• Title/Summary/Keyword: 농도 측정

Search Result 10,146, Processing Time 0.051 seconds

Inhibitory effect of Koreinsis chinensis leaves extract on proinflammatory responses in lipopolysaccharide-induced Raw 264.7 cells (Lipopolysaccharide로 유도된 Raw 264.7 cell에서 잣 잎(Koreinsis chinensis L.) 추출물의 Pro-inflammatory 억제 효과)

  • Cho, Young-Je
    • Journal of Applied Biological Chemistry
    • /
    • v.60 no.3
    • /
    • pp.191-198
    • /
    • 2017
  • Hyaluronidase inhibitory activity as inflammatory factor of Koreinsis chinensis leaf ethanol extract was showed higher inhibitory activity than water extract. 29.5% inhibitory activity was shown at concentration of $200{\mu}g/mL$ phenolics. Lipopolysaccharide (LPS)-stimulated Raw 264.7 cells were treated with different concentrations ($5-25{\mu}g/mL$) of Koreinsis chinensis leaf extract and the amount of nitric oxide (NO) was determined; LPS-treated cells produced 3 times more NO than non-LPS treated cells. Moreover, the NO production in cells treated with Koreinsis chinensis leaf extract showed inhibitory effect in a concentration-dependent manner. Due to the stimulant-induced NO production is regulated by the inducible nitric oxide synthase (iNOS), we determined the iNOS protein level to elucidate the mechanism by which the NO production was inhibited. It was reduced by 40% with a Koreinsis chinensis leaf extract concentration of $25{\mu}g/mL$ and identified iNOS inhibition in dose-dependent manner. The prostaglandin $E_2$ production in cells treated with Koreinsis chinensis leaf extract was reduced by 26.2% at concentration of $25{\mu}g/mL$. The protein expression of cyclooxygenase-2 in LPS-treated Raw 264.7 cells was inhibited by 64% at $25{\mu}g/mL$ of Koreinsis chinensis leaf extract. Koreinsis chinensis leaf extract had a concentration-dependent inhibitory effect on the production of tumor necrosis factor-${\alpha}$ and interleukin-6 as pro-inflammatory cytokine in LPS-treated Raw 264.7 cells at $25{\mu}g/mL$ of Koreinsis chinensis leaf extract. Their levels were decreased by 61.7 and 62% respectively.

Characteristics of Voltammetric Urea Sensors Based on Poly(3-methylthiophene) film (Poly(3-methylthiophene)막 위에 urease를 고정화 한 voltammetric biosensor의 특성)

  • Park, Sung-Ho;Park, Buh-Hun;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1766-1768
    • /
    • 2000
  • 신장병 진단의 척도로 요소의 농도는 매우 중요하다. 요소의 농도를 측정하기 위한 센서개발이 본 연구의 목적이다. 기존의 Potentiometry법은 Nernst식이 적용된다는 가정하에 감도를 측정했다. 실험결과 전극상에서 우레아제의 요소 가수분해 반응은 Nernst식을 적용할 수 없는 비가역적인 반응으로 판단되어 센서의 감도 측정을 Linear sweep Voltammetry(LSV)법을 이용하였다. Voltammetry법은 가역적이든 비가역적이든 관계없이 Cottrell 식에 의한 전류와 농도의 직선관계로부터 감도를 측정할 수 있다는 장점이 있다. 센서 전극의 표면은 SEM으로 분석하였고, LSV 법으로 측정한 센서의 감도는 $34{\mu}A$/decade 였다.

  • PDF

Oxidative Stress in the Cell and Antioxidant Activity of Kalopanax Pictus Extracts (음나무 추출물의 세포 내 산화 스트레스와 항산화 활성)

  • Kim, Sea-Hyun;Park, Youngki;Jang, Yong-Seok;Han, Jingyu;Chung, Hun-Gwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.126-134
    • /
    • 2007
  • This study reviewed the application of an extract from Kalopanax pictus stem bark and root bark as natural antioxidants. To investigate the effect on cell toxic level against transformed mouse fibroblast L929 in formula added with various extracts from Kalopanax pictus stem bark and root bark, this experiment was carried out by in vitro cytotoxicity method. Using DCFA-DA method, oxidative stress in cell was measured with other antioxidant activity methods including DPPH assay and NBT assay. Active oxygen inhibition rate for root bark insoluble hot water extracts showed the highest with 57.9% for 15 min treatment. In DPPH and NBT test, antioxidant activities of methanol extract from stem bark and insoluble hot water extract from stem bark were 96% (at 0.1%) and 95% (at 0.5%), respectively.

Analysis of transverse mixing in rivers by tracing of continuously injected pollutants (연속주입 오염물 추적을 통한 하천 횡혼합 해석)

  • Seo, Il Won;Jung, Sung Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.193-193
    • /
    • 2015
  • 오염원과 취수원이 인접한 위치에 존재하는 국내 하천 같은 경우 취수 시설의 안전한 관리를 위하여 오염물의 2차원 혼합 거동에 대한 연구가 필요하다. 하천에서의 오염물 혼합 거동을 분석하기 위하여 일반적으로 농도와 분산 정보 수집을 위한 추적자 실험을 수행해왔다. 기존에 수행된 추적자 실험들은 형광염료, 방사선 물질, 고형 물질 등과 같은 추적자를 인위적으로 주입하여 사용하였다. 그러나 수온, 전기전도도(electrical conductivity), 이온화 물질 등과 같은 자연 추적자(natural tracers)를 이용하는 추적자 실험은 인공추적자 물질을 대체할 수 있는 방안으로서, 기존 추적자 실험과 비교하여 경제적, 환경적인 효과와 하폭이 넓은 중규모 이상의 하천에서도 수행할 수 있다는 장점을 가지고 있다. 본 연구에서는 진천천과 금호강이 합류하는 낙동강 중류 구간에서 횡혼합 연구를 위하여 전기 전도도 추적 실험을 수행하였다. 강정고령보 직하류에서 낙동강 좌안쪽에서 합류하는 금호강과 진천천의 경우 인근 공업단지와 하폐수처리장으로부터 많은 비점오염원과 점오염원이 유입된다. 두곳의 지류에서 모두 높게 측정되었던 전기전도도를 자연 추적자로 선택하였다. 지류의 경우 전기전도도를 측정할 수 있는 센서를 측정 지점에 설치하여 측정하였으며, 본류인 낙동강의 경우 정해진 측선을 따라 센서가 고정된 보트를 이동하며 데이터를 취득하였다. 지류인 금호강과 진천천의 경우, 합류 전 전기전도도의 농도의 횡분포는 균일한 분포를 나타냈으며 농도의 평균값은 합류 전 낙동강 본류의 기저농도 보다 더 높은 값을 나타내었다. 지류 합류 이후의 낙동강 본류에서는 지류로부터 유입된 오염물질로 인하여 횡방향으로 불균등한 전기전도도 농도 분포를 나타내었으며 오염물질이 점점 하류 쪽으로 이동하면서, 횡방향 농도경사의 크기가 줄어들었다. 유관모멘트법을 농도곡선에 적용하여 횡방향 분산계수를 산정하였다. 산정된 횡분산계수의 값은 Rutherford (1994)가 제안한 분산계수의 범위에 포함되는 것으로 나타났다.

  • PDF

Characteristics of Indoor PM2.5 and the effect of air purifier and ventilation system on Indoor PM2.5 in the Knowledge Industrial Center office during the atmospheric PM2.5 warning (초미세먼지 주의보 시 지식산업센터 사무실의 실내 초미세먼지 농도 특성과 공기청정기와 환기장치의 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.16 no.3
    • /
    • pp.65-72
    • /
    • 2020
  • In this study, the indoor fine dust concentration in an office of the Korea Knowledge Industry Center was measured for about 80 hours when the concentration of atmospheric PM2.5 was very high. The effect of the operation of the air cleaner and the forced ventilation system on the indoor PM2.5 was investigated, and the particle size distribution of the indoor and outdoor particles was analyzed. When forced ventilator and air purifiers were partially used, the indoor PM2.5 concentrations were maintained between 27.7 ㎍/㎥ and 32.9 ㎍/㎥ when the atmospheric PM2.5 was 127.7 ㎍/㎥ to 141.6 ㎍/㎥ during working hours. It is more effective to operate the air purifier without operating the forced ventilation system when the concentration of the PM2.5 is high since the PM2.5 penetrating the installed filter is continuously introduced indoor from the outside.

Effects of Baicalein on Picryl Chloride-induced Contact Dermatitis in BALB/c Mice (Baicalein의 BALB/c Mice에서의 접촉성 피부알레르기 예방효과)

  • Kim, Soo-Hyun;Kim, Hyeong-Jin;Jung, Ji-Youn
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.2
    • /
    • pp.160-165
    • /
    • 2009
  • Contact dermatitis is induced by allergy response from a lot of chemical substances brought on by environmental contamination. In this study, we investigated allergy prevention effect of baicalein which is Scutellaria radix extract. Scutellaria radix is the dried roots of Scutellaria baicalensis Georgi (Labiatae). It has been used in oriental traditional medicine for treatment of fever, diarrhea and inflammation. We have induced allergy by PCL after oral administration of 0 mg/kg, 50 mg/kg or 100 mg/kg baicalein dose for 8 times during 8 days in BALB/c mice and measured ear thickness, IgE level, histamine level, mast cell number and histopathological changes. The ear thickness of the 100 mg/kg baicalein group was thinner than that of the 0 mg/kg baicalein group. IgE level and histamine level of the 100 mg/kg baicalein group were lower than those of 0 mg/kg baicalein group. The number of mast cells of 0 mg/kg baicalein group more than that of 100 mg/kg baicalein group in the ear tissue. In addition, intradermal edema with prominent inflammatory cell infiltration was observed at 0 mg/kg baicalein group more than 100 mg/kg baicalein group in the ear tissue. These results suggest that baicalein has allergy prevention effect in BALB/c mice.

2021 Sediment discharge survey and analysis of characteristics (2021년 유사량 조사 및 특성분석)

  • Lee, Dae Wung;Lee, Jung Hun;Choi, Hong Yun;Lee, Chung Dea;Lee, Sin Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.427-427
    • /
    • 2022
  • 하천에서 유사량 자료는 하천의 이·치수 목적으로 활용할 수 있는 기본 자료중 하나로서 하상 변동 예측, 저수지 퇴사량 추정, 하도 계획과 설계, 유사조절 계획 수립 및 기타 구조물 등의 영향 평가 등 다양하게 활용할 수 있다. 본 연구에서는 신뢰성 높은 유사량 자료를 생산하기 위하여 국가유사량관측망 중 27개 지점에 대하여 유사량의 측정 및 특성분석을 수행하였다. 유사량 측정과정은 사전조사, 현장측정, 실험실분석, 모형적용(총유사량 산정) 단계로 구분할 수 있다. 사전조사 단계에서는 현장관련 정보를 수집하여 현장측정 계획 및 현장 안전대책을 수립하고, 현장측정 단계에서는 사전조사 단계에서 수립한 계획을 바탕으로 유사량을 측정하였다. 유사량 측정시 측선은 ISO 기준 이상의 5~7개로 측선을 나누어 측정하였고, 측정장비는 D-74, DH-48 부유사 채취기를 이용하여 왕복수심적분법으로 수행하였다. 실험실분석은 한국수자원조사기술원 유사량 실험실에서 채취시료에 대한 농도, 레이저회절법을 이용한 입도분석, 하상토분석(체분석), 비중실험을 수행하였다. 총유사량 산정을 위한 모형적용 단계에서는 수정-아인슈타인법(Modified Einstein Method)을 적용하였다. 또한, 유량-부유사량 농도 변화양상과 부유사량 특성 분석을 이용한 부유사량 측정결과를 평가하였고 각 지점의 부유사량특성을 잘 나타낼 수 있는 지수식(Qss = aQb)을 이용하여 유량-부유사량관계곡선식을 개발하였다.

  • PDF

Development of Relative Calibration Method for Measurement of Radon and Application (라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.243-250
    • /
    • 1997
  • A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{\pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$ respectively.

  • PDF

전기폭발법에 의해 제조되는 금속나노분말의 크기분포 실시간 측정

  • Lee, Seung-Bok;Bae, Gwi-Nam;Im, Seong-Sun;Lee, Dong-Jin;Park, Jung-Hak
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.58.2-58.2
    • /
    • 2009
  • 금속 와이어를 전기폭발법에 의해 증기 상태로 만든 후 응축시킬 때 제조되는 금속나노분말의 크기특성을 파악하기 위하여 제조장치에 샘플링 포트를 삽입하여 실시간 입자 측정기(Scanning Mobility Particle Sizer; SMPS) 로 14~615 nm 범위의 크기분포를 측정하였다. SMPS는 입자의 크기에 따라 전기적 이동도가 달라지는 원리를 이용하여 공기 중에 부유된 나노입자의 크기분포를 수 분내에 측정하는 실시간 입자 측정기이다. 금속나노분말 제조장치 내부는 약 0.5 bar 수준으로 불활성가스로 채워져 있어서 대기압보다 높은 고압조건이므로 SMPS 전단에 작은 노즐이 삽입된 pressure reducer를 부착하여 적정한 압력 수준으로 낮춘 후 SMPS로 나노분말의 크기분포를 실시간으로 측정하였다. 제조공정이 진행되면서 전기폭발이 주기적으로 발생하는 동안에 SMPS로 측정한 14~615 nm 범위 입자의 총 수농도는 약 $10^7$ 개/$cm^3$ 수준으로 매우 높았고, 약 100 nm와 200 nm에서 고농도 피크를 나타내는 bimodal 분포를 나타냈다. 반면 전기폭발이 잠시 중단되는 경우 입자의 총 수 농도는 약 $10^4$ 개/$cm^3$ 수준으로 낮아지고, 약 20 nm 이하의 입자가 대부분을 차지하면서 입자의 크기가 커질수록 농도가 낮아지는 형태의 크기분포로 바뀌었다. 본 연구를 통해 얻어진 제조장치 내부의 나노분말 크기분포 자료는 고품질 제품을 생산하기 위해 나노분말의 크기분포를 제어하는 분급장치 개발에 활용될 수 있을 것으로 기대된다.

  • PDF

Investigation of Measurement Feasibility of Particulate Matter Concentration by Different Land-Use Types Using Drone (드론을 이용한 토지이용별 미세먼지 농도 측정 가능성 모색 연구)

  • Son, Seung-Woo;Yu, Jae-Jin;Kim, Dong-Woo;Kim, Tae-Hyun;Sung, Woong-Gi;Yoon, Jeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.259-267
    • /
    • 2020
  • This study measured the Particulate Matter (PM) concentration according to altitude (30 m, 60 m, 90 m, 120 m, and 150 m) in three different environments: a construction site, natural environment (arboretum), and residential area. PM2.5 and PM10 values at 30 m above the construction site were 18.63 ㎍/㎥ and 24.23 ㎍/㎥ while values at 150 m were 10.89 ㎍/㎥ and 10.61 ㎍/㎥, respectively, indicating the average concentration decreased as altitude increased. PM2.5 and PM10 values at 30 m above the natural environment were 9.03 ㎍/㎥ and 11.21 ㎍/㎥ while those at 150 m were 3.42 ㎍/㎥ and 3.57 ㎍/㎥, respectively, showing lower average concentrations as altitude increased. PM2.5 and PM10 values at 30 m above the residential area were 10.65 ㎍/㎥ and 12.06 ㎍/㎥ while those at 150 m were 4.24 ㎍/㎥ and 5.17 ㎍/㎥, also demonstrating lower PM concentrations as altitude increased. The PM concentrations decreased as altitude increased at all tested sites and also decreased between environments in the following order: construction site, residential area, and natural environment. The results of this study are significant because PM concentrations were measured at various altitudes at different land-use sites. The results are expected to serve as basic data for decision-making in both regional and urban planning.