• Title/Summary/Keyword: 다단식옹벽

Search Result 7, Processing Time 0.021 seconds

Design Aspects of Soil-Reinforced Segmental Retaining Walls in Tiered Arrangement - Case Study (다단식 보강토 옹벽의 설계 - 사례연구)

  • Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.1 no.1
    • /
    • pp.31-41
    • /
    • 2002
  • This paper presents the results of stability analyses on soil-reinforced segmental retaining walls in a tiered arrangement. Four different walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was also performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

  • PDF

Geosynthetic-Reinforced Segmental Retaining Walls in Tiered Arrangement - Case Study and Field Trial Wall Instrumentation (다단식 보강토 옹벽의 설계 - 사례연구 및 시험시공)

  • Yoo, Chung-Sik;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 2004
  • This paper presents the results of stability analyses on soil-reinforced segmental retaining walls in a tiered arrangement. Four different walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was also performed based on the method recommended by FHWA design guidelines. Also presented are the results of instrumentation on a full-scale field trial wall constructed as part of this study. The implications of the findings from this study are discussed.

  • PDF

A Study on the Behavior of Multi-tiered Reinforced Earth Retaining Wall (다단식 보강토 옹벽의 거동특성 연구)

  • 유한규;한석준;박언상
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.3
    • /
    • pp.83-94
    • /
    • 2001
  • 본 연구에서는 상.하단으로 구분된 2개의 동일한 보강토옹벽에 대해서 상호 이격거리에 따른 수치해석을 수행하여 전면벽체의 수평변위, 전면벽체 배면의 수평토압, 보강토체 배면의 수평토압 그리고 보강재의 최대인장력 분포 및 크기변화 양상 등 다단식 보강토옹벽의 거동을 살펴보았다. 또한, 하단 옹벽에 증가되는 응력을 산정하고자 중첩의 원리를 적용한 2:1 응력분포법을 제시하였다. 수치해석 결과 이격거리가 증가함에 따라 상단옹벽이 하단옹벽에 미치는 영향이 감소하였으며 하단 옹벽 높이의 두배 이상 이격시, 상호 거동은 독립옹벽으로 거동하였다. 하단 옹벽내 응력 산정방법에 있어서 NCMA의 방법이 가장 보수적인 결과를 보였으며 본 연구에서 제시한 2:1 응력분포법중 주동파괴면을 고려하지 않은 방법이 수치해석 결과와 가장 유사하게 나타났다.

  • PDF

Numerical Analysis for Optimum Reinforcement Length Ratio of Reinforced Earth Retaining Wall (보강토옹벽의 최적 보강길이비 산정을 위한 수치해석적 연구)

  • Park, Choonsik;Ahn, Woojong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.5-14
    • /
    • 2018
  • Recently, method of reinforced earth retaining wall have been proposed according to the material of facing, geosynthetic, construction method, and facing slope. However, the regulations such as the design method and detailed review items according to each construction method are not clear, and collapse due to heavy rainfall frequently occurs. In this study, to obtain a more stable technical approach in the design of reinforced earth retaining wall, the combination of the pullout failure of reinforced earth retaining wall and the optimal reinforcement ratio of height using reinforced earth retaining wall using a single strength reinforcement is assumed, optimum design of stiffener, optimal design of superimposed wall and optimum length ratio of reinforcement material of geosynthetics are proposed through safety factor according to reinforcement length ratio (L/H).

Design Case Study of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration (다단식 보강토 옹벽의 설계 사례 연구)

  • 유충식;허병주
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.115-125
    • /
    • 2003
  • This paper presents the results of design case study on soil-reinforced segmental retaining walls in tiered configuration. Six different field walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was additionally performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and Internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

Analysis of the Behavior of Tiered Reinforced Soil Retaining Wall Considering the Offset Distance by Surcharge Load (상재하중 이격거리에 따른 다단식 보강토옹벽의 거동특성 분석)

  • Han, Jung-Geun;Kim, Ji-Sun;Hong, Ki-Kwon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.4
    • /
    • pp.31-40
    • /
    • 2007
  • Recently, the scale in the field of reinforced soil retaining wall has been grown up like tiered reinforced soil retaining wall. However, there have been increasing number of collapse accidents and large scale of collapse. The design manual adopted in the construction fields have been inconsistent in tiered reinforced soil retaining wall. Therefore, this study performed finite element analysis on 90 cases and analyzed characteristic behavior of lower wall which was one of the effect factors on the stability of tiered reinforced soil retaining wall. The facing displacement of each walls and the behavior of the whole ground were interpreted by the numerical analysis depending on the lower offset distance by the upper wall as well as the upper offset distance by the surcharge load. The results showed that the behavior of tiered reinforced soil retaining wall was differed by condition of surcharge load and each offset distance was found to be important factor.

A Case Study on Design of Geosynthetic-Reinforced Segmental Retaining Walls (다단식 보강토 옹벽 설계사례에 관한 고찰)

  • Park, Si-Sam;Cho, Sam-Deok;Park, Du-Hee;Chang, Ki-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.168-175
    • /
    • 2008
  • The method of reinforced earth walls has grown remarkably and the frequency of utilization has been increased on a national scale thereafter introduced in the middle 1980s in Korea. Furthermore the construction case of the extensive Geosynthetic-Reinforced Segmental Retaining Walls had been increased. Currently, the design criterion of FHWA and NCMA mainly used in Korea suggest determining the horizontal distance of the upper/lower retaining wall based on the study results of the internal stability and the external stability of Segmental Retaining Walls but in many cases are not suitable for the actual situation in Korea. Therefore, in this study reviewed the design criterion of Geosynthetic-Reinforced Segmental Retaining Walls, performed the internal and external stability in Paju, Gyeonggi-do based on the design criterion of FHWA and NCMA, suggested the modified design criterion of FHWA with analyzing the results, and performed the stability analysis for the internal and external stability and the compound failure. Moreover for the confirmation of the modified FHWA design standard, the suggestion and the analysis of the numerical analysis approaching method using shear strength reduction technique were performed and the design cases utilized the modified FHWA design standard based on the study analysis were introduced.

  • PDF