• Title/Summary/Keyword: 누수저항

Search Result 79, Processing Time 0.026 seconds

Hydraulic Resistance Characteristics of Compacted Weathered Granite Soil by Rotating Cylinder Test and Image Analysis (영상처리기법과 회전식 수리저항성능 실험을 이용한 다짐화강풍화토의 수리저항특성 분석)

  • Kim, Young Sang;Lim, Jae Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.25-34
    • /
    • 2016
  • Recently, in Korea, problems related with unstability of slope or sinkhole in urban area due to erosion of compacted granite soil which was used as a backfill or embankment material have been treated as important issues. Small hole might develop inside of backfill area due to erosion of not only weathered granite soil but also clay, silt, fine sand size particles when underground water flows. Once erosion starts in a soil mass, erosion rate increases gradually to cause rapid destruction. In this study, a rotating cylinder test (RCT) was performed to evaluate the hydraulic resistance characteristics of compacted weathered granite soil under various relative densities and preconsolidation pressures. Meanwhile, an image analysis method was introduced to analyze radius of irregularly eroded sample. It was found that image analysis is an effective means of minimizing the error in calculating a critical shear stress and threshold shear stress on the irregularly eroded sample. Furthermore, in general, hydraulic resistance capacity increases with the increase of relative density and preconsolidation pressure.

Joint Displacement Resistance Evaluation of Waterproofing Material in Railroad Bridge Deck (철도교량상판 방수재료 선정을 위한 균열거동저항 성능평가)

  • Bae, Young-Min;Oh, Dong-Cheon;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.683-692
    • /
    • 2020
  • A joint displacement resistance evaluation method for selecting waterproofing materials in railway bridge decks is proposed. The displacement range for an evaluation is determined by finite element method (FEM) analysis of a load case based on an existing high-speed PSC Girder Box railroad bridge structure. The FEM analysis results were used to calculate the minimum joint displacement range to be applied during testing (approximately 1.5 mm). For the evaluation, four commonly used waterproofing membrane types, cementitious slurry coating (CSC), polyurethane coating system (PCS), self-adhesive asphalt sheet (SAS), and composite asphalt sheet (CAS), were tested, with five specimens of each membrane type. The joint displacement width range conditions, including the minimum displacement range obtained from FEM analysis, were set to be the incrementing interval, from 1.5, 3.0, 4.5, and 6.0 mm. The proposal for the evaluation criteria and the specimen test results demonstrated how the evaluation method is important for the sustainability of high-speed railway bridges.

Case Study of Improvement against Leakage of a Sea Dike under Construction (해안제방 시공 중 해수유입에 대한 차수보강 사례분석)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Kim, Hong-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • In this study, the causes and countermeasures for the leakage of a sea dyke under construction are analyzed. In general, the seabed ground is clearly divided from the embankment but a lot of parts show abnormal zones with low resistivity from the results of electric resistivity survey. Hence the causes of the leakage are considered as following: three-dimensional shear strain behavior, irregular compulsory replacement of the soft seabed ground with low strength and quality deterioration of the waterproof sheets during the closing process. The improvement method is determined by considering the constructability in the seawater and its velocity condition, durability, economic feasibility, similar application cases and so on. Consequently, a combination of low slump mortar and slurry grouting and injection method is selected as an optimum combination. Mixing ratio and improvement pattern are determined after drilling investigation and pilot test. The improvement boundary is separated into general and intense leakage area. The construction is performed with each pattern and the improvement effects are confirmed. The confirmed effects with various tests after completion show tolerable ranges for all of the established standards. Finally, various issues such as prediction of length of the waterproof sheet, installation of it against seawater velocity, etc. should be considered when sea dykes are designed or executed around the western sea which has high tide difference.

A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (1) (필댐의 안정성 해석 연구 (1))

  • HoWoongShon;DaeKeunLee
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.165-177
    • /
    • 2003
  • The purpose of this paper is to analyze the behavior and to study the safety evaluation of the Unmun Dam located in Cheongdo-Gun of GyeongBuk Province, Korea. For this purpose, soil analyses including boring data, geophysical surveys were conducted. In this paper, especially many geophysical methods were adopted to configure out the subsurface situation of dam. Applied geophysical methods were: 1) electric resistivity survey, 2) high frequency magnetotelluric (HFMT) survey, 3) ground penetrating radar (GPR) survey, 4) seismic refraction survey, 5) seismic cross-hole tomography survey, and 6) high frequency impedance (ZHF) survey. Each of geophysical surveys were analyzed and joint analyses between geophysical surveys were also performed to deduce the more reliable subsurface information of Dam by using the features and characteristics of each geophysical survey. Since many defects, such as gravel and weathered rock blocks in the dam core, and lots of amounts of leakage, by boring analyses were found, reinforcement by compaction grouting system (CGS) has been conducted in some range of dam. Some geophysical data and data of geotechnical gauges were also used to confirm the effects of reinforcement. Electric resistivity, EM, GPR, ZHF, seismic refraction and seismic tomography surveys show that left side of dam is weak, which means the possibility of existence of gravel, rock block, water and cavities in the core of dam. This result coincides with the boring data. Especially, electric survey after reinforcement shows that even the right side of the dam has been deformed by the strong pressure during the reinforcement itself. As a conclusion, some problems in the dam found. Especially, the dam near spillway shows the high possibility of leakage. It should be pointed out that only the left side of he dam has not a leakage problem. As a whole, the dam has problems of weakness, because of unsatisfactory construction. It is strongly recommended that highly intensive monitoring is required.

  • PDF

A preliminary study of watertightness and salt water resistance of spray-applied membrane (뿜어붙임멤브레인의 방수성능 및 염수저항성의 기초평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho;Lee, Cheol-Ho;Kim, Jintae;Choi, Myung-Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.283-299
    • /
    • 2017
  • The leakage of tunnel causes the long-term durability of the structures such as concrete lining to deteriorate. The cause of durability degradation can be various substances contained in groundwater such as chloride, sulphate, water, and gas. In this study, a series of test were carried out to determine the watertightness performance and the resistance to salt water of the spray-applied membrane used as non-structural rock support or as a waterproof material for tunnels. As a result, it was found that the penetration of water could occur in a specimen, and the reason was that the internal pores generated by the mixing of the liquid polymer and the powder material and the internal pores were connected by the water pressure. The tensile strength of the test specimens immersed in distilled water and saline water was found to be reduced to less than half of the tensile strength in normal condition. In addition, The elongation was measured to be higher in distilled water than in salt water. However, this result will require further investigation.

Studies on Controlling Mixed Annual and Perennial Weeds in Paddy Fields - On the Herbicidal Properties of Perfluidone - (수종(數種) 다년생잡초혼생답(多年生雜草混生沓)에 있어서 제초제(除草劑)에 의한 효과적(效果的)인 잡초방제(雜草防除) - Perfluidone의 작용특성구명(作用特性究明)을 중심(中心)으로 -)

  • Ryang, H.S.;Han, S.S.
    • Korean Journal of Weed Science
    • /
    • v.3 no.1
    • /
    • pp.75-99
    • /
    • 1983
  • The herbicidal properties of perfluidone [1,1,1-trifluoro-N-2-methyl-4-(phenylsulponyl) phenyl methanesulfonamide] were investigated in pots and paddy fields. At the rate of 2.0kg prod./10a, perfluidone did not cause any injury to the 4 leaf stage (LS) rice seedlings. Although the crop injury increased with increasing the application rate, the injury caused by 16kg prod. perfluidone/10a gave rise to only 30% yield reduction. The crop injury was greatest when perfluidone was applied 2 days before transplanting and decreased as the application time delayed. Perfluidone showed greater crop injury to the 3 LS seedlings, at more than 7cm water depth, and at high temperature than to the 4 LS seedlings, at 3-5cm water depth, and at low temperature. Indica and indica ${\times}$ japonica rice varieties were generally more sensitive to perfluidone than japonica rice variety. Perfluidone effectively controlled most of annual weeds and such perennial weeds as Sagittaria pygmaea MIQ., Potamogeton distinctus A. BENN, Cyperus serotinus ROTTB, Scirpus maritimus L., Eleocharis kuroguwai OHWL, and Scirpus hotarui OHWL, whereas Sagittaria trifolia L. and Polygonum hydropiper SPACH. were tolerent to perfluidone. The weeding effect decreased with increasing the leaching amount of water and the overflowing of irrigated water within 24 hours after the herbicide application. When the application time was done later than 8 days after transplanting, the perennial weeds were shown at deeper soil layers, and the standing water was deeper than 7cm, the effect tended to decrease. However, there was no difference in the weeding effect between soil types. Downward movement of perfluidone in flooded soil ranged from 2 to 8cm deep. The movement increased with increasing the leaching amount of water and the application rate and at a sandy loam soil which possessed less adsorptive capacity. Residual effect of perfluidone was found at 35 to 80 days after application, which varied such factors as Soil types. Increase in the leaching amount of water resulted in decrease in the period of the residual effect. The period was shorter at non-sterilized soil than at sterilized soil. The 0.75kg ai perfluidone + 1.5kg ai SL-49 (1,3-dimethyl-6-(2,4-dichlor-benzoyl)-5-phenacyloxy-pyrazole)/ha and 1.5kg ai perfluidone + 1.05kg ai bifenox (2,4-dichlorophenyl-3-methoxy carbonyl-4-nitro phenyl ether)/ha showed less crop injury than 1.5kg ai/ha perfluidone alone. However, the weeding effect of the former was similar to that of the later.

  • PDF

고온 물에서 304 와 600 합금의 입계응력부식균열(IGSCC)의 상이성과 유사성

  • 권혁상;김수정
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.22-22
    • /
    • 1998
  • 304 는 BWR(boiling water reactor)의 reactor 구조용 재료로 사용되고 있고, 합금 600 은 PWR(pressurized water reator) 의 증기 발생기 세관으로 쓰이고 있으며 모두 약 $280{\;}^{\circ}C$ 이상 의 원자로 냉각수에 노출되어 있다. 원자로 냉각수 분위기에서 두 합금의 공통적인 특정은 입계응력부식균열(IGSCC)에 민감한것과 IGSCC가 예민화(sensitization)와 관련이 있는 것이 다. 두 합금에서 일어나는 IGSCC는 원자력발전소의 부식피해중 가장 빈도가 높고 발생시 방사능 누출로 인하여 원전의 신뢰성을 저하시키고, 가동중단으로 인한 경제적 손실을 초 래하여 지난 20 년 동안 가장 심도있게 연구된 주제다. 304 은 크롬 탄화물의 업계 석출로 언하여 예민화된경우 IGSCC 에 민감한 반면 600 은 예민화된 경우 뿐만 아니라 용체화처리된 상태에서도 IGSCC에 민감하다. 오히려 600은 용 체화처리 후 700 C에서 15~20시간 시효처리를 하여 크롬탄화물을 업계에 석출 시커었을 때 IGSCC 저항성이 향상된다. 두 합금의 IGSCC 특정 중 큰 차이는 304는 임계균열전위 ( (critical cracking potential) 이 존재하여 부식전위(corrosion potential) 가 엄계균열전위보다 낮 은 경우 IGSCC 가 일어나지 않지만 그 반대인 경우 IGSCC 에 민감하게된다. 반면에 600 은 뚜렷한 임계균열전위가 존재하지 않고 양극 분극(anodic polarization) 뿐만 아니라 음극분극 시에도 IGSCC 가 일어난다. 이련 이유로 600의 IGSCC 가구로 피막파괴-양극용해(film rupture-anodic dissolution)외에 수소취성(hydrogen embrittlement)기구도 제안되고 었다. 원전의 냉각수는 고 순도의 물이지만 수 처리 과정과 웅축기 배관의 누수로 인한 산소, $Cu^{2+},{\;}S_xO_6{\;}^{2-}(x=3~6)$ 등이 유입되어 오염되는데 이려한 오염물질들이 수 ppm정도 소량 포함된 경우 응 력부식민감도는 상당히 증가된다. 산성분위기 흑은 산소, $Cu^{2+}$, 등이 소량 포합된 산화성 분위기 그리고 sufur oxyanion 에 오염된 고온의 물에서 600 의 IGSCC 민감도는 예민화도가 증가할 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.

  • PDF

Investigation on Products and Regulation of Flexible Adhesive Rubber Asphalt Type Sealant for the Development of Korea-China Joint Standard (점착유연형 고무아스팔트계 씰재의 한중 공동 품질관리 규정 개발을 위한 제품 및 기술기준 현황 조사)

  • An, Ki-Won;Kim, Dong-Bum;Choi, Su-Young;He, Xing-Yang;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.323-332
    • /
    • 2019
  • Non-curable rubberized polymer asphalt waterproof coating materials in Korea and China are manufactured without advanced quality control techniques and common standard, And they are exposed consistent water leakage problems. Import and application of Korean waterproofing products and installation methods is difficult in the present situation as the Chinese standard(JC/T 2428) is different in nature with the Korean counterpart products, And quality assurance is inevitable based on mutual standards. In order to resolve this issue, alternatives such as using standards provided by the ISO (International Organization for Standardization) are generally employed, but there is no such ISO standard as a waterproof material for non-curable rubberized polymer asphalt material. Furthermore, it is unreasonable to develop the ISO standard for rubber asphalt seals for exchange in terms of time and cost. This study proposes that the establishment of a quality standard that can be applied for both countries will be required via an joint international standard that outlines the properties of materials if applied in mutual trade exchange.

An Experimental Study on the Structural Performance of Lateral Resistance in Steel Elevator Pit (강재엘리베이터 피트 측압저항 구조성능에 관한 실험적 연구)

  • Hong, Seong-Uk;Kim, Tae-Soo;Baek, Ki-Youl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • Steel elevator pit was developed for the purpose of minimizing the excavation, simplifying the construction of the frame and economical efficiency by improving the problems that occurred in the existing reinforced concrete. It is common to apply conventional RC method through excavation to underground structures such as underground floor collector well and elevator pit. In recent years, the use of steel collector well and steel elevator pits to reduce construction costs by minimizing the materials of steel and concrete has been continuously increasing. The steel elevator pit is an underground structure and then the performance of the welding part and the structure system is important. Specimen with only steel plate and concrete without studs could support the load more than 3 times than the specimen with deck only. Therefore, even if there is no stud, the deck (steel plate) rib is formed and the effect of restraining the steel plate and the concrete during the bending action can be expected. However, since sudden fracture in the elevator pit may occur, stud bolt arrangement is necessary for the composite effect of steel plate and concrete. It is expected that the bending strength can be expected to increase by about 15% or more depending with and without stud bolts.

Inspection Method Validation of Grouting Effect on an Agricultural Reservoir Dam (농업용 저수지 제체에서의 그라우팅 주입효과 확인방법의 검증)

  • Kim, Hyeong-Sin;Moon, Seong-Woo;Leem, Kookmook;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.381-393
    • /
    • 2021
  • Physical, mechanical, hydraulic, and geophysical tests were applied to validate methods of inspecting the effectiveness of grouting on an agricultural reservoir dam. Data obtained from series of in situ and laboratory tests considered four stages: before grouting; during grouting; immediately after grouting; and after aging the grouting for 28 days. The results of SPT and triaxial tests, including the unit weight, compressive strength, friction angle, cohesion, and N-value, indicated the extent of ground improvement with respect to grout injection. However, they sometimes contained errors caused by ground heterogeneity. Hydraulic conductivity obtained from in situ variable head permeability testing is most suitable for identifying the effectiveness of grouting because the impermeability of the ground increased immediately after grouting. Electric resistivity surveying is useful for finding a saturated zone and a seepage pathway, and multichannel analysis of surface waves (MASW) is suitable for analyzing the effectiveness of grouting, as elastic velocity increases distinctly after grouting injection. MASW also allows calculation from the P- and S- wave velocities of dynamic properties (e.g., dynamic elastic modulus and dynamic Poisson's ratio), which can be used in the seismic design of dam structures.