• Title/Summary/Keyword: 누설 진단

Search Result 91, Processing Time 0.032 seconds

An Experimental Study on the Dryness Judgement Criterion for Water-cooled Generator Stator Windings (수냉각 발전기 고정자의 권선 내부 건조 판정 기준 설정에 관한 실험적 연구)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.137-143
    • /
    • 2010
  • Complete dryness inside the stator is a necessary and sufficient condition for the leak test. Microcracks caused by high cycle fatigue due to operation are generated in stator windings, and they are interrupted by water molecules during the leak test. For this reason, during leak test, the wrong value is indicated when there are no leaks in stator windings. Generator manufacturers presents unique dryness judgment criteria for the leak test, but there is no actual criterion that accurately indicates the dryness point for the leak test. The reason is because stator winding has a complex structure and the absence of effective dryness equipment in power plants. This paper proposes a dryness judgment criterion to evaluate if inside the stator winding is dried completely and presents experimental results.

Guideline for Field Partial Discharge measurement of Underground Transmission Level XLPE Cable (지중송전 XLPE케이블 활선상태 PD 측정기술 향상을 위한 가이드라인 제시)

  • Park, Jin-Woo;Choi, Kyung-Kyu;Lee, Joen-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.141-142
    • /
    • 2008
  • 국내 지중송전선로는 주로 XLPE케이블과 OF케이블로 구성된다. 1971년 154kV급 OF 케이블이 최초로 한전에 의해 상용운전에 들어간 후 XLPE 케이블 지중선로가 1983년부터 병용운전 되고 있으며 OF케이블의 경우 절연유의 사용으로 인한 화재의 위험과 환경오염 문제 등으로 인하여 점진적으로 XLPE케이블로 대체되는 추세에 있다. 하지만 내전압 시험, 절연저항이나 누설전류 측정, $tan{\delta}$ 측정 등으로 진단이 가능했던 OF케이블과는 달리 XLPE케이블의 경우 종래의 시험을 통한 진단은 한계가 있고 부분방전을 통한 진단이 가장 효율적인 진단방법으로 제시되어 국내외 XLPE케이블의 진단을 위해 운영되고 있으며 보다 정확한 PD측정을 위한 연구가 계속 진행되고 있다. 지난 10년여간의 국내외 연구결과 XLPE케이블에 대한 PD 측정기술의 정확성은 상당히 향상되었고 그 결과물로서 수많은 폭정 장비와 기법이 개발되어 오늘날 널리 보급되고 있다. 하지만 여전히 측정된 Data에 대한 해석은 일부 전문가들에게 조차 복잡하고 어려운 일로 남아 있다. 자칫 그릇된 해석은 향후 큰 사고로 이어질 수 있으므로 선로 운영자의 입장에서는 측정결과의 신뢰성에 민감할 수밖에 없다.

  • PDF

Magnetic Flux Leakage based Damage Quantification of Steel Bar (누설자속기법을 이용한 강봉의 손상 정량화 기법)

  • Park, Jooyoung;Kim, Ju-Won;Yu, Byoungjoon;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • In this paper, a magnetic flux leakage(MFL) based steel bar damage detection was first researched to quantify the signals from damages on the wire rope. Though many researches inspecting damages using a MFL method was proceeded until the present, the researches are at the level that diagnose whether damages are or not. This has limitation to take measures in accordance with the damage level. Thus, a MFL inspection system was modeled using a finite element analysis(FEM) program dealing with electromagnetism problems, and a steel bar specimen was adopted as a ferromagnetic object. Then, an experimental study was also carried out to verify the simulation results with a steel bar which has same damage conditions as the simulation. The MFL signals was nearly not affected by the increase of the inspection velocity, and the magnitudes of the signals are not identical according to the change of the defect width even the defects have same depth. On the basis of the analysis, the signal properties from the damages were extracted to classify the type of damages, and it could be confirmed that classification of damages using extracted signal properties is feasible.

Leak Detection and Real-time Monitoring System for Boiler Tube (보일러 튜브 누설 검출 및 실시간 감시 시스템)

  • Choi, Min-Gi;Kim, Jae-Young;Jeong, In-kyu;Kim, Young-Hun;Kim, Yu-Hyun;Kim, Jong-Myon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.67-68
    • /
    • 2018
  • 본 논문에서는 다수의 음향방출 센서로부터 취득한 원 데이터를 관리하고 보일러 튜브에 대한 상태를 실시간으로 진단하고 모니터링을 할 수 있는 네트워크 기반의 보일러 튜브 모니터링 시스템을 제안한다. 본 시스템을 화력발전소 보일러 튜브에 설치한다면 보일러의 불시정지를 예방하는데 효과적일 것으로 기대된다.

  • PDF

A Study on the Packing Friction Estimation of Power-Operated Valves in Nuclear Power Plants (원전 동력구동 밸브 패킹 마찰력 예측에 관한 연구)

  • Ryu, Dong Hwa;Lee, Young Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1053-1060
    • /
    • 2013
  • The purpose of this study is to estimate the packing friction of power-operated valve in nuclear power plants. The roll of packing in valve is preventing leakage through stem. Packing friction is highly depend on gland nut tightness which means higher reliability in sealing is lower operability. For the estimation of friction, we used statistical analysis and experimental analysis. In experimental approach, we have performed packing fY test and applied it to valve field test. In statistical approach, we have used 10 years DB of safety-related valve in nuclear power plant and analyzed packing friction based on confidence interval of sample. The comparison of two results shows that statistical analysis for packing friction are more accurate than fY analysis even though both approach have error compared to measured value but we confirmed that statistical approach is proper way to estimate packing friction.

Development and Application of IoT-based Contactless Ultraosonic System (IoT 기반 비접촉 초음파 측정 시스템 개발 및 적용)

  • Kim, Jihwan;Hong, Jinyoung;Kim, Rrulri;Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.70-79
    • /
    • 2020
  • The main objective of this research to develop an IoT based wireless contactless ultrasonic system (ICUS) and its application to concrete structure. The developed system consists of 16 mems, 2Mhz digitizer, amplifying circuit, FPGA, and wifi module, enabling to measure leaky surface waves from concrete specimens without physical coupling process and wires. Multi-channel analysis is performed to improve the accuracy of data analysis, and the velocity of leaky surface waves and acoustics are derived. Field inspection of railroad concrete sleepers is conducted to evaluate the performance of the system and to compare the results with conventional ultrasonic pulse velocity (UPV). As a result of the field inspection, UPV was limited to evaluate damages. This is because crack pattern of railroad sleepers is parallel to ultrasonic ray path and accessibility of the railroad at the field is disadvantageous to contact-based UPV. On the other hand, ICUS possibly detect the damages as reduction of dynamic modulus by up to 59% compared to non-damaged specimen.

Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog (SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석)

  • 박재준;양태규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.500-504
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and .am) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonir waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis (밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구)

  • Lee, Sang-Guk;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF

Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring (Multi-measuring기법을 이용한 원전 제어밸브의 누설진단)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Bong-Ho;Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

Acoustic Emission based early fault detection and diagnosis method for pipeline (음향방출 기반 배관 조기 결함 검출 및 진단 방법)

  • Kim, Jaeyoung;Jeong, Inkyu;Kim, Jongmyon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.571-578
    • /
    • 2018
  • The deteriorated pipline often causes the unexpected leakage and crack. Negligence and late maintenance leads the enormous damage for gas and water resource. This paper proposes early fault detection and diagnosis algorithm for pipeline using acoustic emission (AE) signals. Early fault detection method for pipeline compares the frequency amplitude of the spectrum to that of the spectrum in normal condition. Larger amplitude of the spectrum indicates abnormal condition. Early fault diagnosis algorithm uses support vector machines (SVM), which is trained for normal and abnormal conditions to diagnose the measured AE signal from the target pipeline. In the experiment, a pipeline testbed is constructed similarly to real industrial pipeline. Normal, 5mm cracked, 10mm holed pipelines are installed and tested in this study. The proposed fault detection and diagnosis technique is validated as an efficient approach to detect early faulty condition of pipeline.