• Title/Summary/Keyword: 누수 시험

Search Result 147, Processing Time 0.022 seconds

The Effect of Soil Conditioners on the Growth of Rice and Soil Properties of Sandy Paddy Soils (수종객토원(數種客土源) 처리(處理)에 의(依)한 사질답토양(砂質畓土壤)의 특성변화(特性變化)와 수도생육(水稻生育)에 미치는 영향(影響))

  • Cho, Kang-Jin;Jung, Yeun-Tae;Choi, Jyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.3
    • /
    • pp.224-231
    • /
    • 1984
  • Four kinds of soil conditioners, such as red earth, clayey tidal deposit, silty tidal deposit and tertiary deposit were evaluated for the rice growth and for the effectiveness of soil improvement in sandy paddy soil (Gangseo series) whose percolation and nutrient leaching are usually severe. Experiment was conducted at the farmer's field in Hackpo Ri, Bugog Myeon, Changyeong Gun, Gyeong Nam Province for two years (1980-1981) with using two rice varieties, Milyang 42 for 1980 and cheongcheongbyeo for 1981. For both experimental years, the grain yields were increased on the plots that were treated with soil conditioners compared with nontreated plot. The increase in grain yield was particularly high on the plots treated with clayey tidal deposit and teritary deposit. The dry weight of the plant and the uptake amount of inorganic ingredient tended to increase on the plots of clayey tidal deposit and tertiary deposit during whole rice growing season because of the residual effect of soil conditioners in the second experimental year. Cation exchange capacity, available silicate, exchangeable potassium and active iron was increased by the treatment with the soil conditoners. Especially cation exchange capacity was highest in the tertiary deposit treatment plot. Aggregation content and plastic index were increased for the all treatment plots with soil conditioner, however, hydraulic conductivity was conspicuously decreased by the tertiary deposit and clayey tidal deposit treatments.

  • PDF

Monitoring of grout material injected under a reservoir using electrical and electromagnetic surveys (전기비저항 및 전자탐사를 이용한 저수지 하부에 주입된 그라우트 재료의 모니터링)

  • Suzuki, Koichi;Oyama, Takahiro;Kawashima, Fumiharu;Tsukada, Tomoyuki;Jyomori, Akira
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • In order to reduce leakage from a reservoir, a large amount of cement milk (grout) was injected from boreholes drilled around the shores of the reservoir, and monitored to establish the infiltration of cement milk into the bedrock under the reservoir. From laboratory tests using rock core samples, it was revealed that the resistivity of cement milk is much lower than that of the groundwater at this location. Therefore, it was expected that the resistivity of the zones filled with cement milk would be significantly reduced. Geophysical surveys are expected to be suitable methods to check the effectiveness of grouting in improving the water-retaining performance of a reservoir. DC electrical surveys (seven in total) and two Controlled Source Audio-frequency Magneto-Telluric (CSAMT) surveys were conducted along survey lines in the reservoir to monitor the infiltration of cement milk during the grouting. Extremely low resistivity zones ($10\;{\Omega}m$ or less) were observed in resistivity sections obtained by 2D inversion. The zones are inferred to be fractured zones filled with cement milk. In sections showing the rate of change of resistivity, three zones that showed significant change showed gradual expansion to deeper parts as the grouting progressed. These zones correspond to highly permeable zones detected by Lugeon tests at grout boreholes. We have confirmed that it is possible to measure the resistivity change by DC electrical and CSAMT surveys from the surface of the reservoir. It seems that such monitoring results could be reflected in future grouting plans.

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

Joint Displacement Resistance Evaluation of Waterproofing Material in Railroad Bridge Deck (철도교량상판 방수재료 선정을 위한 균열거동저항 성능평가)

  • Bae, Young-Min;Oh, Dong-Cheon;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.683-692
    • /
    • 2020
  • A joint displacement resistance evaluation method for selecting waterproofing materials in railway bridge decks is proposed. The displacement range for an evaluation is determined by finite element method (FEM) analysis of a load case based on an existing high-speed PSC Girder Box railroad bridge structure. The FEM analysis results were used to calculate the minimum joint displacement range to be applied during testing (approximately 1.5 mm). For the evaluation, four commonly used waterproofing membrane types, cementitious slurry coating (CSC), polyurethane coating system (PCS), self-adhesive asphalt sheet (SAS), and composite asphalt sheet (CAS), were tested, with five specimens of each membrane type. The joint displacement width range conditions, including the minimum displacement range obtained from FEM analysis, were set to be the incrementing interval, from 1.5, 3.0, 4.5, and 6.0 mm. The proposal for the evaluation criteria and the specimen test results demonstrated how the evaluation method is important for the sustainability of high-speed railway bridges.

Performance Evaluation of Concrete using Performance Improving-type Polycarboxylic acid-based Admixture (성능개선형 폴리카르본산계 혼화제를 사용한 콘크리트의 성능평가에 관한 실험적 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae;Gong, Min-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.445-451
    • /
    • 2017
  • Because of the supply-demand problem of aggregate, recently, the construction sites using 100% crushed sand are increasing and the use of low quality aggregate such as farmland sand is increasing too. When the low quality aggregate is used, the various quality defect of concrete such as the strength reduction, the increase of shrinkage and bleeding can be occurred. Therefore, in this study, the performance improvement PC admixture was developed to minimize the quality defect of plain concrete of basement parking area, when the low quality aggregate was used at the plain concrete of basement parking area. The slump loss to elapsed time test, the compressive strength test, the bleeding test and the drying shrinkage test were carried out.

A Study on the Seismic Performance Design of Waterproofing Materials Applied Single-side Walls on Underground Structures (지하 구조물 외벽에 적용되는 방수재료의 구조체 거동 및 진동 대응 성능 설계 제안 연구)

  • Kim, Soo-Yeon;Kim, Meong-Ji;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.43-50
    • /
    • 2020
  • In this study, the possibility of seismic performance design was proposed and the quality verification test method was reviewed as part of the design of waterproof performance in underground walls under accelerated environment conditions for waterproofing materials, which are barrier and finishing material that can prevent ingress or overflowing water from inside and outside of a building by attaching all of the construction materials used in construction structures. Considering the current state of earthquake-resistant design of construction materials in Korea and abroad, seismic product groups are rare and mostly dependent on construction methods because there are no regulations on materials, although there are still regulations on earthquake-resistant design in the building process under the current law. Overseas, it was possible to confirm that various building materials that gave seismic performance to non-structural materials, such as Japan, Canada, and Germany, are being developed. If it is possible to have a complementary response to earthquakes in the advanced external waterproofing materials, it can be expected to be applicable as leak prevention and prevention technology along with the seismic designed structure.

Optimum Rates of N. Absorbed Zeolite to be Applied under the Water Percolation Adjusted Sand Paddy Soil (사질답토양(砂質沓土壤)에서 투수속도조절(透水速度調節)과 질소흡착(窒素吸着) Zeolite의 시비량(施肥量)에 관(關)한 연구(硏究))

  • Ahn, Sand-Bae;Park, Jun-Kyu;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 1987
  • A pot experiment was conducted to find out the effectiveness of ammonium sulfate absorbed Zeolite on the yield of rice and the changes of some plant nutrients under the condition of two levels of water percolation. The results were as follows: 1. Unhulled rice yield was increased in the plot of the percolation of 10 mm/day than the percolation of 30 mm/day due to the increase of panicle number and ripening ratio. 2. $NH^+_4-N$, $K^+$ and $SiO_2$ concentration in soil leachates were lower in the percolation rate of 10 mm/day than in the early stage of rice growth were decreased by the application of Zeolite 1.0 T/10a. 3. Plant uptakes of K and N in the harvesting stage were more accelerated in the percolation of 10 mm/day comparing with the percolation of 30 mm/day, and the silica uptake of plant was the reverse against the case of former elements. 4. The optimum rates of Zeolite for maximum yield were about 1T/10a.

  • PDF

A Study on the Development of Long-term Self Powered Underground Pipeline Remote Monitoring System (자가 발전형 장기 지하매설배관 원격감시 장치 개발에 관한 연구)

  • Kim, Youngsear;Chae, Hyun-Byung;Seo, Jae-Soon;Chae, Soo-Kwon
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.576-585
    • /
    • 2018
  • Systematic management during the whole life cycle from construction to operation and maintenance is very important for the seven underground pipelines (waterworks, sewerage, electricity, telecommunications, gas, heating, oil including waterworks and sewerage). Especially, it is the construction process that affects the whole life cycle of underground buried pipeline. In order to construct a new city or to maintain different underground pipes, it is always necessary to dig the ground and carry out construction and related work. There is a possibility that secondary and tertiary breaks frequently occur in the pipeline construction process after the piping constructed first in this process. To solve this problem, a system is needed which can monitor damage in real time. However, the supply of electric power for continuous operation of the system is limited according to the environment of underground buried pipelines, so it is necessary to develop a stable electric power supply system using natural energy rather than existing electric power. In this study, we developed a system that can operate the pipeline monitoring system for long time (24 hours and 15 days) using natural energy using wind and solar light.

Characteristics of defect on segmental lining of TBM tunnel in operational subway (운용중인 국내 지하철 TBM터널의 세그먼트라이닝 결함특성 분석)

  • Choo, Jinho;Lee, DongHun;Noh, EunChul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.109-128
    • /
    • 2022
  • The precise inspection for safety and diagnosis (PISD) of tunnel has been conducted by the special act on safety control of public structures. However, the present assessment for the segmental lining of TBM tunnel has limitation such as: NDTs for integrity, segmental configuration for field inspection, and consideration for jacking system. Even if the number of TBM tunnel is less than 1% of enrolled facility in FMS, more attention to maintenance should be necessary due to its usage such as multi-use facility and national important facility. Compared to NATM tunnel, excavated by drilling and blasting and then installed lining by cast-in-place within 6~12 m, TBM tunnel is cut out ground by disk and cutter-bit and then assembled 7 pieces of precast segment, 1.2~1.4 m wide. Different features of design, construction, and maintenance should be considered to be more exact evaluation of TBM tunnel. The characteristics of defect is categorized and analyzed with 11 operational TBM tunnels in domestic subway. To be more comprehend various particular defects, foreign studies have been also adapted. Crack and leakage are categorized in 7 patterns. Breakage/spalling and corrosion are also grouped into 3 patterns. Patterned defects or damages are fed back in design, construction, and are useful guidelines for maintenance stage in future.