• Title/Summary/Keyword: 단순 방사선

Search Result 495, Processing Time 0.029 seconds

Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses (X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발)

  • Byung-Ju Ahn;Yong-Wan Kim;In-Soo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.327-333
    • /
    • 2023
  • In Order to Diagnose Maxillary Bone and Maxillary Sinus in the X-Ray Paranasal Sinus Projection test, this Study used Skull Rando Phantom to Change the Posture and X-ray tube Angle to 5° of the Head or 5° of ROC Who worked for more than 10 years. The Significance of the Evaluated score was Verified through SPSS Ver. 3.0, and the Cronbach value was Significantly higher at 0.712. In addition, as a Result of Calculating SNR by Setting the ROI(Receiver Operation Characteristic) of the Maxillary bone and Maxillary sinus images, it was the Highest at 6,449 in the Examination by tilting 5° toward the Head or Leg of the X-ray tube. In the study, it is believed that among the X-Ray simple Paranasal Sinus projection tests, a sharp Image can be Obtained during the Examination by Tilting the X-ray tube 5° toward the Head or Leg.

Survey of the Musculoskeletal Disorders of Riot Police and Conscripted Policeman in Radiologic Examination (전.의경의 방사선 검사를 통한 근골격계 질환 현황 조사)

  • Cho, Jae-Hwan;Kang, Maeng-Jin;Seok, Jong-Min;Jeun, Sung-Joon;Lim, Youn-Shik;Jeong, Jae-Kyo;Kim, Hyeon-Ju;Ju, Myeong-Shik;Dong, Kyung-Rae;Park, Cheol-Soo;Lee, Jin;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.315-324
    • /
    • 2011
  • The purpose of this study was to use as basic data for the is systematic and efficient facility inventory of policeman and the riot police, conscripted policeman. First, the analysis was performed for the patient implementing the simple x-ray, CT, and MRI examination to the policeman and the riot police, conscripted policeman within the radiologic examination. As to the classification by disease, it classified into the partial body as the common disease and musculoskeletal system disease. As to the fixed quantity comparison of the policeman and the riot police, conscripted policeman the basic X-ray, CT, MRI examination by part average personnel was compared. As to the research result the riot police, conscripted policeman, the Lower extremity examination occupies the simple X-ray, CT, and MRI examination in comparison with the other part altogether much and particularly, the Knee examination ratio occupies much among the Lower extremity examination.

A study on the radiation exposure of simple abdomen Radiation in Radiography (복부 단순 방사선 검사 시 피폭선량에 대한 연구)

  • Yeo, Jin-Dong;Kim, Mi-Sook
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.5-10
    • /
    • 2007
  • This study was performed to measure about exposure dose during simple abdmon radiation radiography. The exposure dose was measured by PDD, surface dose, respectively. The result was as followed: 1. When tube voltage were increased with 60-85kv, surface dose were increased. When FFD(focus film distance) at the 50-150cm and mAs were increased, surface dose were decreased. 2. The percentage depth dose(PDD) were appeared 50% below depth dose at 4cm with 60-75kv, and 6cm depth with 80-85kv, 5% below depth dose at 12cm with 60kv, and depth with 65-85kv. 3. The percentage forward scatter increased from 10% to 11.78% at the 60-85kv. The back scatter dose were increase from 25% to 37% at the 60-85kv. The side scatter dose were affected to heel effect.

  • PDF

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Is it Possible to predict the Characteristics of Calcific Deposition in Calcific Tendinitis of Shoulder Joint? (단순 방사선 검사를 이용하여 석회성 건염에서 발생하는 석회 침착물의 성상에 대한 예측이 가능한가?)

  • Kim, Sung-Jae;Lee, Hee Jae;Lee, Kwang-Hyun;Park, Dong-Hyeok;Lee, Bong Geun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.77-83
    • /
    • 2014
  • Purpose: The purpose of current study was to evaluate the validity of the existing radiological classifications as a diagnostic modality for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint. For that purpose, we determined the inter-observer reliability for evaluating diagnostic precisions of the classification and also evaluated diagnostic accuracy of predicting the toothpaste type calcific deposition. Materials and Methods: We performed retrospective study with total 26 patients surgically treated with calcific tendinitis of the shoulder joint from March 2010 to October 2013. Two independent observers reviewed preoperative radiographs of shoulder joints, and classified the characteristics of calcific depositions according to the criteria of Gartner, DePalma and Patte. Cohen's kappa were calculated for each classifications to evaluate inter-observer reliability. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were determined for type of calcific depositions with Gartner type III, DePalma type I, and Patte type II for predicting toothpaste type calcific deposition. Results: The values of Cohen's kappa were the highest in the classification of Patte, 0.62, and the values for the classifications of DePalma and Gartner were 0.56 and 0.36, respectively. The sensitivities for predicting toothpaste type calcific deposition in Gartner Type III, DePalma type I and Patte type II were 83.3%, 91.7%, and 58.3%, respectively. Specificities were 85.7% 50.0% and 64%, positive likelihood ratios were 5.833, 1.833 and 1.633, negative likelihood ratios were 0.194, 0.167 and 0.648, and diagnostic odds ratios were 30.00, 11.00 and 2.52, respectively. Conclusion: There were no radiologic classifications of calcific tendinitis which has both high precision and accuracy. Further studies with other diagnostic modalities such as ultrasonography are needed for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint.

  • PDF

Radiographers: Responsible Medical Professional or Detached Employee? (방사선사: 전문 의료직인가? 단순 기술직인가?)

  • Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.234-240
    • /
    • 2008
  • This article examines the professional status of radiographers in an attempt to answer the question "Radiographers: responsible medical professional or detached employee?" Comparisons are made on the past and present views of radiography with thoughts given into the possible change for the future. It can be clearly seen that the professional rights have been taken away as a result of overwhelming medical dominance but changes are slowly taking to place which are attempting to replace the lost autonomy to place radiography as a profession once again.

Interpretation of Plain Chest Radiography - Focused on Findings of Normal and Pneumonia- (소아 단순 흉부 X-선 사진의 판독 - 정상 및 폐렴 소견을 중심으로 -)

  • Lee, Hee Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1311-1316
    • /
    • 2002
  • 단순 흉부 X-선 사진은 흉곽내에 공기를 함유하고 있는 폐실질, 심장과 대혈관을 포함한 연부조직, 그리고 흉곽을 이루는 골격 등의 다양한 조직으로 이루어진 3차원적인 해부학적 구조물을 X-선 film이라는 2차원적 평면에 흑백의 음영으로 표현하는 검사이다. 뿐만아니라 이들 구조물들이 전후, 좌우로 겹쳐져 있어 병변이 쉽게 가려질 수 있고, 폐실질 질환 뿐만 아니라 심장 질환 또한 폐실질의 변화를 유발시킬 수 있으므로, 단순히 각 질환의 X-선 소견에 대한 지식을 습득하는 것보다는 병인과 해부학적인 지식에 대한 이해를 기본으로 X-선 판독에 임하는 것이 중요하다. 또한 환자들의 임상 증상과 부합되지 않는 X-선 소견이 관찰되거나, 치료 도중 임상 경과와 판독소견이 일치되지 않는다면 방사선과 전문의와의 긴밀한 의견교환이 진단과 치료에 중요하리라 생각된다.

A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen (복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구)

  • Kim, Sung-Soo;Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

A Study on the Phenomena of Renal Stone in Simple Radiography (X선 단순촬영에 있어서 신장결석의 출현에 관한 검토)

  • Yoo, Jang-Soo;Song, Jae-Kwan;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 1989
  • This paper investigated on influence on the distinguishability of renal stone in the accordance with thickness of object, x-ray tube voltage and base density. In the relationship between object and renal stone shadow, object and tube voltage, the obtained results can be summarized as the following. 1. When thickness of object was thin, the distinguishability increased in base density $2.0{\sim}2.5$, but for adults was best shown in base density 1.5. 2. In the relationship between object and tube voltage, the distinguishability increased at lower tube voltages ($50{\sim}60\;kVp$), using grid. As mentioned above, it was thought that this method was very effective in describing the phenomena of renal stone in film density 1.5, tube voltages 60 kVp.

  • PDF

A Study of the Medical Exposure Dose in Abdomen A-P X-ray Examination (복부(腹部) 단순X선검사시(單純X線檢査時) 피검자(被檢者)의 피폭선량(被曝線量)에 대(對)한 연구(硏究))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 1994
  • This study was conducted to find out the medical exposure dose in simple abdomen A-P projection of adults, based on the 87 hospitals located in Seoul. As the results, the following conclusions have been reached; 1. 88.5 % of the surveyed hospitals had the use of $65\;kVp{\sim}79\;kVp(M{\pm}SD:71.45{\pm}4.73\;kVp)$ as tube voltage. 2. 87.35 % of the surveyed hospitals had the use of $50\;mAs{\sim}89\;mAs(M{\pm}SD:64.31{\pm}16.21\;mAs)$ as the amount of current. 3. Shallow doses ranged from 2.00 mSv to 4.99 mSv($M{\pm}SD:3.81{\pm}1.01\;mSv$) in 80.46 % of the surveyed hospitals. 4. Exposure dose was directly depended on the tube voltage or the amount of currents.

  • PDF