• Title/Summary/Keyword: 능동필터

Search Result 512, Processing Time 0.025 seconds

Comparison of Harmonic Detecting Methods For Sing-Phase Multi Level Active Power Filters (단상 멀티레벨 능동전력필터를 위한 고조파 검지 기법 비교)

  • Kim, Yoon-Ho;Kim, Soo-Hong;Kim, Sung-Min;Seo, Kang-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.494-497
    • /
    • 2005
  • In this paper, harmonic detecting methods for the active power application are investigated. They are RDFT, Kalman Filter, Adaptive predictive filter, Instantaneous reactive power detecting method, Improved adaptive filter detecting method. The 5 harmonic detecting methods are simulated and their characteristics for the active filter application are compared using simulation results.

  • PDF

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters with LCL Filter (LCL필터를 가진 3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 전향보상기법)

  • Park, Byong-Jun;Choi, Ki-Young;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.214-215
    • /
    • 2013
  • 본 논문은 계통 연계형 인버터 제어에 있어서 계통 임피던스에 의한 계통전압 왜곡을 분석하고 있다. 특히 계통 연계형 인버터의 설계단계에서는 고려되지 않지만, 실제 시스템 구현 시에는 일반적으로 널리 사용되는 저주파트랜스의 누설 인덕턴스에 의한 영향을 살펴보았다. 계통 임피던스에 의해 계통 전압의 왜곡이 발생하고 이로 인해 저차 고조파 성분의 전류가 계통으로 유입되게 되는데, 본 논문에서는 이 저차 고조파에 대해 분석하고, 이를 감쇄시키는 기법을 소개한다. 제안하는 방법은 1.5kW 전압형 인버터의 시물레이션을 통해 검증하였다.

  • PDF

Four Switch Three-Phase Z-Source Active Power Filter (Four-Switch 3상 Z-소스 능동전력필터)

  • Qiu, Xiao-Dong;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.224-225
    • /
    • 2013
  • This paper describes the four switch three-phase Z-source active power filter. This novel configuration has many advantages like reduction of cost, switching loss and smaller drive circuit. The paper presents an application of direct current control(DCC) method in a three-phase parallel Z-source active power filter to reduce the harmonics generated by the nonlinear load. The compensation principles and dynamics of the system are discussed in detail. The results show that the proposed control strategy is feasible and efficient.

  • PDF

Isolated bidirectional DC-DC converter with high power conversion ratios (고 전력변환 비를 가지는 절연형 양방향 DC-DC 컨버터)

  • Lee, Sung-Ho;Kim, Kyu-Tae;Kwon, Jung-Min;Kwon, Bong-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.171-172
    • /
    • 2013
  • 본 논문에서는 저 전압원과 고 전압원간의 양방향 전력 변환에 적합한 절연형 양방향 DC-DC 컨버터를 제안한다. 제안하는 컨버터는 저압 측에 전류형 능동 클램프 푸쉬풀 컨버터 구조와 고압 측에 배전압 회로를 가지는 하프 브릿지 구조를 가진다. 저압 측의 전류형 컨버터의 적용은 별도의 필터 없이도 저압 측의 전류 리플의 저감 효과 시킬 수 있으며, 고 주파수 변압기의 턴 비를 낮출 수 있다. 또한 배전압 회로를 통해 전류 대비 고압 측 소자의 전압 스트레스의 저감 효과를 기대할 수 있다. 최종적으로 제안하는 컨버터의 모의 실험결과를 통해 타당성을 검증한다.

  • PDF

Active Control of Noise In HVAC Ducts Using Hybrid Adaptive Filter (하이브리드 적응 필터를 이용한 공조 덕트에서의 능동소음제어)

  • Nam, Hyun-Do;Kim, Duck-Joong;Sung, Dae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2417-2419
    • /
    • 1998
  • In this paper, a new active noise control technique which combines a hybrid active noise control technique and a subband active noise control technique is presented. To reduce the computational burden the active noise control system, a weighted hybrid control technique is applied. This algorithm shows higher stability and good noise attenuation property in either broad band or narrow band active noise control systems in HVAC ducts. Computer simulations were performed to show the effectiveness of the proposed algorithm.

  • PDF

STABLE ADAPTIVE IIR FILTERS FOR ACTIVE NOISE CONTROL (능동 소음제어를 위한 안정한 적응 IIR 필터)

  • Hong, Sun-Chul;Yang, Dong-Sung;Nam, Ill-Ryong;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3118-3120
    • /
    • 2000
  • In this paper. a stable IIR adaptive filter for active noise control is proposed. The IIR filter structure is more effective when acoustic feedback exists, in which case an order of a FIR filter must be very large if some of the poles of the ideal control filter are near the unit circle. But the IIR filter may have stability problems especially when the adaptive algorithm is not converged. A stabilizing procedure for IIR adaptive filter is presented in this paper, and computer simulation is performed to show the effectiveness of proposed schemes.

  • PDF

A New Control Strategy of The Active Power Filter (능동 전력 필터의 새로운 제어 방법)

  • Yo, Wan-Sik;Kim, Nam-Jeung;Cho, Kyu-Min;In, Chi-Gak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1174-1176
    • /
    • 2000
  • This paper presents a new control strategy of the active power filter to compensate the fundamental and high order reactive power. Using the proposed control strategy, the calculation of active and reactive power of the load is not required. So the system configurations and the controller can be constructed very simply. To decrease the load of active power filter, the LC passive filter bank can be used without any additional strategy. In this paper, the algorithm of the proposed new control strategy is discussed and the experimental results are shown.

  • PDF

A New Control Method of Series Single-Phase Hybrid Active Power Filter (직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법)

  • Kim, Jin-Sun;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF

Implementation of Active Monopole Antenna with Embedded Bandpass Filters for Antenna (대역통과 필터가 내장된 능동 모노폴 안테나 구현)

  • Jang, Jin-Woo;Lee, Won-Taek;Kim, Joon-Il;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.81-82
    • /
    • 2007
  • This paper presents a WLAN band active monopole antenna which is made of a CPW-fed monopole antenna and a low noise amplifier implemented on single-layer low-temperature co-fired ceramic (LTCC) substrate. Planar active antenna measure return loss and power test. (drain voltage = 4V, gate voltage = -0.6V). The bandwidth, is 540MHz, return loss is -38dB.

  • PDF

A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터)

  • 김윤호;김수홍;이강희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.