• Title/Summary/Keyword: 누설 전류

Search Result 1,031, Processing Time 0.038 seconds

Development of the Leakage Current Detection Module for a Concent (콘센트용 누전감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.447-452
    • /
    • 2013
  • In this paper, the leakage current detection and auto shut-off module for a concent has been developed. Existing leakage current detection modules are detecting resistive leakage current, using a resistive leakage current detection chip but the proposed leakage current detection module separates and detects resistive leakage current in the synthesis leakage current by only programming in a power processor MCU(MSP430). The module implemented by proposed method has early detection and auto shut-off feature at more than resistive leakage current 5mA, and has the advantage of easily adjusting resistive leakage current less or more than 5mA, because of resistive leakage current detection function being implemented by a program in MCU.

Improvement of Leakage current In PZT Thin Films I -Analysis of Leakage Current Mechanism and Effects of Substrate Protection Layer in PZT Thin Films- (PZT 박막의 누설전류 개선에 관한 연구 I -PZT 박막의 누설전류 기구 분석 및 기판 보호층의 효과-)

  • 마재평
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.1
    • /
    • pp.101-110
    • /
    • 1998
  • 큰 누설전류를 개선하고 누설전류 기구를 해석하기 위해 Pt/Ti/ SiO2/Si 기판상에서 2단계 sputtering 하여 PZT박막을 형성시켰다. 상온층과 perovskite의 두층으로 이루어진 PZT박막은 누설전류가 개선되었다. 특히 20nm의 상온층을 포함하는 PZT 박막은 유전상수 와 누설전류 특성이 모두 탁월한 것으로 나타났다. 이와 같은 조건에서 PZT 박막의 누설전 류 기구는 bulk 지배하는 기구로 바뀌었다.

$Si0_2$ Passivation Effects on the Leakage Current in Dual-Gate AIGaN/GaN High-Electron-Mobility Transistors (이중 게이트 AIGaN/GaN 고 전자 이동도 트랜지스터의 누설 전류 메커니즘과 $Si0_2$ 패시베이션 효과 분석)

  • Lim, Ji-Yong;Ha, Min-Woo;Choi, Young-Hwan;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.65-66
    • /
    • 2006
  • AIGaN/GaN 고전자 이동도 트랜지스터 (High Electron Mobility Transistors, HEMTs)는 와이드 밴드-갭과 높은 항복 전계 및 우수한 채널 특성으로 인해 마이크로파 응용분야와 전력용 반도체에서 각광받고 있다. 최근, 전력 응용분야에서 요구되는 높은 항복 전압과 출력, 우수한 주파수 특성을 획득하기 인해 이중 게이트 AIGaN/GaN HEHTs에 관한 연구가 발표되고 있다. 본 논문에서는 AIGaN/GaN HEMTs에 이중 게이트를 적용하여, 두 개의 게이트와 드레인, 소스의 누설 전류를 각각 측정하여 이중 게이트 AIGaN/GaN HEMTS의 누설 전류 메커니즘을 분석하였다. 또한 제안된 소자의 $SiO_2$ 패시베이션 전 후의 누설 전류 특성을 비교하였다. $SiO_2 $ 패시베이션되지 않은 소자의 누설 전류는 드레인, 소스와 추가 게이트로부터 주 게이트로 흐른 반면, 패시베이션 된 소자 누설 전류는 드레인으로부터 주 게이트 방향의 누설 전류만 존재하였다. $SiO_2$ 패시베이션 된 소자의 누설 전류는 (87.31 nA ) 패시베이션 되지 않은 소자의 누설 전류 ( $8.54{\mu}A$ )에 비해 의게 감소하였다.

  • PDF

The analysis of leakage current of InGaAsP/InP PBH-LD fabricated by LPE (LPE 방법으로 제작된 InGaAsP/InP PBH-LD의 누설전류해석)

  • 최미숙;김정호;홍창희
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.481-485
    • /
    • 2002
  • In this study, we fabricated the PBH-LD by meltback method using the LPE. The PBH-LDs are analyzed the leakage current that flows through leakage current path like the p-n diode and p-n-p-n current blocking layer. We observed the variation of threshold current with the leakage width $W_{ι}$. As a consequence, we confirmed that the threshold current became low in the decrease of the leakage width and in the increase of the ratio of specific resistivity of leakage region to active region. We also compared between the calculated threshold current in the absence of leakage region and the measured threshold current in the device. As a result, the ratio of specific resistivity was about 0.5 in the measured LDs, which have the width of a active layer of 1.4${\mu}{\textrm}{m}$ and leakage width of 0.6${\mu}{\textrm}{m}$.

  • PDF

A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구)

  • Kim, Ji-Myung;Tae, Dong-Hyun;Lee, Il-Moo;Lim, Geon-Pyo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.810-818
    • /
    • 2021
  • A leakage current of ESS is classified mainly by the occurrence from a PCS(Power Conditioning System) section and an unbalanced grid current. The reason for the leakage current from the PCS section is a voltage change by IGBT (Insulated Gate Bipolar Transistor) switching and stray capacitance between the IGBT and heatsink. The leakage current caused by the grid unbalanced current flows to the ESS through the neutral line of grid-connected transformer for the ESS with a three limb iron type of Yg-wire connection. This paper proposes a mechanism for the occurrence of leakage current caused by stray capacitance, which is calculated using the heatsink formula, from the aspect of the PCS section and grid unbalance current. Based on the proposed mechanisms, this study presents the modeling of the leakage current occurrence using PSCAD/EMTDC S/W and evaluates the characteristics of leakage currents from the PCS section and grid unbalanced current. From the simulation result, the leakage current has a large influence on the battery side by confirming that the leakage current from the PCS is increased from 7[mA] to 34[mA], and the leakage current from an unbalanced load to battery housing is increased from 3.96[mA] to 10.76[mA] according to the resistance of the housings and the magnitude of the ground resistance.

WS시리즈 누설전류표시부 차단기

  • KOREA ELECTRIC ASSOCIATION KOREA ELECTRIC ASSOCIATION
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.307
    • /
    • pp.68-73
    • /
    • 2002
  • 감전보호$\cdot$누전화재보호로서 누전차단기가 일반적으로 사용되고 있는데 이 누전차단기가 누전으로 트립되었을 경우 (1) 누전트립이 재현되지 않는다. (2) 누설전류치가 고조파의 영향 때문에 측정이 곤란하다는 등의 이유로 원인조사가 어려운 경우가 많다. 그래서 누전차단기의 동작원인조사를 지원하는 기기로서 WS시리즈의 노퓨즈차단기 및 누전차단기에 각종 누설전류치의 액정표시유닛을 탑재한 $''$누설전류표시부 노퓨즈차단기$\cdot$누전차단기$''$를 제품화하였다. 이에 의하여 전로에 영상변류기(ZCT)와 계측기 등을 설치하지 않고 전로의 절연열화상태나 누전사고 상황을 간단하게 파악할 수가 있다. 또 액정표시유닛의 제어전원은 차단기 내부에 포함하고 있기 때문에 특별배선작업은 불필요하다. 이 제어전원은 차단기가 오프상태 또는 트립상태에서는 끊어지나 내부에 전기이중충 콘덴서를 내장하고 있기 때문에 각종 누설전류 정보를 표시할 수가 있다(정전보상시간 100시간). 주요특징은 다음과 같다. (1)각종 누설전류의 계측과 표시(현재치, 최대치, 이동평균치, 이동평균의 최대치, 각 최대치의 발생경과시간) (2) 누전경보의 설정 감도를 세분화하여 설정가능 또한 접점경보출력 표준탑재 (3) 누전트립 발생시의 누전사고전류치 및 누전사고 발생으로부터의 경과시간 표시(누전차단기만) (4) 미쓰비시전기 누전차단기의 액티브필터와 같은 특성의 필터를 내장하고 있으며 누전차단기의 동작특성에 맞는 누설전류치 표시가능 (5) 누전경보만으로 누전트립 동작을 하지 않는 누설전류표시부 노퓨즈차단기 라인업

  • PDF

Development of DC Leakage Disconnector for Solar Power Generation System (태양광 발전용 단상 30kW급 직류누전차단기 개발)

  • Han, Hoo Sek;Cho, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1567-1568
    • /
    • 2015
  • 태양광 발전시스템에서 발생되는 누설전류에 인하여 누전화재와 인체감전 등의 전기재해를 방지하기 위해서 직류누전차단기를 개발하였다. 직류누설전류를 측정할 수 있는 센서를 개발하여 (+)전선로와 (-)전선로에 흐르는 누설전류를 각각 검출하는 방법을 제안하였다. 제안된 방법과 개발된 센서를 이용하여 시작품을 제작하고 센서에 대한 감도전류 특성시험을 수행하였다. 또한 인버터가 포함되어 있는 태양광 발전시스템에 적용하여 실제 나타나는 직류누설전류를 측정하는 시험을 수행하였다. 그 결과 직류누설전류센서의 정확성을 확인하였으며, 전선로에 흐르는 직류 및 교류성분의 누설전류를 ${\pm}5%$ 범위 내에서 측정함을 확인하였다. 개발된 센서를 적용한 태양광 발전용 직류누전차단기를 제작하였다.

  • PDF

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.

Aging Detection of Distribution Lightning Arresters by Analysis of Leakage Current (누설전류분석에 의한 가공배전선로용 피뢰기의 성능진단)

  • Chu, Chul-Min;Park, Chul-Bae;Lee, Byung-Sung;Kim, Gi-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2046-2047
    • /
    • 2008
  • 본 논문에서는 가공 배전선로에 사용되고 있는 피뢰기의 상태 진단을 위한 누설전류 분석기법에 대해 기술하였다. 현장에서 다양한 환경 스트레스를 받고 있는 피뢰기는 점차 열화가 진행되어 선로 고장의 원인이 되므로 이를 사전에 검출하여 고장을 예방하는 것이 중요하다. 피뢰기 이상을 효과적으로 검출하는 방법의 하나로 사용되고 있는 누설전류 측정방법에 대해 평가하였다. 피뢰기 누설전류는 측정 환경에 영향을 받을 수 있기 때문에 현장 측정한 결과와 실험실에서 측정한 결과를 비교하여 분석하여 환경영향을 보정하여 판단하는 방법을 고려하였다. 또한 온도에 따른 누설전류 값의 변화를 분석하여 누설전류에 의한 피뢰기 상태 판단 근거를 마련하였다. 이를 위해 현장에서 설치 운용되고 있는 피뢰기를 지역별로 고르게 발취하여 측정 분석하였다.

  • PDF