• Title/Summary/Keyword: 다공판

Search Result 137, Processing Time 0.038 seconds

Effect of the through-flow on the absorption performance of a perforated plate system (다공판 시스템의 흡음성능에 관통유동이 미치는 효과)

  • 허성욱;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.163-167
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that fur the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but for the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

An Experimental Study on the Grazing Incidence Sound Absorption of a Perforated Panel System (다공판 시스템의 접선입사 흡음성능에 관한 실험적 연구)

  • Je, Hyun-Su;Yang, Soo-Young;Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1052-1055
    • /
    • 2004
  • This paper introduces an experimental study on the grazing incidence sound absorptions for duct silencers filed with a glass wool and consisted of a perforated panel. The experimental results are discussed in comparison with the normal incidence sound absorption. And also the transmission loss for duct silencers are measured and compared with the sound absorption performances. From the experimental results, it is shown that the resonance frequency bandwidth on the transmission loss and sound absorption coefficient for duct silencers has a good agreement.

  • PDF

The experimental study on the counter-current flow limit in the flow path with a porous plate (다공판 유로내의 유동한계(CCFL)에 대한 실험적 연구)

  • Lee, Jin-Ki;Yang, Seung-Woo;Kwon, Jung-Tae;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.176-181
    • /
    • 2006
  • Experiments of Counter-Current Flow Limit(CCFL or Flooding) is performed to improve the drawbacks of Wallis' Correlation which neglects the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In this study, CCFL is observed by changing shape of porous plate using air and water. Results show that as the size of porous increases, CCFL with round shape of the porous plate decreases. In the present study, a CCFL correlation is developed and the CCFL map is proposed based on the present experimental results. developed by this experimental study.

  • PDF

Improvement of Optical and Thermo-mechanical Properties of Polycarbonate-based Diffusers for LED Backlight Unit by Incorporation of Porous Silica Particles (실리카 다공체에 의한 발광다이오드 백라이트 유닛용 폴리카보네이트계 확산판의 광학 및 열-기계적 물성의 향상 연구)

  • Kim, Hyo Jin;Kim, Dong Won;Kim, Seong Woo
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.761-767
    • /
    • 2012
  • The polycarbonate (PC)-based optical diffusers for direct-lit LED backlight unit were prepared by using extrusion compounding followed by compression molding process. The application of inorganic porous silica particles as a diffusing agent in addition to conventional poly(methyl methacrylate) (PMMA) beads was attempted, and the optical, thermal, and mechanical properties of the prepared diffusers were investigated. The morphological observations revealed that the diffusing agents could be uniformly dispersed in the PC matrix without agglomeration by high shear stress generated during extrusion process. The incorporation of the porous silica particles mixed with PMMA beads remarkably enhanced the luminance uniformity with respect to both location and view angle for the diffuser, while minimizing the reduction in the absolute luminance, as compared with the diffuser containing only PMMA beads. In addition, thermal and mechanical properties of the diffusers were shown to be improved upon addition of the porous silica particles.

A Study on the Flow Characteristics of the Catalytic Combustor for the Gas Turbine (가스터빈용 촉매 연소기의 유동 특성에 관한 연구)

  • Hong, Dong-Jin;Kim, Chong-Min;Kim, Man-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.792-798
    • /
    • 2007
  • catalytic combustion is accomplished by the chemical reaction between fuel and oxidizer at the catalyst surface, different from conventional combustion. Therefore, it is important that the fuel and air stream are well mixed and supplied uniformly prior to the combustion region. If the flow is maldistributed, a hot spot may occur that can lead to subsequent catalyst and substrate damage. Therefore, in order to enhance the mixing and flow uniformity, in this study, the perforated plate is used. A numerical simulation is performed to investigate the variation of flow characteristics by changing various parameters. Under each condition, the uniformity of the flow stream at the entrance of the catalyst section is evaluated and compared. The results show that the uniformity can be effectively improved for most of the case by using the well-designed perforated plates.

A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks (제철슬러지 소각로 열교환기에서의 파울링특성 연구)

  • 박상일;김정근;김기홍;박용준;조성문
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.223-230
    • /
    • 2003
  • A study was performed to measure and analyze the gas-side fouling of heat exchanger to cool the exhaust gas from sludge incinerator at ironworks. The incinerator gas passes through inside of the vertical tubes of heat exchanger to preheat the combustion air. This kind of fouling occurs at the entrance region of the heat exchanger and thus the perforated fouling plate was designed to measure the gas-side fouling and to analyze the particulate deposit. As a result of analysis, the particulate deposition rate was influenced by temperature, particulate composition and size and also the deposition patterns were different according to the location of perforated fouling plate. The computational analysis was performed to obtain the deposition rates at the perforated fouling plate and the calculation showed that the deposition rate was varied with the hole size and particulate size. It was proved that the fouling at the entrance region of heat exchanger could be measured by the perforated fouling plate designed in this study.

Study on the Performance of Total Heat Exchanger with Rotating Porous Plates (다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅱ) - 전열판의 회전수 변환에 대하여 -)

  • Lim, T.W.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.18-23
    • /
    • 2005
  • The experimental investigation was carried out to evaluate the performance of air-to-air heat exchanger with rotating porous plates newly developed in this study. The rotating porous plates are mounted with an equal interval of 18 mm inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. The material of the porous plate is cooper and its thickness is 1.0 mm. Air flow rate is varied from 10 to 120 m3/h. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat exchange performance increased with the increase in RPM of the porous rotating discs at the conditions of the same air flow rate. The sensible heat exchange efficiency was maximum 60 to 70 percent, and enthalpy exchange efficiency 50 to 60 percent.

  • PDF