• Title/Summary/Keyword: 다중 챔버

Search Result 43, Processing Time 0.029 seconds

Structural Safety Evaluation of Multi-Pressure Integrated Chamber for Sport-Multi-Artificial Environment System (스포츠 멀티 인공환경 시스템을 위한 다중압력 일체형 챔버의 구조안전성 평가)

  • Lee, Joon-Ho;Kang, Sang-Mo;Chae, Jae-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.324-328
    • /
    • 2019
  • There are several dedicated individual chambers for sports that are supplied and used, but none of them are multi-pressured all-in-one chambers that can provide a sport-multi environment simultaneously. In this study, we design a multi-pressure (positive / atmospheric / negative pressure) integrated chamber that can be used for the sport-multi-artificial environment system. We presented new chamber designs with enlarged space for the tall users and then carried out structural analysis with maximum stress and structural safety. Under the targeted allowable pressure conditions, maximum stresses occurred at the joint of the shell and the entrance, the structural safety of the chamber was evaluated with the allowable stress of its material. As a result of the structural analysis of the multi-pressure integrated chamber, the maximum stress for the positive pressure and negative pressure conditions was much smaller than the allowable stress of its material. And as a result of the structural safety evaluation, it was confirmed that the design of the final prototype for the chamber was structurally safe by satisfying the safety factor of 2 or more.

Performance Evaluation of MIMO System by Spatial Correlation in Reverberation Chamber (잔향챔버내에서 공간 상관도에 의한 MIMO 시스템의 성능평가)

  • Kim, Jong-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.26-33
    • /
    • 2014
  • The spatial correlation (SC) for a multipath environment based on a $2{\times}2$ MIMO system are computed on the observation planes in the Rayleigh/Rician fading channels inside a mode stirred chamber. The correlation coefficients were obtained and compared for different distances and orthogonal polarization between two transmit antennas. The proposed method is useful for quantifying the potential diversity gain in antenna diversity systems.

정전구동 방식의 연동형 마이크로펌프의 제작

  • Hong, Pyo-Hwan;Jeong, Dong-Geon;Gong, Dae-Yeong;Pyo, Dae-Seung;Lee, Jong-Hyeon;Lee, Dong-In;Jo, Chan-Seop;Kim, Bong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.448-448
    • /
    • 2013
  • 최근 생물학적 분석 기구에서 시료를 처리, 분리, 검출, 샘플링 또는 분석하기 위해 사용되는 마이크로펌프(Micropump)에 대한 관심이 높아지고 있다. 또한 전자소자의 성능과 신뢰성의 증진을 위한 전자소자의 열 문제를 해결하기 위해 냉각장치로 마이크로 펌프가 적용되기도 한다. 그 외에도 마이크로펌프는 다양한 분야에 응용이 가능하다. 마이크로펌프는 작동 방식에 따라 압전형, 공압형, 열공압형, 연동형 등의 여러 종류로 분류되고 있다. 그중에서도 최근에는 연동형 마이크로 펌프의 개발이 각광받고 있다. 기존의 연동형 펌프들은 다중 챔버를 가지고 있으며, 각각의 챔버 내에서 Dead volume이 많이 발생할 뿐만 아니라 이상적인 연동운동과는 차이가 많이 나는 문제점을 가지고 있다. 또한 압전방식과 열공압방식은 느린 응답성으로 인해 효율적인 유체 이동이 어렵다. 본 논문에서는 이상적인 연동운동을 구현하기 위하여 기존의 연동형 펌프의 단점을 보완하고, 하나의 챔버에 다중전극 구조를 가지는 정전기력방식의 연동형 펌프를 개발하였다. 정전기력방식으로 펌프를 구동함으로써, 저전력으로 펌프구동이 가능하며, 하나의 챔버에 다중전극을 설치함으로써 이상적인 연동운동을 재현하였다. 그리고 Dead volume을 최소화 하였다. 또한, 빠른 반응속도로 인해 효율적인 유체 이동을 실현시킬 수 있었다. 본 연구에서 제안된 마이크로 펌프의 구성은 크게 챔버, 박막, Inlet/outlet hole으로 구성되었다. 챔버는 Si-wafer에 wet etching 공정으로 제작 하였고 그 위에 알루미늄 박막을 200 nm 증착시켰다. 챔버는 가로 32 mm, 세로 5 mm, 깊이는 $15{\mu}m$, 부피는 $200{\mu}l$으로 제작되었다. 박막은 폴리이미드(polyimide)를 사용하여 $3{\mu}m$의 두께로 제작 되었으며, 폴리이미드 박막 사이에는 200 nm 두께의 4개의 알루미늄 박막 전극을 삽입시켰다. 삽입된 4개의 전극에 개별적인 전기신호를 보냄으로써 연동운동이 가능하다. Inlet/outlet hole은 직경 2 mm의 크기로 제작되었으며, 튜브를 연결하여 유체가 흐를 수 있는 체널을 형성하였다. 제작된 마이크로 펌프의 구동전압은 115 V이며, 인가되는 주파수를 1 Hz~100 KHz까지 변화시켜 유량을 측정하였다. 작동 유체는 공기이며, 유량측정은 튜브 내에 물방울을 삽입하여 시간에 따른 이동거리를 관측하였다. 측정결과 2.2 KHz에서 2.4 mm/min의 가장 높은 유량을 확인할 수 있었다. 본 연구를 통해 제안된 연동형 마이크로펌프는 이상적인 연동운동이 가능함으로써 기존의 연동형 방식의 문제점을 보완하였으며, 생명과학, 의학, 화학 등의 분야에서 적용이 가능하리라 기대된다.

  • PDF

Local Behaviour of Propagating Flames in an Explosion Chamber (폭발챔버에서 전파하는 화염의 국부 거동)

  • Park, Dal-Jae;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.32-35
    • /
    • 2011
  • Experimental studies were carried out in an explosion chamber to investigate the influences of multiple cylinder obstacles on local flame propagation. The chamber dimension is 235 mm in height with a $1,000{\times}950\;mm^2$ rectangular cross section and a large vent area of $1,000{\times}320\;mm^2$. Multiple cylinder bars with obstruction ratio of 30% were used. In order to examine the interaction between the propagating flames and the obstacles, temporally resolved flame front images were recorded by a high speed video camera. The propagation behaviour of local flame fronts around the left obstacle was analyzed in terms of two different methods such as the incremental burnt area divided by the flame front length and the average of the local propagation velocity determined at each point along the flame front. It was found that two methods give good consistency.

A Multi-chambered Single Autoinjector: Design and Performance Assesment (다중챔버 단일주사기: 설계, 성능 평가)

  • An, Seoyeon;Lee, Keunwoo;Kwon, Taekeun;Kim, Dongyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.170-180
    • /
    • 2017
  • An autoinjector allows a single use medical device serving for automatic intramuscular injection to deliver a dose of a particular emergency drug through an intuitive activation mechanism. By design and structure, autoinjectors are easy to use and are intended for self-administration by patients or untrained personnel. Depending on the number of drugs filled in the cartridge, autoinjectors are divided by one-chamber type and multi-chamber type. Most autoinjectors may have a special structure including spring-loading syringes and needle which is specially designed to ensure strength due to the necessity of penetration through layers of clothing. The purpose of this study was to introduce the design technology of autoinjector of multi-chamber type that could be released into the two drugs sequentially. Additionally, we verified performance of the prototype developed by applying the design.

Implementation of Multi-Beam Pattern Compact MIMO Antenna based on Switched Parasitic Antenna (SPA 기반 다중 빔 패턴 고집적 안테나 개발)

  • Yoon, Sang-Ok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.219-224
    • /
    • 2020
  • In this paper, we studied the compact MIMO(: Multi-Input Multi-Output) antenna for multi-beam pattern generation and control in narrow space. The characteristics and performance of the basic Dipole SPA and Monopole SPA structures are shown. We implemented a monopole SPA antenna and measured its performance in an 802.11g system. When the average transmission rate was measured using the SPA antenna, the SPA antenna improved the best performance by 8.7 times compared to commercial antenna.

A Study on the Multiple OWC Chamber Motion in Waves (다중 OWC챔버 구조물의 운동해석)

  • Hong, Do-Chun;Hong, Sa-Young;Hong, Seok-Won
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.202-205
    • /
    • 2002
  • The motion of a floating body with multiple owe chambers in waves is studied taking account of fluctuating air pressure in the chambers. The atmospheric pressure drop in one chamber is interrelated with the drop in the other chamber. Velocity potential in the water due to the free surface oscillating pressure patches is calculated by making use of the hybrid Green integral equation. The chamber motion in the frequency domain is calculated for various values of parameters related to the atmospheric pressure drop in the multiple chambers.

  • PDF

The Continuous Measurement of CO2 Efflux from the Forest Soil Surface by Multi-Channel Automated Chamber Systems (다중채널 자동챔버시스템에 의한 삼림토양의 이산화탄소 유출량의 연속측정)

  • Joo, Seung Jin;Yim, Myeong Hui;Ju, Jae-Won;Won, Ho-yeon;Jin, Seon Deok
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.1
    • /
    • pp.32-43
    • /
    • 2021
  • Multichannel automated chamber systems (MCACs) were developed for the continuous monitoring of soil CO2 efflux in forest ecosystems. The MCACs mainly consisted of four modules: eight soil chambers with lids that automatically open and close, an infrared CO2 analyzer equipped with eight multichannel gas samplers, an electronic controller with time-relay circuits, and a programmable logic datalogger. To examine the stability and reliability of the developed MCACs in the field during all seasons with a high temporal resolution, as well as the effects of temperature and soil water content on soil CO2 efflux rates, we continuously measured the soil CO2 efflux rates and micrometeorological factors at the Nam-san experimental site in a Quercus mongolica forest floor using the MCACs from January to December 2010. The diurnal and seasonal variations in soil CO2 efflux rates markedly followed the patterns of changes in temperature factors. During the entire experimental period, the soil CO2 efflux rates were strongly correlated with the temperature at a soil depth of 5 cm (r2 = 0.92) but were weakly correlated with the soil water content (r2 = 0.27). The annual sensitivity of soil CO2 efflux to temperature (Q10) in this forest ranged from 2.23 to 3.0, which was in agreement with other studies on temperate deciduous forests. The annual mean soil CO2 efflux measured by the MCACs was approximately 11.1 g CO2 m-2 day-1. These results indicate that the MCACs can be used for the continuous long-term measurements of soil CO2 efflux in the field and for simultaneously determining the impacts of micrometeorological factors.

28 GHz 초전도 ECRIS의 마이크로파 전파 특성 및 이를 이용한 시스템 설계

  • Wang, Seon-Jeong;Won, Mi-Suk;Lee, Byeong-Seop;An, Chan-Yong;Kim, Seon-Ho;Gwak, Jong-Gu;Jeong, Seung-Ho;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.134-134
    • /
    • 2010
  • KBSI 부산센터에 건설중인 소형의 다중 양전하 중이온 가속기에 사용될 초전도 ECR 이온온은 최대 자기장 3 T, 최소 0.5 T의 자기 Mirror구조를 가지고 있으며 중심 부근의 1 T 자기장에서 28 GHz 전자공명에 의해 마이크로파의 에너지를 플라즈마로 전달한다. 최대 10 kW의 Gyrotron에서 TE02 모드로 발생하는 마이크로파는 모드변환기, 직류차단기 및 진공창을 통하여 플라즈마로 입사된다. 32.5 mm 지름의 원형 도파관에서 자기장 축방향으로 도입된 TE01 모드의 마이크로파를 Altar-Appleton-Hartree 분산관계식을 이용하여 군속도의 관점에서 살펴보았다. 플라즈마 밀도가 Cut-off에 근접하지 않는 한 마이크로파의 바깥 방향으로의 회절은 크지 않았으며, 전자공명 위치로 접근함에 따라 군속도의 방향이 바뀌어 오히려 중심 방향으로 향함을 알 수 있다. 즉 마이크로파가 플라즈마 챔버의 벽을 가열시킬 가능성은 크지 않은 것이다. 또한 뜨거운 전자 플라즈마의 Susceptibility를 이용하여 마이크로파의 플라즈마로의 전자 공명에 의한 흡수를 살펴본 결과, 운전 영역에 속하는 전자밀도가 제공되면 공명 지점에 이르기 전에 충분히 흡수되는 것을 확인하였으며, 이에 따라 챔버를 관통하여 인출부 벽에 충돌하는 마이크로파 에너지는 무시할 수 있을 것으로 보여진다. 이 결과들을 토대로 마이크로파 시스템을 설계 완료하였다.

  • PDF