• Title/Summary/Keyword: 다호흡

Search Result 110, Processing Time 0.023 seconds

Current Analysis of Acintobacter baumannii Infection among Pediatric Patients in a Single-centered Study (단일기관 내 소아에서 Acinetobacter baumannii 의 감염현황의 분석)

  • Park, Hye Jin;Kim, Jung Min;Kim, Ki Hwan;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • Purpose : Acinetobacter baumannii is an aerobic, gram negative coccobacillus. Due to its pathogenicity and ability to accumulate diverse mechanisms of resistance, the importance of this organism is increasing. Many reports have targeted adults, and studies of pediatric patients are limited. This study aims to investigate the current status of A. baumannii infection in children. Methods : From January 2001 to December 2008, 505 patients hospitalized with A. baumannii infection were enrolled. Admission records for underlying disease, duration of hospitalization, previous antibiotic use, location of admission, presence of ventilator care, and resistance to antibiotics were retrospectively reviewed and analyzed. Results : Hemato-oncological disease and neurological disease were 30.6% and 24.3% of all cases; therefore, these were the most common underlying diseases of patients with A. baumannii infection. Prevalence of A. baumannii infection was 78.1% in patients with previous antibiotic use, which was higher than that of the group not using previous antibiotic. And prevalence of multi-drug resistant and pan-drug resistant A. baumannii infection was 76.4% and 38.3% in patients with ICU care, 76.8% and 38.9% with ventilator care, and these were higher than the others. Rate of resistance to all groups of antibiotics showed a gradual increase to over 50% in 2008. Multi-drug resistant A. baumannii was 63.5% and pan-drug resistant A. baumannii was 48.2% of all cases. Conclusion : Prevalence of A. baumannii infection and resistance to antibacterial agents of A. baumannii is increasing. Adequate use of antibiotics and infection control should be emphasized in pediatric patients.

업체탐방 - (주)바이오엔그린텍

  • Kim, Dong-Jin
    • KOREAN POULTRY JOURNAL
    • /
    • v.47 no.2
    • /
    • pp.103-107
    • /
    • 2015
  • 국내 축산업은 구제역, AI 등 법정전염병 발생은 물론 각종 호흡기성 및 세균성 질병이 끊임없이 발생해 농가피해가 심하고 식품의 안전성을 위협받고 있다. 또 다자간 FTA 체결로 값싼 외국산 축산물 수입량이 증가함에 따라 내 우외환의 홍역을 앓고 있는 실정이다. 축산업이 국내외적으로 어려운 시기에 경쟁력을 강화하기 위해서는 생산성 향상을 통한 생산비 절감과 함께 사육환경을 개선해 안전한 식품을 공급하는 동물복지형 친환경축산이 그 대안으로 평가 받고 있다. 이러한 시대적 요청을 선도하기 위해 동물복지형 친환경축산 발전에 기여하는 천연물 및 유익 미생물을 통해 질병, 환경 및 사료를 효과적으로 관리하여 농가소득 증대를 꾀하고, 나아가 축산 경쟁력 제고에 기여할 수 있는 친환경 제품의 개발에 박차를 기하는 업체를 방문하였다.

Analysis of Immergence using Multi-Channel Biological Signals and Neural Network in Virtual Reality Environment (다 채널 생체신호와 신경회로망을 이용한 가상환경 하에서의 임장감 분석)

  • 박민재;박광석;김현택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.236-241
    • /
    • 2000
  • 가상환경 하에서의 임장감을 객관적으로 계측하기 위한 방법으로 생체신호를 이용한 감성의 계측을 시도하였다. 여러 가지 가상환경 하에서 뇌파, 심전도, 호흡 등 다 채널의 생체신호를 계측하고 이때 피실험자가 느끼는 객관화된 임장감 지표들을 동시에 평가하여 이를 신경 회로망을 이용하여 분석하였다. 계측된 생체 신호를 사전 처리하여 일차적인 생체분석 지표들을 도출하고 이를 신경회로망의 입력으로 활용하였다. 임장감을 분석할 수 있도록 신경회로망을 학습시키고, 이를 이용하여서 가상환경 하에서 계측된 생체신호를 분석하여 임장감을 정량화하여 평가하였다.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Successful Management of Feline Infectious Peritonitis with Human Recombinant Interferon-alpha and Pentoxifylline in a Cat (재조합 인간 인터페론 알파와 Pentoxifylline을 이용한 고양이 전염성 복막염의 치료 증례)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.427-430
    • /
    • 2011
  • A 6-month-old intact female, domestic short hair cat was presented with dyspnea and anorexia for 2 days. Physical examination revealed muffled heart sound with labored breaths. Hyperproteinemia and hyperglobulinemia with polyclonal gammapathy was revealed. Pleural effusion was non-septic exudates, it also had hyperglobulinemia with decreased albumin: globuline ration. In addition, effusion RT-PCR for feline coronavirus was positive in this cat. Feline infectious peritonitis (FIP) was strongly suspected and aggressive treatments with human interferon-alpha, pentoxifylline, and glucocorticoids were initiated. The cat remained healthy without recurrence of pleural effusion during 5 months follow-up periods. To the author's knowledge, this is the first case report describing successful management of FIP with human interferon-alpha and pentoxifylline in Korea.

Seasonal Variation of Contribution of Leaf-Litter Decomposition Rate in Soil Respiration in Temperate Deciduous Forest (토양호흡의 계절적 변이에 기여하는 리터의 분해속도)

  • Suh Sang-Uk;Min Youn-Kyung;Lee Jae-Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.57-65
    • /
    • 2005
  • In a forest ecosystem, the major source of soil carbon input is from litterfall and its decomposition. To understand the effect of litterfall and litter decomposition on seasonal variation of soil respiration and litter decomposition rates were measured in temperate deciduous forest in Korea. Annual litterfall collected from litter trap (1m x 1m) were 147.5 ± 8.2g Cm/sup -2/ yr/sup -1/ in 2003. About 47% of litterfall were Quercus serrata leaf followed by Carpinus laxiflora leaf (27 %), Carpinus cordata leaf (7 %), and others, such as other leaf, bark, branch, and acorn, were 20%. The decomposition rate was the highest in C. cordata (33.03%, k = 0.46), followed by C. laxiflora (25.73%, k = 0.30), and Q. serrata (24.17%, k = 0.28). The continuous measurement of soil respiration from January 2004 to December 2004 was carried out using AOCC (Automatic Open-Closed multi-Chamber system). The annual soil respiration rate was 629.6g Cm/sup -2/ yr/sup -1/ and the litter decomposition was 30.0g Cm/sup -2/ yr/sup -1/. The portion of litter decomposition rate on soil respiration rate was about 5%. From January to February, when the soil respiration rate was the lowest, about 11 % of soil respiration (7.4 ± l.4g Cm/sup -2/ month/sup -1/) were effected by litter decomposition rate (0.8g Cm/sup -2/ month/sup -1/). The highest soil respiration rate (111.5 ± 16.2g Cm/sup -2/ month/sup -1/) and litter decomposition rate (11.4g Cm/sup -2/ month/sup -1/) were showed in July to August. According to the regression analysis between soil respiration rate and litter decomposition, the soil respiration rate were related to litter decomposition with the correlations (r = 0.63).

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

Pulmonary Artery Aneurysm in Behcet's Disease (베체트 질환에 발생한 폐동맥류 -치험 1예-)

  • 박승일;원준호;이종국
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.660-664
    • /
    • 1999
  • Behcet's disease is classically described as featuring recurrent aphthous ulcers in the mouth and genital organs and as having relapsing iritis. Now it is being recognized as a mul tisystem disorder that involves of the skin, gastrointestinal system, cardiovascular system, lung and the central nervous system as well as the joints, blood vessels and urologic systems. Large vessel diseases are unusual but aneurysm may occur in which the pulmonary circulation may give rise to the massive and often fatal hemoptysis. A 29 year-old man who complained of having dyspnea and hemoptysis during six months visited our hospital. He received right bilobectomy for a mass located in the right lower lobe. He underwent right bilobectomy. The final pathologic diagnosis was a pulmonary artery aneurysm which origina ted from the pulmonary artery.

  • PDF

The Effect of Nasal BiPAP Ventilation in Acute Exacerbation of Chronic Obstructive Airway Disease (만성 기도폐쇄환자에서 급성 호흡 부전시 BiPAP 환기법의 치료 효과)

  • Cho, Young-Bok;Kim, Ki-Beom;Lee, Hak-Jun;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.190-200
    • /
    • 1996
  • Background : Mechanical ventilation constitutes the last therapeutic method for acute respiratory failure when oxygen therapy and medical treatment fail to improve the respiratory status of the patient. This invasive ventilation, classically administered by endotracheal intubation or by tracheostomy, is associated with significant mortality and morbidity. Consequently, any less invasive method able to avoid the use of endotracheal ventilation would appear to be useful in high risk patient. Over recent years, the efficacy of nasal mask ventilation has been demonstrated in the treatment of chronic restrictive respiratory failure, particularly in patients with neuromuscular diseases. More recently, this method has been successfully used in the treatment of acute respiratory failure due to parenchymal disease. Method : We assessed the efficacy of Bilevel positive airway pressure(BiPAP) in the treatment of acute exacerbation of chronic obstructive pulmonary disease(COPD). This study prospectively evaluated the clinical effectiveness of a treatment schedule with positive pressure ventilation via nasal mask(Respironics BiPAP device) in 22 patients with acute exacerbations of COPD. Eleven patients with acute exacerbations of COPD were treated with nasal pressure support ventilation delivered via a nasal ventilatory support system plus standard treatment for 3 consecutive days. An additional 11 control patients were treated only with standard treatment. The standard treatment consisted of medical and oxygen therapy. The nasal BiPAP was delivered by a pressure support ventilator in spontaneous timed mode and at an inspiratory positive airway pressure $6-8cmH_2O$ and an expiratory positive airway pressure $3-4cmH_2O$. Patients were evaluated with physical examination(respiratory rate), modified Borg scale and arterial blood gas before and after the acute therapeutic intervention. Results : Pretreatment and after 3 days of treatment, mean $PaO_2$ was 56.3mmHg and 79.1mmHg (p<0.05) in BiPAP group and 56.9mmHg and 70.2mmHg (p<0.05) in conventional treatment (CT) group and $PaCO_2$ was 63.9mmHg and 56.9mmHg (p<0.05) in BiPAP group and 53mmHg and 52.8mmHg in CT group respectively. pH was 7.36 and 7.41 (p<0.05) in BiPAP group and 7.37 and 7.38 in cr group respectively. Pretreatment and after treatment, mean respiratory rate was 28 and 23 beats/min in BiPAP group and 25 and 20 beats/min in CT group respectively. Borg scale was 7.6 and 4.7 in BiPAP group and 6.4 and 3.8 in CT group respectively. There were significant differences between the two groups in changes of mean $PaO_2$, $PaCO_2$ and pH respectively. Conclusion: We conclude that short-term nasal pressure-support ventilation delivered via nasal BiPAP in the treatment of acute exacerbation of COPD, is an efficient mode of assisted ventilation for improving blood gas values and dyspnea sensation and may reduce the need for endotracheal intubation with mechanical ventilation.

  • PDF

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF