• 제목/요약/키워드: 단열보강

검색결과 30건 처리시간 0.019초

공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구 ((A)Study on Apartment Insulation Status and Insulation reinforcement Application)

  • 정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

파형 GFRP 전단연결재의 폭 및 너비에 따른 중단열 벽체의 면내전단거동 (Effects of Corrugated GFRP Shear Connector Width and Pitch on In-plane Shear Behavior of Insulated Concrete Sandwich Wall Panels (CSWP))

  • 장석준;오태식;유영찬;김호룡;윤현도
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.421-428
    • /
    • 2014
  • 이 연구는 파형 GFRP 전단연결재가 보강된 중단열 벽체의 면내전단거동을 알아보기 위하여 실시되었다. 기존의 중단열 벽체의 단열성능 향상과 내/외측 벽체의 합성거동을 위하여 파형 GFRP 전단연결재를 보강하였다. 실험체는 2개의 단열재로 구분된 3개의 콘크리트 벽체로 구성되어 있으며, 중앙부 벽체에 수직방향의 전단력을 가하였다. 주요변수는 단열재의 종류 (압출법 보온판 및 비드법 보온판) 및 보강된 전단연결재의 너비(300 및 400 mm)과 폭(10 및 15 mm)를 변수로 설정하였으며, 실험체의 파괴양상 및 전단흐름강도-평균상대변위 관계 대한 분석을 실시하였다. 실험 결과 콘크리트와 단열재의 부착응력은 중단열 벽체의 초기거동에 상당한 영향이 있는 것으로 판단되며, 전단연결재가 보강되지 않은 경우 XPSS를 사용한 중단열 벽체의 강성 및 강성이 EPS 단열재의 경우보다 높게 나타났다. 전단연결재의 보강효과는 단열재에 따라 상이하게 나타났으며, 전단연결재의 보강상세에 단열재의 역학적 특성을 고려해야 할 것으로 판단된다.

복합 단열 매트 보강 폴리우레탄 폼의 열적 성능 및 내충격성 평가 (Thermal Performance and Impact Resistance Evaluations of Composite Insulation Mat Reinforced Polyurethane Foam)

  • 황병관;배진호;이제명
    • Composites Research
    • /
    • 제32권5호
    • /
    • pp.290-295
    • /
    • 2019
  • 본 연구에서는 액화 천연 가스 운반선 단열 시스템에 적용되는 폴리우레탄 폼(Polyurethane foam, PUF)의 열적 성능 및 내충격성을 향상시키기 위한 목적으로, PUF에 복합 단열 매트를 보강하였다. 복합 단열 매트는 극저온 환경에서 운용이 가능한 케블라, 에어로겔, 그리고 크라이오겔 매트를 선정하였다. 열적 성능은 $20^{\circ}C$의 상온에서 열전도율을 측정하였으며, 내충격성은 $20^{\circ}C$의 상온 및 $-163^{\circ}C$의 극저온에서 30 J의 충격에너지로 낙하 충격 시험을 수행하여 측정하였다. 측정된 열전도율은 유효 열전도율 이론 값을 통해 보강되지 않은 PUF와 비교하였으며, 내충격성은 접촉력, 접촉 시간, 그리고 흡수에너지를 평가하였다. 실험 결과 크라이오겔 복합 매트 보강 시 가장 우수한 열적 성능을 나타났으며, 내충격성은 에어로겔 복합 매트 보강 시 가장 우수하게 나타났다.

사양 - 겨울철 육계 사양관리 점검하기

  • 유재석
    • 월간 닭고기
    • /
    • 제15권12호
    • /
    • pp.84-91
    • /
    • 2009
  • 우리나라는 사계절이 있어 여름과 겨울은 계사의 단열 수준에 따라 환기량과 습도 공급의 균형을 어떻게 유지해 주느냐가 가장 큰 사양관리의 주요한 점이다. 특히 겨울철은 개방계사라도 온도유지를 위해서 계사를 완전히 밀폐된 상태에서 사육을 하기 때문에 형식은 모든 농장이 무창계사와 동일한 상태에서 관리가 이루어진다. 그런데 무창계사의 형태이긴 하지만 단열수준이 충분히 확보되지 않는 농장이 많기 때문에 여러 가지 문제점이 발생한다. 가장 문제되는 것은 호흡기 질병에 노출되는 것인데 이에 대한 대책도 함께 점검해보자. 계사단열보강 문제, 충분한 환기를 위한 열원확보와 홴 설비, 그리고 인원적으로 공급해야 하는 습도관리, 바닥 깔짚온도, 일령에 따라 적절하게 늘려주는 문제, 환기방법, 겨울철 육추관리, 마지막으로 호흡기 질병에 대한 대책도 알아보고자 한다.

  • PDF

동계 아파트 외표면 온도에 의한 단열성능 비교평가 (Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation)

  • 박정훈;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.91-100
    • /
    • 2013
  • 이 연구에서는 기존아파트 외벽체의 단열 성능저하 및 보수보강에 필요한 기초 자료를 만들기 위해서 아파트의 구조체 단열성능 측정분석과 함께 단열하자에 대한 기준수립 및 평가를 하고자 한다. 또한 아파트 건축물 구조체의 열교 및 결로발생 부분을 예측하고자 하였다. 한편 시공연도별 분석에 의하여 단열기준 및 시간 경과에 따른 단열성능 정도를 분석하기 위함이다.

가연성 단열재를 사용한 외단열 도시형 생활주택의 방화를 위한 보강재 검토 (Examined of reinforcement for the fire protection of the outside insulation Urbantype Housing with flammable insulation material)

  • 이광희;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2015
  • Due to the big fire in Uijeongbu, the status of construction, fireproof materials and structural method were examined to prevent fire propagation through outside insulation parts of urban living homes. Through research and experiments, the following results were obtained. It was confirmed that outside heat-insulation wall method was used in a large number of urban living homes which were made of materials and structures spreading fire easily.Through experiments, it was revealed that lightweight plate material, as a fireproof material, can save the cost as well as the period of construction and obtain more than 30 minutes of evacuation time which is twice the maximum evacuation time.

  • PDF

지하 유류저장 공동의 지질구조와 공동누수량 상호관계에 관한 사례 (A Case Study of Correlation between Inflows and Geological Structures around Underground Caverns)

  • 전한석
    • 지질공학
    • /
    • 제10권1호
    • /
    • pp.79-93
    • /
    • 2000
  • 일반적으로 공동 주변에 분포하고 있는 지질구조는 지하 암반 공동 굴착시 지수, 보강, 지하수 유동 등에 상당한 영향을 주게 되므로 지질구조의 분포 및 특성을 아는 것이 매우 중요하다. 본 연구에서는 거제 지역에 기 시행된 지하 비축시설의 조사, 설계 및 시공자료를 토대로 지질구조와 공동 누수량 상호 관계를 분석한 결과, 본역에 발달하고 있는 주 함수구조대의 방향은 N50∼60W, 경사는 거의 수직이며 인장 단열로서 추정된다. 이 구조대는 양수 시험시 타원형의 장축 방향과 일치하고 N10∼30E 방향의 단열들과 교차하고 있으며, 화강섬록암에서 나타나는 전형적인 장방형 단열계를 나타낸다.

  • PDF

유리섬유복합체를 사용한 전단연결재 형상에 따른 중단열 벽체의 면내전단내력 (Effect of Glass Fiber-Reinforced Polymer (GFRP) Shear Connector's Shape on Inplane Shear Strength of Insulated Concrete Sandwich Panels)

  • 장석준;유영찬;김호룡;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.9-17
    • /
    • 2013
  • 최근, 중단열 벽체의 단열성능 향상을 위해 철과 콘크리트 코어 전단연결재를 열전도율이 낮은 유리섬유복합체 (GFRP)로 전단연결재를 대체하는 연구가 활발히 진행되고 있다. 본 연구는 단열재의 표면처리에 따른 부착력과, GFRP 전단연결재로 보강된 중단열 벽체의 전단내력을 알아보기 위하여 실시되었으며, 각 변수에 따른 영향을 분석함으로써 구조성능에 대한 검증을 실시하였다. 총 13개의 실험체에 대해 직접전단실험을 실시하였으며, 파괴양상 및 하중-상대슬립 관계에 대한 분석을 실시하였다. 실험결과, 기존의 압출법 보온판 (XPS) 단열재에 거친표면처리와 10 mm의 홈을 낸 경우 단열재와 콘크리트사이에 부착력을 향상시킬 수 있으며, 부착력의 기여는 전단연결재의 파단 상대슬립의 영향을 받는 것으로 나타났다. 파형 전단연결재의 폭이 커짐에 따라 강성이 증가하였으며, 보강단면적이 증가함에 따라 최대내력이 증가하였다. 효과적인 보강을 위해서는 파형 전단연결재의 높이와 피치의 비율을 1:2로 산정해야 할 것으로 판단되며, 안정적인 파괴를 위해서는 매립깊이에 대한 검증이 필요할 것으로 사료된다.

콘크리트에 표면매립보강된 FRP의 내화단열방법에 따른 부착성능 (Bond Capacity of Near-Surface-Mounted FRP in Concrete Corresponding to Fire-Protection Method)

  • 임종욱;김태완;서수연
    • 대한건축학회논문집:구조계
    • /
    • 제35권1호
    • /
    • pp.3-10
    • /
    • 2019
  • The purpose of this paper is to find the fire-protection method for keeping on the bond capacity of Near-Surface-Mounted (NSM) FRP under high temperature. Experiments have been carried out to evaluate the bond capacity of NSM FRP by using CFRP-plates and to confirm the heat transfer to the concrete block when the refractory insulation is attached to the surface of NSM FRP. Bond test of NSM FRP under room temperature was conducted to obtain the maximum bond strength. And then a heating tests were carried out with keeping the bond stress of 30% of the maximum bond strength. As a result, the bond capacity of NSM FRP was disappeared when the temperature at epoxy reached to its glass transition temperature (GTT). In order to secure the bond capacity of the NSM FRP, it is necessary to protect the front as well as side by using insulation materials.

콘크리트내에 표면매입 보강된 FRP의 내화성능 향상을 위한 내화단열재 열저항성능 평가 (Evaluation on the Thermal Resistance Capacity of Fire Proof Materials for Improving Fire Resistance of Near-Surface-Mounted FRP in Concrete)

  • 연제영;서수연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.51-58
    • /
    • 2014
  • 본 연구에서는 철근콘크리트 구조의 FRP를 이용한 보강에서 낮은 내화성능을 개선하기 위한 방안을 찾기 위하여, 보강된 FRP의 외부를 내화보강하는 방법에 대한 내화실험을 실시하였다. 특히 철근콘크리트 부재의 피복에 홈을 형성하여 FRP를 매입하는 보강 즉, NSM 보강을 대상으로 하였다. 실험에서의 주요 변수는 보강방법과 사용 내화재료로서, Perlite계 재료를 표면에 분사하여 보강하는 방법, Calcium silicate계 보드로 표면에 부착하는 방법, 그리고 추가로 홈내부에 Polymer mortar 또는 Calcium silicate조각을 삽입하여 보강하는 방법으로 보강한 뒤 가열로 내부의 온도변화에 따른 열전달을 관찰하였다. 실험결과, Perlite계 내화뿜칠로 표면을 보강하는 경우보다 Calcium Silicate계 내화보드로 표면을 보강하는 방법이 효과적인 것으로 나타났다. 홈 내부의 에폭시가 유리전이온도에 도달할 때의 외부 표면온도 $820^{\circ}C$까지 내화단열성능을 확보할 수 있는 것으로 나타났다.