• Title/Summary/Keyword: 단면적 배분

Search Result 7, Processing Time 0.027 seconds

An aspect of Gagok enjoyment in the early 19th century (19세기 초반, 가곡 향유의 한 단면 - 『영언』과『청륙』의 ‘이삭대엽 우ㆍ계면 배분방식’을 대상으로 -)

  • 성무경
    • Sijohaknonchong
    • /
    • v.19 no.1
    • /
    • pp.235-260
    • /
    • 2003
  • Recently, I presented Gagok(歌曲) Collection Yeong-eon永言 to learned circles. Yeong-eon is very similar to Yukdang-version六堂本 CheongGuYeongeon靑丘永言. Compared with Cheong- Yuk, it is the same age or little bit early time of Cheong-Yuk in culture Icon. This paper paid attention to the considerable difference between Yeong-eon and Cheong-Yuk in the way of the distribution of Yisakdaeyap二數大 葉's Woo mode羽調 and Ke-myeon mode界面調. There was the way of gathering ‘real name’+‘namelessness’ in Yisakdaeyap, which is the feature of the 18th century Gagok Collection. I found this way just put on the 19th century Gagok Collection way which is the distribution of Yisakdaeyap's 'Woo mode and Ke-myeon mode' in CheongYuk. Then I proved in this paper that the way of gathering Yisakdaeyap in Cheong Yuk didn't correspond to an actual singing in the early 19th century when 'Woo mode and Ke-myeon mode' was fixed. In case of Yeong-eon, however, it was not written any writers' names at all, when it was researched retroactively, I knew it was distributed evenly both the works of 'real name' and 'namelessness' in Yisakdaeyaps 'Woo mode and Ke-myeon mode'. Consequently, I found Yeong-eon is the good Gagok Collection for an actual singing at that time. In addition, there was discord in the mode or key distribution among many Gagok Collections. I found this issue of the application had kept on make Gagok Collections edit during 2 centuries. Because the actual Gagok enjoyment in the specific time is connected the way of the mode application directly.

  • PDF

플로팅 건축의 출현배경과 유형구분 기준

  • Park, Seong-Sin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.206-208
    • /
    • 2011
  • 플로팅건축물은 최근 지구온난화에 따른 해수면의 상승, 소득 증대 및 관광행태 변화에 따라 급증한 해양 레포츠 수요에 대응하는 효과적인 건축물이다. 플로팅건축은 프로그램, 형태, 건축규모, 층수, 위치, 접근방법, 이동성, 에너지 자립도 등 8가지 기준에 따라 유형 구분이 가능하다. 또한 시공된 주거시설을 대상으로 분석한 결과 플로팅건축의 디자인 특성은 (1) 2층 규모, (2) 면적 비율이 높은 데크, (3) 장방형의 균형감 있는 매스, (4) 조망 극대화, (5) 친수공간 확보, (6) 공간의 통합적 사용 및 합리적 면적 배분의 평면계획, (7) 수면 반사를 고려한 단면계획, (8) 모듈화 및 유닛화 등으로 정리할 수 있다.

  • PDF

A Study on Flow Distribution in a Clean Room with Multiple Exits (다수의 출구를 가지는 크린룸 내부의 기류분포에 관한 연구)

  • Lee, Jae-Heon;Lee, Sie-Un;Kim, Sukhyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.418-425
    • /
    • 1988
  • Since conventional computer program is workable only with velocity boundary condition, in practical fluid passage such as clean room which usually have wide inlets and outlets, it is not easy to measure velocity itself because of its vector property. Furthermore a certain assumption of velocity at boundaries may lead to physically unreasonable results. From this motivation, we have developed a computer program to predict whole flow field imposed on pressure-based boundary condition which can be measured by relatively simple method. The only additional velocity boundary condition that should be imposed on to make the problem unique, are no slip condition at all walls and zero cross stream velocity at inlet. The result of present study was compared with that by Bernoulli equation being used practically. They were coincident well each other within 5%, therefore the validity of the present method is proved. In the present work, the flow field in a clean room subject to pressure-based boundary conditions at an inlet and two exits was predicted numerically. The pressure difference between the inlet and the left exit which keeps relatively low pressure among two exits is fixed as 150[Pa] and the pressure at the right exit is varied from zero to 150[Pa] by the increment of 25[Pa]. For each cases the flow characteristics in the clean room, the velocity profile at the inlet, and the flow rate through the two exits was predicted. The flow rate through the right exit imposed on relatively higher pressure than the left exit decreased linearly according to the increase of pressure of the right exit. When the pressure of the right exit is increased enough to cause back flow at the exit, the flow rate is rapidly decreased.

  • PDF

Simple Model for Preliminary Design of Hexagrid Tall Building Structure (헥사그리드 고층건물구조의 예비설계를 위한 단순모델)

  • Lee, Han-Ul;Kim, Young-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.13-20
    • /
    • 2017
  • High-rise building shapes are changing from orthogonal to irregular form and the current trend is to arrange members in geometric grid-patterns at the perimeter of buildings. This study proposes a simple model for the preliminary design of a hexagrid high-rise building. The size of the cross section is set to be different at each module and hexagrid unit, which is different from the previous studies in which all hexagrid members were the same. To examine the effect of hexagrid size on structural performance, 60-story hexagrid buildings with 1-, 2- and 4-story high modules are designed and analyzed. Maximum lateral displacement, steel tonnage, load carrying percentage of perimeter frame and combined strength ratio are compared for 15 buildings. As the lateral load carrying capacity of hexagrid structure was inferior to a diagrid structural system, proper lateral stiffness should be allocated to the core frame in a hexagrid structure. The best ratio of flexural to shear deformation was 4 and larger unit size was better in considering constructional cost and structural efficiency. As the maximum lateral displacements of the buildings were within 84%~108% of the limit, the proposed method seems to be applicable to preliminary design of hexagrid buildings.

A Study on Architectural Type and Design Characteristics of Floating Architecture (플로팅건축의 유형 및 디자인 특성에 관한 연구)

  • Pak, Sung-Sine
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.407-414
    • /
    • 2011
  • Floating architecture is the most effective way to accommodate itself to sea-level rise due to climate change. At the same time floating architecture is the best model to offer the new spatial experience through water-friendly environment. Domestic floating architecture is still on the early stage compared to Europe which has several companies specialized in designing and building floating architecture. Floating architecture is divided into 8 types according to its criteria such as program, form, scale, level, location, access, mobility and energy. The following are design characteristics of floating architecture : (1) composed of 2 stories, (2) having large deck, (3) designing rectangular plan and balanced mass, (4) maximizing view, (5) having water-friendly space, (6) multi-using space and minimizing surface, (7) planning section to control light reflecting from the water, (8) modular and unit system.

Analysis of Reinforcement Effect of Hollow Modular Concrete Block on Sand by Laboratory Model Tests (실내모형실험을 통한 모래지반에서의 중공블록 보강효과 분석)

  • Lee, Chul-Hee;Shin, Eun-Chul;Yang, Tae-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.49-62
    • /
    • 2022
  • The hollow modular concrete block reinforced foundation method is one of the ground reinforcement foundation methods that uses hexagonal honeycomb-shaped concrete blocks with mixed crushed rock to reinforce soft grounds. It then forms an artificial layered ground that increases bearing capacity and reduces settlement. The hollow modular honeycomb-shaped concrete block is a geometrically economical, stable structure that distributes forces in a balanced way. However, the behavioral characteristics of hollow modular concrete block reinforced foundations are not yet fully understood. In this study, a bearing capacity test is performed to analyze the reinforcement effectiveness of the hollow modular concrete block through the laboratory model tests. From the load-settlement curve, punching shear failure occurs under the unfilled sand condition (A-1-N). However, the filled sand condition (A-1-F) shows a linear curve without yielding, confirming the reinforcement effect is three times higher than that of unreinforced ground. The bearing capacity equation is proposed for the parts that have contact pressure under concrete, vertical stress of hollow blocks, and the inner skin friction force from horizontal stress by confining effect based on the schematic diagram of confining effect inside a hollow modular concrete block. As a result of calculating the bearing capacity, the percentage of load distribution for contact force on the area of concrete is about 65%, vertical force on the area of hollow is 16.5% and inner skin friction force of area of the inner wall is about 18.5%. When the surcharge load is applied to the concrete part, the vertical stress occurs on the area of the hollow part by confining effect first. Then, in the filled sand in the hollow where the horizontal direction is constrained, the inner skin friction force occurs by the horizontal stress on the inner wall of the hollow modular concrete block. The inner skin friction force suppresses the punching of the concrete part and reduces contact pressure.

The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching (산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도)

  • Kim, You-Lee;Kim, Jee-Hwan;Shim, June-Sung;Kim, Kwang-Mahn;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.148-156
    • /
    • 2008
  • Statement of problems: Self-etch adhesives exhibit some clinical benefits such as ease of manipulation and reduced technique-sensitivity. Nevertheless, some concern remains regarding the bonding effectiveness of self-etch adhesives to enamel, in particular when so-called 'mild' self-etch adhesives are employed. This study compared the microtensile bond strengths to ground enamel of the two-step self-etch adhesive Clearfil SE Bond (Kuraray) to the three-step etch-and- rinse adhesive Scotchbond Multi-Purpose (3M ESPE) and the one-step self-etch adhesive iBond (Heraeus Kulzer). Purpose: The purpose of this study was to determine the effect of a preceding phosphoric acid conditioning step on the bonding effectiveness of a two-step self-etch adhesive to ground enamel. Material and methods: The two-step self-etch adhesive Clearfil SE Bond non-etch group, Clearfil SE Bond etch group with prior 35% phosphoric acid etching, and the one-step self-etch adhesive iBond group were used as experimental groups. The three-step etch-and-rinse adhesive Scotchbond Multi-Purpose was used as a control group. The facial surfaces of bovine incisors were divided in four equal parts cruciformly, and randomly distributed into each group. The facial surface of each incisor was ground with 800-grit silicon carbide paper. Each adhesive group was applied according to the manufacturer's instructions to ground enamel, after which the surface was built up using Light-Core (Bisco). After storage in distilled water at $37^{\circ}C$ for 1 week, the restored teeth were sectioned into enamel beams approximately 0.8*0.8mm in cross section using a low speed precision diamond saw (TOPMET Metsaw-LS). After storage in distilled water at $37^{\circ}C$ for 1 month, 3 months, microtensile bond strength evaluations were performed using microspecimens. The microtensile bond strength (MPa) was derived by dividing the imposed force (N) at time of fracture by the bond area ($mm^2$). The mode of failure at the interface was determined with a microscope (Microscope-B nocular, Nikon). The data of microtensile bond strength were statistically analyzed using a one-way ANOVA, followed by Least Significant Difference Post Hoc Test at a significance level of 5%. Results: The mean microtensile bond strength after 1 month of storage showed no statistically significant difference between all adhesive groups (P>0.05). After 3 months of storage, adhesion to ground enamel of iBond was not significantly different from Clearfil SE Bond etch (P>>0.05), while Clearfil SE Bond non-etch and Scotchbond Multi-Purpose demonstrated significantly lower bond strengths (P<0.05), with no significant differences between the two adhesives. Conclusion: In this study the microtensile bond strength to ground enamel of two-step self-etch adhesive Clearfil SE Bond was not significantly different from three-step etch-and-rinse adhesive Scotchbond Multi-Purpose, and prior etching with 35% phosphoric acid significantly increased the bonding effectiveness of Clearfil SE Bond to enamel at 3 months.