• Title/Summary/Keyword: 누출액

Search Result 54, Processing Time 0.035 seconds

The Effects of Diluted Fibrin Glue about Continuous Air Leakage after Lung Surgery (폐수술 후 지속적 공기누출에 희석한 Fibrin Glue의 효과)

  • Choi Chang-Woo;Lee Seong-Jin;Lee Chol-Sae;Lee Kihl-Rho;Lee Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.770-774
    • /
    • 2006
  • Background: Continuous air leakage through chest tube after lung surgery may increase pt's hospital stay and lead to many complications including empyema etc. Chemical pleurodesis has frequently been used for prevention of air leakage. Therefore, we performed chemical pleurodesis using diluted fibrin glue in patients with continuous air leak-age and observed the effects and efficiency of treatment. Material and Method: From September, 2001 to August, 2005, 16 patients whose continuous air leakage lasted more than 7 days underwent chemical pleurodesis with diluted fibrin glue. The effects of treatment, complications and recurrences were reviewed. Dissolved fibrinogen 1.0 g and aprotinin 500,000 KIU were mixed in a 50 cc syringe (Mixed solution A). And dissolved thrombin 5,000 IU and Calcium chloride 600 mg were mixed in a 50 cc syringe (Mixed solution B). Cefazolin 1.0 g was mixed in a 50 cc syringe (Mixed solution C). Rubber tube was inserted between the chest tube and the collecting bottle. An inserted rubber tube was positioned 60cm above the patient and forming a loop appearance was done. Mixed solutions A, B and C were injected into the highest rubber tube. Results: Continuous air leakages disappeared in all f6 patients at next day. Chest tubes were removed after 3 days in all patients. Complications were chest pain in 12 patients (75%), leukocytosis in 14 patients (88%), fever and chill in 14 patients (88%). All complications were transient and disappeared without specific treatment. Conclusion: Our findings demonstrated that diluted fibrin glue chemical pleurodesis was effective in patients with continuous air leakage lasting more than 7 days. Diluted fibrin glue chemical pleurodesis had good results with acceptable complications. long term follow-up is necessary to evaluate the accurate effects of treatment and recurrence in a large number of patients.

Cause Analysis and Countermeasure of Tracking in Mobile Phone Charger (휴대폰 충전기 내 트래킹 발생 원인 분석 및 대책)

  • Park, Jin-Young;Kim, Jae-Hyun;Park, Kwang-Muk;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.71-77
    • /
    • 2016
  • The electrolyte of the capacitor in mobile phone chargers leaks to the power input terminal resulting in tracking on the PCB board to form a carbonized conductive path. As a result of structural analysis of the cause of the tracking, It occurred when the power input terminal and the PCB board were connected directly using the connector. The larger the amount of electrolyte leaked from the capacitor into the power input terminal, or the lower the height of the partition provided between the plug pins of the power input terminal, the higher the tracking occurrence rate. Accordingly, to lower the occurrence rate of tracking in the charger, it is necessary to provide a partition on the capacitor or increase the height of the partition provided on the power input terminal so that the leaked electrolyte does not flow to the power input terminal. In addition, the tracking occurrence rate will be reduced further if the shape of the PCB board touching ther power connection terminal is changed to ${\Pi}$.

A Study on the Release Rate of Hazardous Materials from Liquid Pipeline (액체배관으로부터 위험물질 누출속도 산정에 관한 연구)

  • Tak Song-Su;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.81-85
    • /
    • 2002
  • This paper presents the calculation methods of liquid release rate in the transition region when hazardous materials leak from the pipeline due to an unwanted accident. For the laminar and turbulent flow region, liquid release rate from a pipeline can be calculated by using a commercial software or by using calculator based on the models(equations) suggested by Crowl and Louvar et al. However, there has been no corresponding model for the transition flow region. In this paper. we showed that the turbulent model may be used as an equation generally used in the transition region for conservative hazard analysis if safety factor $30\%$ is added to the value calculated by the turbulent model. In this regard, we first calculated the release rate from liquid pipeline in the transition region by using experimental data on Fanning friction factor depending on Reynolds number which Lap-Mou Tam et al. had introduced, then compared it with that of the laminar and turbulent models in transition region.

  • PDF

A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire (지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석)

  • Lee Seung-Lim;Lee Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.19-23
    • /
    • 2003
  • The purpose of this thesis is to investigate the BLEVE probability of LP gas storage tanks which are relatively more dangerous, by the deductive calculating method using the results of Birk's pilot tank test and the required heat capacity of BLEVE. The result that BLEVEs can occur in only above 43.68 percent of liquid filling level under $600^{\circ}C$ of tank pate temperature and $53^{\circ}C$ of inner liquid temperature, was obtained and will be useful for preventing the BLEVE of LP gas storage tanks in fire sites. In addition, this research showed conditions of external leak and fire causing BLEVE, based on 15ton capacity of LP gas tank which has the same specifications as those in Puchon LP gas filling station accident. The result of the calculation is that the minimum pool fire conditions of BLEVE are above 7.2mm equivalent diameter under a liquid release condition and above 17.6mm equivalent diameter under a two-phase release condition. In the end, the result of calculating the pool size corresponding the above conditions using EFFECTS version 2.1, concludes that a minimum of 3.3 meters of diameter and 10.4 meters of height should be needed for BLEVE outbreak.

  • PDF

Sealing Ability of Root Canals Obturated with Gutta-percha, Epoxy Resin-based Sealer, and Dentin Adhesives (에폭시레진계 봉함제와 상아질접착제로 근관충전시 미세누출에 관한 연구)

  • Kim, Hee-Jung;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • 본 연구는 에폭시레진계 봉함제 (AH26)과 두 가지의 상아질 접착제와 함께 근관충전을 시 행하였을 때와 에폭시레진계 봉함제 단독으로 사용하였을 때의 미세누출을 혐기성 세균모델을 이용하여 평가하였다. 52개의 단근치를 이용하여 .04, .06 taper Profile (Dentsply-Maillefer, Ballaigues, Swiss)을 사용하여 변형된 crown-down pressureless법으로 근관형성 하였다. 형성된 치근을 12개씩 무작위로 나누어 4개의 실험군으로 하였으며, 나머지 치아 중 2개를 양성대조군에, 2개는 음성대조군으로 사용하였다. 제1군은 All Bond 2(Bisco, Itasca, IL, USA)를 적용하고 거타퍼쳐와 AH26 (Dentsply, Konstanz, Germany)을 이용하여 continuous wave of condensation technique으로 근관충전 하였으며, 제 2군은Prime & Bond NT (Dentsply, Konstanz, Germany)를 적용 후 거타퍼쳐와 AH26을 이용하여 충전하였으며, 제3군은 17% EDTA를 적용하여 도말층을 제거한 후 거터퍼쳐 와 AH26을 사용하여 충전하였다. 제4군은 17% EDTA를 적용하지 않고 거터퍼쳐와 AH26을 사용하여 충전하였다. Fusobacterium nucleatum (VPI 10197)을 추적자로 이용한 혐기성세균모델을 사용하여 혐기성배양기에서 배양시키면서 60일 동안 각군에 대한 미세누출 여부를 관찰하였다. 매일 배양액의 혼탁도와 색상변화를 관찰하여 기록하였다. 제4군에서 통계학적으로 유의할만한 미세누출을 가장 많이 보였으며(p<0.0005) 나머지 3개의 실험군에서는 서로간의 통계학적으로 유의할 만한 차이를 보이지 않았다. 주사전자현미경 관찰 시 제 1군과 제2군의 상아질 접착제가 상아세관으로 침투한 소견을 관찰 할 수 있었다.

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

Matrix Metalloproteinase-1 and Tissue Inhibitor of Metalloproteinase-1 levels in Exudative Pleural Effusions (삼출성 흉수에서 기질 금속단백분해효소-1과 금속단백분해효소의 조직억제제-1)

  • Cho, Jae Hwa;Nam, Jeong Hyeon;Lee, Kyum Ho;Yoon, Byeong Kab;Ryu, Jeong Sun;Kwak, Sung Min;Lee, Hong Lyeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.517-521
    • /
    • 2005
  • Background : The balances of the proteinases and antiproteinases system have been implicated in the pathogenesis of various exudative pleural effusions. The aim of this study was to examine the matrix metalloproteinase-1 (MMP-1) and tissue inhibitor of metalloproteinase-1 (TIMP-1) levels in exudative pleural effusions. Methods : The study included 33 tuberculous effusions, 17 malignant, and 5 transudates. The pleural levels of MMP-1 and TIMP-1 were determined using a commercially available ELISA assay. Results : The group of tuberculous effusions showed higher pleural MMP-1 levels than the malignant and transudates. The pleural TIMP-1 levels of the tuberculous and malignant effusions were higher than the transudates. Conclusion : Elevated pleural MMP-1 and TIMP-1 levels were found in tuberculous effusions.

The Consequence Analysis for Unconfined Vapor Cloud Explosion Accident by the Continuous Release of Gas-Liquid Flow (기-액흐름 연속누출에 의한 개방공간 증기운 폭발사고의 영향평가)

  • 장서일;이헌창;김태옥
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.35-43
    • /
    • 2002
  • For the unconfined vapor cloud explosion accident by the continuous release of gas-liquid flow of various saturated liquids in a vessel at ground level, overpressures were estimated and analyzed with various release conditions and materials by TNT equivalency model with vapor dispersion. We found that at same release conditions, overpressure showed n-heptane > xylene > n-hexane > toluene > n-heptane > benzene, respectively and that overpressure was increased with increasing the hole diameter and the storage pressure, but it was increased with decreasing the wind speed, the interested distance, and the vessel thickness.

The Effect of Carbon Dioxide Leaked from Geological Storage Site on Soil Fertility: A Study on Artificial Leakage (지중 저장지로부터 누출된 이산화탄소가 토양 비옥도에 미치는 영향: 인위 누출 연구)

  • Baek, Seung Han;Lee, Sang-Woo;Lee, Woo-Chun;Yun, Seong-Taek;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.4
    • /
    • pp.409-425
    • /
    • 2021
  • Carbon dioxide has been known to be a typical greenhouse gas causing global warming, and a number of efforts have been proposed to reduce its concentration in the atmosphere. Among them, carbon dioxide capture and storage (CCS) has been taken into great account to accomplish the target reduction of carbon dioxide. In order to commercialize the CCS, its safety should be secured. In particular, if the stored carbon dioxide is leaked in the arable land, serious problems could come up in terms of crop growth. This study was conducted to investigate the effect of carbon dioxide leaked from storage sites on soil fertility. The leakage of carbon dioxide was simulated using the facility of its artificial injection into soils in the laboratory. Several soil chemical properties, such as pH, cation exchange capacity, electrical conductivity, the concentrations of exchangeable cations, nitrogen (N) (total-N, nitrate-N, and ammonia-N), phosphorus (P) (total-P and available-P), sulfur (S) (total-S and available-S), available-boron (B), and the contents of soil organic matter, were monitored as indicators of soil fertility during the period of artificial injection of carbon dioxide. Two kinds of soils, such as non-cultivated and cultivated soils, were compared in the artificial injection tests, and the latter included maize- and soybean-cultivated soils. The non-cultivated soil (NCS) was sandy soil of 42.6% porosity, the maize-cultivated soil (MCS) and soybean-cultivated soil (SCS) were loamy sand having 46.8% and 48.0% of porosities, respectively. The artificial injection facility had six columns: one was for the control without carbon dioxide injection, and the other five columns were used for the injections tests. Total injection periods for NCS and MCS/SCS were 60 and 70 days, respectively, and artificial rainfall events were simulated using one pore volume after the 12-day injection for the NCS and the 14-day injection for the MCS/SCS. After each rainfall event, the soil fertility indicators were measured for soil and leachate solution, and they were compared before and after the injection of carbon dioxide. The results indicate that the residual concentrations of exchangeable cations, total-N, total-P, the content of soil organic matter, and electrical conductivity were not likely to be affected by the injection of carbon dioxide. However, the residual concentrations of nitrate-N, ammonia-N, available-P, available-S, and available-B tended to decrease after the carbon dioxide injection, indicating that soil fertility might be reduced. Meanwhile, soil pH did not seem to be influenced due to the buffering capacity of soils, but it is speculated that a long-term leakage of carbon dioxide might bring about soil acidification.

The effect of MTAD on the apical leakage of obturated root canals: an electrochemical study (MTAD의 치근단 누출에 미치는 영향에 대한 전기화학적 연구)

  • Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of newly developed endodontic root canal cleanser (MTAD) on the apical leakage of obturated root canal using an electrochemical method. Canals of 60 extracted single-rooted human teeth were prepared by using a crown-down technique with rotary nickel-titanium files. In Group 1 (positive control group) and 2 (negative centre) group), 5.25% NaOCl was used as a canal irrigant and no canal wall treatment was done. In group 3 only 5.25% NaOCl were used as canal irrigant, canal wall treatment and final rinse. In group 4, specimens were irrigated with 5.25% NaOCl, treated with 5 ml of 17% EDTA for 5 minutes and final rinsed with 5.25% NaOCl Specimens of group 5 were irrigated with 1 3% NaOCl and treated with 5 ml of MTAD for 5 minutes. All root canals are dried with paper points and obtuated with gutta-percha and AH plus as a sealer using a continuous wave of condensation technique except in the group 1. The electrical resistance between the standard and experimental electrodes in canals was measured over a period of 10 days. Rising of apical leakage with time was observed for all the groups. Group 4 and 5 showed lower apical leakage than group 3 but differences between the group 3, 4 and 5 were no statistical significance at any measurement time.