Development of the Leakage Current Detection Module for a Concent (콘센트용 누전감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.447-452
    • /
    • 2013
  • In this paper, the leakage current detection and auto shut-off module for a concent has been developed. Existing leakage current detection modules are detecting resistive leakage current, using a resistive leakage current detection chip but the proposed leakage current detection module separates and detects resistive leakage current in the synthesis leakage current by only programming in a power processor MCU(MSP430). The module implemented by proposed method has early detection and auto shut-off feature at more than resistive leakage current 5mA, and has the advantage of easily adjusting resistive leakage current less or more than 5mA, because of resistive leakage current detection function being implemented by a program in MCU.

Improvement of Leakage current In PZT Thin Films I -Analysis of Leakage Current Mechanism and Effects of Substrate Protection Layer in PZT Thin Films- (PZT 박막의 누설전류 개선에 관한 연구 I -PZT 박막의 누설전류 기구 분석 및 기판 보호층의 효과-)

  • 마재평
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.1
    • /
    • pp.101-110
    • /
    • 1998
  • 큰 누설전류를 개선하고 누설전류 기구를 해석하기 위해 Pt/Ti/ SiO2/Si 기판상에서 2단계 sputtering 하여 PZT박막을 형성시켰다. 상온층과 perovskite의 두층으로 이루어진 PZT박막은 누설전류가 개선되었다. 특히 20nm의 상온층을 포함하는 PZT 박막은 유전상수 와 누설전류 특성이 모두 탁월한 것으로 나타났다. 이와 같은 조건에서 PZT 박막의 누설전 류 기구는 bulk 지배하는 기구로 바뀌었다.

A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구)

  • Kim, Ji-Myung;Tae, Dong-Hyun;Lee, Il-Moo;Lim, Geon-Pyo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.810-818
    • /
    • 2021
  • A leakage current of ESS is classified mainly by the occurrence from a PCS(Power Conditioning System) section and an unbalanced grid current. The reason for the leakage current from the PCS section is a voltage change by IGBT (Insulated Gate Bipolar Transistor) switching and stray capacitance between the IGBT and heatsink. The leakage current caused by the grid unbalanced current flows to the ESS through the neutral line of grid-connected transformer for the ESS with a three limb iron type of Yg-wire connection. This paper proposes a mechanism for the occurrence of leakage current caused by stray capacitance, which is calculated using the heatsink formula, from the aspect of the PCS section and grid unbalance current. Based on the proposed mechanisms, this study presents the modeling of the leakage current occurrence using PSCAD/EMTDC S/W and evaluates the characteristics of leakage currents from the PCS section and grid unbalanced current. From the simulation result, the leakage current has a large influence on the battery side by confirming that the leakage current from the PCS is increased from 7[mA] to 34[mA], and the leakage current from an unbalanced load to battery housing is increased from 3.96[mA] to 10.76[mA] according to the resistance of the housings and the magnitude of the ground resistance.

Development of residual current detector for protecting human and equipment of TN grounding systems in DC power distribution systems (TN접지방식 직류배전에서의 인체 및 설비 보호를 위한 누설전류 검출기)

  • Lee, Won-Ki;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.64-65
    • /
    • 2014
  • 신재생에너지원의 급속한 보급, 고신뢰 및 고효율 전원망에 대한 고객의 요구, 디지털부하의 급증 등 기술적 사회적 환경의 변화에 따라 직류배전망에 대한 관심이 높아지고 있다. 이에 따라 직류배전망의 안전성에 대한 문제도 지속적으로 제기되고 있다. 특히 지락, 단락사고, 절연고장, 낙뢰, 아크, 전식 등으로부터 인체 감전과 기기의 소손, 정지 또는 오동작이 발생될 수 있으며 이로 인해 심각한 문제를 야기될 수 있다. 국제표준 IEC 60364에서는 전기설비에 따른 접지시스템을 TT, TN 및 IT접지의 3가지로 분류하고 있다. TN접지방식은 전원선과 설비외함의 노출 도전부를 보호도체를 사용하여 공통으로 접지하는 계통을 말한다. 따라서, 전원선이 외함에 접촉되거나 인체의 감전에 의한 누전사고가 발생하였을 때 전원선 전체를 통하여 흐르는 전류의 차이를 검출함으로서 사고전류의 검출이 즉각 이루어 질 수 있다. 교류계통에서는 영상전류검출기에 의하여 누설전류의 검출이 가능하지만 직류계통에서는 영상전류검출기를 사용할 수 없으므로 새로운 방식의 누전검출장치의 개발이 요구된다. 또한 감전 사고는 인체의 사고와 설비의 사고 두 가지로 구별되며, 효율적인 전력운영과 안전을 위하여 두가지 사고에 대해 통합적으로 구분 동작이 가능한 누설전류 검출기 개발이 요구된다. 본 연구에서는 TN접지계통에서 직류누설전류 검출이 가능한 홀 센서(HCT)를 사용하여 인체 및 설비의 누설전류 패턴에 따라 구분 동작이 가능한 직류용 누설전류 검출기 개발에 관한 연구를 수행하였다.

  • PDF

A Study on the Low Level Leakage Currents of Silicon Oxides (실리콘 산화막의 저레벨 누설전류에 관한 연구)

  • 강창수;김동진
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.29-32
    • /
    • 1998
  • The low level leakage currents in silicon oxides were investigated. The low level leakage currents were composed of a transient component and a do component. The transient component was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The do component was caused by trap assisted tunneling completely through the oxide. The low level leakage current was proportional to the number of traps generated in the oxides. The low level leakage current may be a trap charging and discharging current. The low level leakage current will affect data retention in EEPROM.

  • PDF

Characteristic Test on the Leakage Current of Transmission Insulators (송전용 애자의 누설전류 특성에 관한 연구)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il;Kim, Tea-Young;Sin, Tea-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.479-481
    • /
    • 2003
  • 송전용 애자의 누설전류 측정을 위한 실증 시험장치로 애자의 누설전류 특성에 관한 조사를 하였다. 자기, 유리 및 폴리머 애자에 선간전압 154 [kV]의 전압을 인가하여 바닷가 주위에서 누설전류 파형과 일일 누설전류 및 외부 환경적 parameter들과의 상관 관계에 대하여 고찰하였다. 그 결과 자기 및 유리애자는 습기가 높은 새벽과 밤에는 높은 누설전류가 나왔으며 폴리머 애자는 hydrophobicity의 특성 때문에 환경적 변화에 크게 영향을 받지 않았다.

  • PDF

Analysis of Leakage Current by Common-Mode Voltage in Single-Phase Converter/Three-Phase Inverter System (단상 컨버터/3상 인버터 시스템에서 공통모드 전압에 의한 누설전류 분석)

  • Kim, Won-Jae;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.386-387
    • /
    • 2019
  • 본 논문에서는 단상 컨버터/3상 인버터 시스템에서 공통모드에 의한 누설전류를 분석하였다. 컨버터/인버터 시스템의 공통모드 전압은 시스템에 존재하는 기생 임피던스를 충방전함으로써 수 A의 누설전류를 발생시킨다. 이에 본 논문에서는 단상 컨버터/3상 인버터 시스템에서 컨버터 입력 측 변압기와 전동기의 기생 임피던스를 고려하여 누설전류를 분석하였으며, 누설전류를 감소하기 위해 공통모드 전압 저감하는 방법을 제안한다. 모의실험을 통하여 제안된 기법에 의한 누설전류의 저감효과를 확인하였다.

  • PDF

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

Aging Detection of Distribution Lightning Arresters by Analysis of Leakage Current (누설전류분석에 의한 가공배전선로용 피뢰기의 성능진단)

  • Chu, Chul-Min;Park, Chul-Bae;Lee, Byung-Sung;Kim, Gi-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2046-2047
    • /
    • 2008
  • 본 논문에서는 가공 배전선로에 사용되고 있는 피뢰기의 상태 진단을 위한 누설전류 분석기법에 대해 기술하였다. 현장에서 다양한 환경 스트레스를 받고 있는 피뢰기는 점차 열화가 진행되어 선로 고장의 원인이 되므로 이를 사전에 검출하여 고장을 예방하는 것이 중요하다. 피뢰기 이상을 효과적으로 검출하는 방법의 하나로 사용되고 있는 누설전류 측정방법에 대해 평가하였다. 피뢰기 누설전류는 측정 환경에 영향을 받을 수 있기 때문에 현장 측정한 결과와 실험실에서 측정한 결과를 비교하여 분석하여 환경영향을 보정하여 판단하는 방법을 고려하였다. 또한 온도에 따른 누설전류 값의 변화를 분석하여 누설전류에 의한 피뢰기 상태 판단 근거를 마련하였다. 이를 위해 현장에서 설치 운용되고 있는 피뢰기를 지역별로 고르게 발취하여 측정 분석하였다.

  • PDF

Low Leakage Input Vector Searching Techniques for Logic Circuits at Standby States (대기상태인 논리 회로에서의 누설전류 최소화 입력 탐색 방법)

  • Lee, Sung-Chul;Shin, Hyun-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.53-60
    • /
    • 2009
  • Due to increased integration density and reduced threshold voltages, leakage current reduction becomes important in the semiconductor IC design for low power consumption. In a combinational logic circuit, the leakage current in the standby state depends on the values of the input. In this research, we developed a new input vector control method to minimize the leakage power. A new efficient algorithm is developed to find the minimal leakage vector. It can reduce the leakage current by 15.7% from the average leakage current and by 6.7% from the results of simulated evolution method during standby or idle states for a set of benchmark circuits. The minimal leakage input vector, with idle input signal, can also reduce the leakage current by 6.8% from the average leakage current and by 3.2% from the results of simulated evolution method for sequential circuits.