작용하는 온도분포에 차이가 나므로, 본 연구에서는 기 건설된 완전 방호식 LNG 저장탱크 바닥판 단열재의 배치에 대해 검토하고, 이를 바탕으로 단열시스템 개선 방안을 제안하고자 한다.

결합재 종류에 따른 콘크리트의 단열온도상승특성 및 단열온도상승에 따른 압축강도특성에 관한 연구 (Properties of Adiabatic Temperature Rise of Concrete Using Different Types of Binder and Effects of Adiabatic Temperature on the Compressive Strength)

  • 하재담;김태홍;이종열;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.527-532
    • /
    • 2001
  • The crack of concrete induced by a temperature rise in early age concrete due to the heat of ration of cement is a serious problem for massive or high strength concrete structures. However, re is still no reasonable equations for the prediction of the temperature rising. On this study, the prediction equations of the heat of hydration of different types of binder are pained from the adiabatic temperature rise test, and compared with the results from different nations to obtain the best approximated equation. The strengths of concrete of which specimens were placed in the same chamber for the adiabatic to were compared with those under standard curing.

  • PDF