• Title/Summary/Keyword: 능동 바이어스 회로

Search Result 32, Processing Time 0.018 seconds

Highly Linear 1 W Power Amplifier MMIC for the 900 MHz Band Using InGaP/GaAs HBT (InGaP/GaAs HBT를 이용한 900 MHz 대역 1 W급 고선형 전력 증폭기 MMIC 설계)

  • Joo, So-Yeon;Han, Su-Yeon;Song, Min-Geun;Kim, Hyung-Chul;Kim, Min-Su;Noh, Sang-Youn;Yoo, Hyung-Mo;Yang, Youn-Goo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.897-903
    • /
    • 2011
  • This paper presents a highly linear power amplifier MMIC, having an output power level of about 1 watt, based on InGaP/GaAs hetero-junction bipolar transistor(HBT) technology for the 900 MHz band. The active bias circuit is applied to minimize the effect of temperature variation. Ballast resistors are optimized to prevent a current collapse and a thermal runaway. The fabricated power amplifier exhibited a gain of 17.6 dB, an output P1dB of 30 dBm, and a PAE of 44.9 % at an output P1dB from the one-tone excitation. It also showed a very high OIP3 of 47.3 dBm at an average output power of 20 dBm from the two-tone excitation.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF