• Title/Summary/Keyword: 누수저항

Search Result 79, Processing Time 0.025 seconds

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

A Study to Estimate the Seawater Leakage Zone of the Embankment using SP and Pole-pole Array Resistivity Survey (SP 및 단극배열 전기비저항탐사를 이용한 방조제 누수지점 탐지)

  • Song Sung-Ho;Lee Kyu-Sang;Kim Jin-Ho;Jang Eui-Woong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.19-40
    • /
    • 2000
  • We applied both SP monitoring and pole-pole array resistivity surveys and SP survey and dipole-dipole array resistivity survey to leakage problems in several embankments and dike, respectively, to estimate and detect the zone of leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. According to this situation, SP monitoring and resistivity survey using pole-pole electrode array, which is relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity(EC) and temperature variations along the inner part of the embankment to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincide with tidal variations at each embankment. Based on the survey results, it is concluded that both SP monitoring and the pole-pole array resistivity method are quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

Application of Geophysical Exploration Methods to Seepage Bone Investigation of Dam Structures (제방누수조사에의 물리탐사기법의 활용(쌍극자배열 전기비저항탐사와 SP탐사를 중심으로))

  • Won Jong-Geun;Song Sung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.240-257
    • /
    • 1999
  • More than 16 percent of the total 18,032 reservoirs over the country were reported to have leakage problems and need to be improved. Recently, a great deal of progress was made in geophysical survey techniques, particularly in electrical resistivity, and the techniques are used for variety of Purposes in groundwater and dam management due to its economical advantages. This document describes the re-evaluation of existing resistivity data including newly surveyed data, mapping of modeled value in 2-D analysis to locate seepage pathways, This contains also discussion results of more than eighteen years of professional experiences in the field of dam efficiency improvement. In comparison of surface resistivity data with several soil analysis data in laboratory, it is evident that the surface resistivity value shows a qualitative proportionality with the sand contents of the filling materials in earth dam. The result from the study also indicates that the SP method in subsurface investigation is effective to detect seepage in earth filled dam as well as piping through rock/earthfill dike.

  • PDF

Time-lapse Inversion of 2D Resistivity Monitoring Data (2차원 전기비저항 모니터링 자료의 시간경과 역산)

  • Kim, Ki-Ju;Cho, In-Ky;Jeoung, Jae-Hyeung
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.326-334
    • /
    • 2008
  • The resistivity method has been used to image the electrical properties of the subsurface. Especially, this method has become suitable for monitoring since data could be rapidly and automatically acquired. In this study, we developed a time-lapse inversion algorithm for the interpretation of resistivity monitoring data. The developed inversion algorithm imposes a big penalty on the model parameter with small change, while a minimal penalty on the model parameter with large change compared to the reference model. Through the numerical experiments, we can ensure that the time-lapse inversion result shows more accurate and focused image where model parameters have changed. Also, applying the timelapse inversion method to the leakage detection of an embankment dam, we can confirm that there are three major leakage zones, but they have not changed over time.

Development of the Water-leakage Detection Method Through the Geophysical Test on the Artificial Ground (모의지반 실험을 통한 누수영역 탐지기술 개발)

  • Kwon, Hyoung-Seok;Mitsuhata, Yuji;Uchida, Toshihiro
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.3
    • /
    • pp.39-46
    • /
    • 2009
  • A small loop-loop multi-frequency electromagnetic(EM) induction method is a useful technique to map a resistivity distribution efficiently and non-destructively. However, for quantitative interpretation and depth sounding, the quality of measured data is crucial. In this paper, we propose a bias correction of measured data by using background noise measurements to obtain reliable data, and propose an evaluation technique of apparent that can provide a resistivity image easily. We have performed small loop-loop EM measurements to detect water saturation in a man-made test site. The application of our proposed techniques to the measured data was successful.

  • PDF

Applicability of Geophysical Prospecting for water leakage detection in water utilization facilities (수리시설물의 누수탐지를 위한 물리탐사의 적용성)

  • Park Sam-Gyu;Song Sung-Ho;Choi Jong-hak;Choi Bo-Gyu;Lee Byoung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.179-195
    • /
    • 2002
  • This paper examined the applicability of geophysical prospecting for water leakage detection of the water utilization facilities. Electrical resistivity survey and spontaneous-potential survey were carried out for the water leakage detection of dike and embankment, and the applicability was confirmed from many case studies. However, in order to efficiently maintain and detection of the more accurate water points in the embankment, the efficiently maintain and detection of the more accurate water leakage points in the embankment, the requirements are as follows; 1) It is necessary to use the electrical resistivity survey jointly with the spontaneous-potential survey in order to improve the reliability of water leakage information. 2) It is important to understand physical properties of the soil which influences the electrical resistivity of embankment in order to accurately grasp the water leakage points from the result of the electrical resistivity survey. 3) It is necessary to introduce the three-dimensional prospecting in order to improve the reliability of the measured value. 4) Introductions of the monitoring measurement system are necessary in order to efficiently and economically maintain of the water utilization facilities.

  • PDF

Distortion of Resistivity Data Due to the 3D Geometry of Embankment Dams (저수지 3차원 구조에 의한 전기비저항 탐사자료의 왜곡)

  • Cho, In-Ky;Kang, Hyung-Jae;Kim, Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.291-298
    • /
    • 2006
  • Resistivity method is a practical and effective geophysical technique to detect leakage zones in embankment dams. Generally, resistivity survey conducted along the crest assumes that the embankment dam has a 2D structure. However, the 3D topography of embankments distorts significantly resistivity data measured on anywhere of the dam. In this study, we analyse the influence from 3D effects created by specific dam geometry through the 3D finite element modeling technique. We compared 3D effects when resistivity surveys are carried out on the upstream slope, left edge of the crest, center of the crest, right edge of the crest and downstream slope. We ensure that 3D effect is greatly different according to the location of the survey line and data obtained on the downstream slope are most greatly influenced by 3D dam geometry. Also, resistivity data are more influenced by the electrical resistivity of materials constituting reservoir than 3D effects due to specific dam geometry. Furthermore, using resistivity data synthesized with 3D modeling program for an embankment dam model with leakage zone, we analyse the possibility of leakages detection from 2D resistivity surveys performed along the embankment dam.

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

Development of Waterproofing Method to Improve the Leakage Resistance and Maintenance of Underground Structures (구조물 누수 저항 및 유지관리 향상을 위한 방수공법 개발)

  • Kim, Eun-seok;Park, Hyun-Jung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, various maintenance materials and construction methods have been developed to secure the sustainable performance of structures. However, waterproofing of underground structures where groundwater infiltration is present is very difficult. In particular, the location of underground structures such as subways is very deep, and it is difficult to apply waterproof materials and construction methods in the case of structures accompanied by vibration. Therefore, we intend to study materials and methods for waterproofing leakage resistance in special environments such as underground structures.

  • PDF

Electrical resistivity survey for evaluation of reinforced region by cement grouting in dike (전기비저항 수직탐사를 이용한 저수지 그라우팅 구간 평가)

  • 송성호;장의웅;김진호;김진성;김진춘
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.63-73
    • /
    • 2002
  • To evaluate reinforced region of dike by cement grouting, we investigated both the electrical resistivity and the strength of cement grout having various water-cement ratio with curing time. These investigation results showed that the electric conductivity of grout is much higher than that of water and that the apparent resistivity of grouted region is much lower than that of unoccupied region by grout. It was founded that electrical resistivity survey might be quite effective to detect grout region in dike. As the results of electrical resistivity sounding at three dikes, apparent resistivities after grouting showed several tens to several hundreds of ohm-m which were lower than those of pre-grouting and showed stabilizing trend with curing time. From these results, we could estimate that this behavior of apparent resistivity is due to increasing strength with curing time.