• Title/Summary/Keyword: 누출 위험도

Search Result 369, Processing Time 0.028 seconds

A Study on Smart Real-time Atmospheric Dispersion System (지능형 실시간 대기확산 시스템에 관한 연구)

  • Oh, Jeong-Seok;Hyun, Ji-I;Bang, Hyo-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.44-51
    • /
    • 2012
  • It is more important to realize safety management, medium-large accident prevention and risk prediction as accident of industry facilities can generate enormous physical and human damage because most energy plant might handle toxic substance. Especially, atmospheric dispersion system, which is able to simulate situation, have been used for release accident of toxic substance since the accident can show different of dispersion range and velocity according to release material, storage facility and atmospheric status. However those systems have been used generally in design step of industry facility and are difficult to deal with release accident quickly. Although some researches and cases have been studied for using real-time atmospheric information, there are insufficient system for processing quickly release accident. This paper aims to develop real-time smart atmospheric dispersion system that can deal with release accident quickly by enhancing distinct characteristics and efficiency of energy plant, and select release time and area using intelligent algorithm as accident prevention type.

Technical Review on Risk Assessment Methodology for Carbon Marine Geological Storage Systems (이산화탄소 해양 지중저장 시스템에서의 누출 위해성 평가방법에 관한 기술적 검토)

  • Hwang, Jin-Hwan;Kang, Seong-Gil;Park, Young-Gyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Carbon Capture and Storage (CCS) technology mitigates the emission amount of carbon dioxide into the atmosphere and can reduce green house effect which causes the climate change. Deep saline aquifer or obsolete oil/gas storage etc. in the marine geological structure are considered as the candidates for the storage. The injection and storage relating technology have been interested in the global society, however the adverse effect caused by leakage from the system failure. Even the safety level of the CCS is very high and there is almost no possibility to leak but, still the risk to marine ecosystem of the high concentrated carbon dioxide exposure is not verified. The present study introduces the system and environmental risk assessment methods. The feature, event and process approach can be a good starting point and we found the some possibility from the fault tree analysis for evaluation. From the FEP analysis, we drove the possible scenario which we need to concentrate on the construction and operation stages.

Pleurodesis with Autologous Blood Plus Sclerosing Agents (자가혈과 늑막유착제를 이용한 늑막유착술 -치험 2례 보고-)

  • 송종필;이종호;김병열;이정호;강경민
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.92-95
    • /
    • 1999
  • The patients with prolonged air leak after lung resection surgery were generally treated by pleurodesis with sclerosing agents such as talc, tetracyclin, doxycyclin, bleomycin, vibramycin, and OK432. However, for the case like dead space resulted by incomplete reexpansion of the remaining lung, chemical pleurodesis has shown to be not as effective as expected. If the patients keep the chest tube for long period of time, the risk of thoracic empyema would increase. Most thoracic surgeons have experienced prolonged airleak which developed after lung resection. Pleurodesis with autoblood was reported as an effective method in treatment of patients with prolonged airleak. The mechanism of blood pleurodesis may be direct obliteration of BPF and reduction of dead space by clot. Therefore we successfully treated the two patients with prolonged airleak using the autoblood plus OK432 or vibramycin.

  • PDF

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space (수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구)

  • Baek, Doo-San;Kim, Hyo-Gyu;Park, Jin-Yuk;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2021
  • Hydrogen in hydrogen-electric vehicles has a wide range of combustion and explosion ranges, and is a combustible gas with a very fast flame propagation speed, so it has the risk of leakage, diffusion, ignition, and explosion. The fuel tank has a Thermally active Pressure Relief Device (TPRD) to reduce the risk of explosion and other explosions, and in the event of an accident, hydrogen inside the tank is released outside before an explosion or fire occurs. However, if an accident occurs in a semi-closed space such as an underground parking lot, the flow of air flow is smaller than the open space, which can cause the concentration of hydrogen gas emitted from the TPRD to accumulate above the explosion limit. Therefore, in this study, the leakage rate and concentration of hydrogen over time were analyzed according to the diameter of the nozzle of the TPRD. The diameter of the nozzle was considered to be 1 mm, 2.5 mm and 5 mm, and ccording to the diameter of the nozzle, the concentration of hydrogen in the underground parking lot increases in a faster time with the diameter of the nozzle, and the maximum value is also analyzed to be larger with the diameter of the nozzle. In underground parking lots where air currents are stagnant, hydrogen concentrations above LFL (Lowe Flammability Limit) were analyzed to be distributed around the nozzle, and it was analyzed that they did not exceed UFL (Upper Flammability Limit).

A Numerical Study on the CO2 Leakage Through the Fault During Offshore Carbon Sequestration (해양지중에 저장된 이산화탄소의 단층을 통한 누출 위험 평가에 관한 수치해석 연구)

  • Kang, Kwangu;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To mitigate the greenhouse gas emission, many carbon capture and storage projects are underway all over the world. In Korea, many studies focus on the storage of $CO_2$ in the offshore sediment. Assurance of safety is one of the most important issues in the geological storage of $CO_2$. Especially, the assessment of possibility of leakage and amount of leaked $CO_2$ is very crucial to analyze the safety of marine geological storage of $CO_2$. In this study, the leakage of injected $CO_2$ through fault was numerically studied. TOUGH2-MP ECO2N was used to simulate the subsurface behavior of injected $CO_2$. The storage site was 150 m thick saline aquifer located 825 m under the continental shelf. It was assumed that $CO_2$ leak was happened through the fault located 1,000 m away from the injection well. The injected $CO_2$ could migrate through the aquifer by both pressure difference driven by injection and buoyancy force. The enough pressure differences made it possible the $CO_2$ to migrate to the bottom of the fault. The $CO_2$ could be leaked to seabed through the fault due to the buoyancy force. Prior to leakage of the injected $CO_2$, the formation water leaked to seabed. When $CO_2$ reached the seabed, leakage of formation water stopped but the same amount of sea water starts to flow into the underground as the amount of leaked $CO_2$. To analyze the effect of injection rate on the leakage behavior, the injection rate of $CO_2$ was varied as 0.5, 0.75, and $1MtCO_2/year$. The starting times of leakage at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 11.3, 15.6 and 23.2 years after the injection, respectively. The leakage of $CO_2$ to the seabed continued for a period time after the end of $CO_2$ injection. The ratios of total leaked $CO_2$ to total injected $CO_2$ at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 19.5%, 11.5% and 2.8%, respectively.

Process Risk Assessment for a Batch Condensation Reaction of Polyester Resin using K-PSR Technique (K-PSR 기법을 활용한 회분식 폴리에스터 축합반응에서의 공정 위험성 평가 연구)

  • Park, Kyung-Min;Lee, Dong-Kyu;Lee, Haakil;Lee, Joon-Man;Ahn, Won-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.35-42
    • /
    • 2019
  • Risk assessment and analysis for a medium-to-small sized chemical plant that manufactures a polyester resin by the process of batch-type condensation reaction was conducted using K-PSR technique which is one of the risk assessment methods used to implement the Process Safety Management System (PSM). K-PSR is a risk assessment technique developed by KOSHA to compensate for difficulties caused by the lack of infrastructure of medium-to-small sized chemical plants in the re-evaluation. To apply the K-PSR technique, the entire process of a selected chemical palnt was classified in two review sections, i.e., the condensation reaction process and the dilution/filtration process, and the potential risks of the process about these review sections were identified and classified based on the four guide-words (release, fire.explosion, process trouble, and injury). As the results of the research, refer to recommend of risk rating has been confirmed that non-destructive testing of old facilities and the preparation of LOTO procedures for the electrical equipments are necessary as specific measures to prevent the risk of release and fire.explosion. It was also shown that pressure gauges and thermometers should be installed on the hot-oil supply piping to minimize the process trouble, and exhausting hood should be installed to prevent potential injury.

A Study on the Quantitative Risk Assessment of Hydrogen-LPG Combined Refueling Station (수소-LPG 복합충전소 정량적 위험성평가에 관한 연구)

  • Kang, Seung Kyu
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, a quantitative risk assessment was carried out for a hydrogen complex station. The complex fueling station to be evaluated was hydrogen-LPG, and the components of each station were analyzed and the risk was evaluated. The final risk is assessed by individual and societal risks, taking into account the impact of damage and the frequency of accidents. As a result of individual risk calculation for the hydrogen-LPG fueling station that is the subject of this study, the hydrogen-LPG type fueling station does not show the unacceptable hazardous area (> 1 × 10E-3) proposed by HSE. The level of individual risk for both the public and the worker is within acceptable limits. In societal risk assessment, the model to be interpreted shows the distribution of risks in an acceptable range(ALARP, As Low As Reasonably Practicable). To ensure improved safety, we recommend regular inspections and checks for high-risk hydrogen reservoirs, dispensers, tube trailer leaks, and LPG vapor recovery lines.

A basic study on the hazard of hydrogen feul cell vehicles in road tunnels (도로터널에서 수소차 위험에 관한 기초적 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Hydrogen is a next-generation energy source, and according to the roadmap for activating the hydrogen economy, it is expected that industries to stably produce, store, and transport of hydrogen as well as the supply of hydrogen fuel cell vehicles will be made rapidly. Accordingly, safety measures for accidents of hydrogen vehicles in confined spaces such as tunnels are required. In this study, as part of a study to ensure the safety of hydrogen fuel cell vehicles in road tunnels, a basic investigation and research on the risk of fire and explosion due to gas leakage and hydrogen tank rupture among various hazards caused by hydrogen fuel cell vehicle accidents in tunnels was conducted. The following results were obtained. In the event of hydrogen fuel cell vehicle accidents, the gas release rate depends on the orifice diameter of TPRD, and when the gas is ignited, the maximum heat release rate reaches 3.22~51.36 MW (orifice diameter: 1~4 mm) depending on the orifice diameter but the duration times are short. Therefore, it was analyzed that there was little increase in risk due to fire. As the overpressure of the gas explosion was calculated by the equivalent TNT method, in the case of yield of VCE of 0.2 is applied, the safety threshold distance is analyzed to be about 35 m, and number of the equivalent fatalities are conservatively predicted to reach tens of people.

A Study on the Impact of Protection Layers on Workplace Workers in the Event of a Toxic Substance Release (독성물질 누출 시 방호계층 적용에 따른 사업장 내 근로자 피해 영향 연구)

  • Sun Jae Hwang;Joon Won Lee;Deuk Hwan Kim;Sang Chan Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.43-49
    • /
    • 2023
  • Hydrofluoric acid is a less acidic substance than hydrochloric acid, nitric acid, and sulfuric acid, but it is one of the most dangerous substances for humans. In recent years, it has become an indispensable substance in industries such as chemical plants and the semiconductor industry, and although it is a threat to the human body, its use is increasing for various purposes, and the amount of use is constantly increasing due to the expansion and development of the industry. The dangers of hydrogen fluoride have been highlighted since the 2012 accident, which led to a more than fivefold increase in management standards for handling facilities. Hydrogen fluoride converts to hydrofluoric acid when exposed to the air, which can be fatal to humans. This study simulates the effects of a release of a toxic substance in the workplace, even though a protection layer has been provided to minimize the damage caused by the released toxic substance, and recommend ways to control the risk to workers in the event of a release in the workplace.