False Alarm Filtering Algorithm Development of Pipeline Leak Detection System using Flow Volume Balance (유량 밸런스 특성을 활용한 송유관 누유 감지 시스템의 오알람 필터링 알고리즘 개발)

  • Kim, Min-Sung;Kim, Hie-Sik;Jung, Hae-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.95-102
    • /
    • 2016
  • Pipeline is making the most use of transportation of petroleum products on the land. But due to tremendous accident or environmental disaster by oil pipeline leak or pipeline stolen, leak detection systems have been used for preventing it. Leak detection method based on negative pressure wave has been used at the long distance pipeline. But even if it has showed good leak detection quality, due to making a lot of false alarm, it has weak point that disturbs concentration to system. This study suggests algorithm and method of using volume balance to decrease false-alarm of pipeline leak detection system based on negative pressure wave.

Image Detection System for Leakage Regions of Hydraulic Fluid in Faring Press Machine (단조프레스기의 유압유 누유영역 영상 감지 시스템)

  • Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1557-1562
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid in terms of using the pan/tilt camera from a remote place is implemented. It finds the bounding boxes which are recognized with object regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the ratios of width and height of the bounding boxes and compactness of the leakage shape. Also, it performs noise removal and calibration for transition and rotation of image as a preprocessing process. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various sources of light.

  • PDF

Image Detection System for leakage regions of Hydraulic Fluid in Foring Press Machine (단조프레스기의 유압유 누유 영역 영상 감지 시스템)

  • Lee, Kyeong-Hwan;Bae, Sung-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.35-39
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid by the pan/tilt camera from a remote place is implemented. It finds the Minimum Boundary Rectangles(MBR) which are recognized with candidate leakage regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the width and height of MBRs and the area ratios of the MBRs and the candidate leakage regions. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various light conditions.

  • PDF

OF Cable Management System (OF 케이블 관리시스템)

  • Kim, Gwan-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.568-569
    • /
    • 2019
  • 20~30년 전부터 국내 지중송전선로에 OF(Oil Filled)케이블을 사용해 왔다. OF케이블은 오랜 시간동안 신뢰성을 화고하고 있으며, 전연파괴 사고를 미연에 방지할 수 있는 장점이 있지만 유지보수에 많은 어려움이 있고, 절연유에 의한 환경오염이 발생하며, 화재에 취약한 단점이 있다. 최근 20~30년 전에 설치된 OF케이블의 수명이 한계에 도달하면서 고장 위험성이 증가하고, 누유의 위험성이 도사리고 있다. 본 논문에서는 OF케이블 상태 진단방법에 있어서 절연유에 반응하는 필름센서를 활용하여 절연유 탱크의 연결부에서 누유현상을 감지하여 OF케이블 누유 관리시스템을 개발하자 한다.

  • PDF

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

The Implemention of RTD-l000A based on ARM Microcontroller (ARM 마이크로컨트롤러 기반 RTD-1000A의 구현)

  • Kim, Min-Ho;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.6
    • /
    • pp.117-125
    • /
    • 2008
  • With increase of concern about the Ubiquitous application, the necessity of the computer system which is miniaturized is becoming larger. The ARM processor is showing a high share from embedded system market. In this paper, ideal method for RTD-1000 controller construction and development is described using ARM microcontroller. Existing RTD-1000 measures distance of disconnection or defect of sensing casket by measuring receiving reflected wave which was sent via copper wire inside the leaking sensing rod. Using this RTD-1000, leakage and breakage of water and oil pipe can be sensed and it reports damage results to the networks. But, existing RTD-1000 wastes hardware resources much and costs a great deal to installation. Also, it needs a cooling device because the heating problem, and has some problem of the secondary memory unit such as the hard disk. So, long tenn maintenance has some problems in the outside install place. In this paper, for the resolving the problem of RTD-1000, RTD-1000A embedded system based on ARM is proposed and simulated.

  • PDF

Development of an On-line Intelligent Embedded System for Detection the Leakage of Pipeline (실시간 누수 감지 가능한 매립형 지능형 배관 진단 시스템)

  • Lee, Changgil;Kim, Tae-Heon;Chang, Hajoo;Park, Seunghee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.94-94
    • /
    • 2011
  • 배관 구조물에서는 내부 미세 균열에서부터 국부 좌굴, 볼트 풀림, 피로 균열 등과 같이 다양한 형태의 손상이 복합적으로 발생 가능하다. 이러한 복합 손상은 배관 구조물의 누수, 누유 등의 사고를 야기할 수 있다. 하지만 기존의 단일 스케일 계측 시스템으로부터 복합 손상에 의한 실시간 누수를 진단하기는 매우 어렵다. 본 연구 단계에서는 누수를 야기하는 복합 손상을 효율적으로 진단하기 위하여 선행 연구에서 제안된 압전센서를 이용한 자가 계측 회로 기반의 다중 스케일 계측 시스템을 구조물의 복합 손상 진단에 적용하였다. 자가 계측 회로 기반 다중 스케일 계측 시스템은 크게 두 가지 형태의 신호를 계측한다. 첫 번째 스케일은 임피던스 계측으로부터 특정 주파수 대역폭에 대한 구조 응답을 계측하며, 두 번째 스케일은 유도 초음파 계측으로부터 단일 중심 주파수에 해당하는 구조물의 응답을 계측한다. 복합 손상을 손상 유형별로 분류하기 위하여 E/M 임피던스(Electro-mechanical impedance)및 유도 초음파(Guided wave) 계측으로부터 추출한 특성을 이용하여 2차원 손상지수를 계산하고 이를 지도학습 기반 패턴인식 기법(Supervised learning based pattern recognition) 중 확률론적 신경망 기법(Probabilistic Neural Network, PNN)에 적용한다. 제안된 기법의 적용성 검토를 위하여 파이프 구조물에 인위적으로 다중 손상을 생성시켜 시험을 수행하였다. 본 연구에서 제안된 기법이 실제 배관 구조물에 성공적으로 적용된다면 손상 부재의 거동 및 구조물 성능의 손상에 대한 영향을 효율적으로 진단하고 평가함으로써 배관 구조물의 효과적인 유지관리가 가능할 것으로 예상된다.

  • PDF

A Study on the Performance Prediction of Fire Extinguish System in Aircraft Engine Bay (항공기 엔진베이 내 소화장치 성능예측을 위한 연구)

  • Park, Young-Ha;Kim, Hyung-Sik;Kim, Jin-Han;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.718-725
    • /
    • 2012
  • Fuel or oil which is leaked into the aircraft engine bay can make a fire when it is contacted to the engine surface of hot temperature. In order to avoid fire, the fire extinguish system should be designed so that the extinguishing agent is quickly injected and its concentration keeps higher in the fire protection region. FAA requires that the extinguishing agent injected within the fire protection region should be sustained longer than 0.5 second on keeping a higher concentration than 6%. For developing a fire protection system satisfying the FAA regulation, numerical and experimental studies for the injection time and the concentration of the extinguishing agent were conducted. These results showed similar trend for the injection time or concentration, but the data acquisition was delayed due to the response of the sensors in the experiment.