• Title/Summary/Keyword: 녹지용적

Search Result 35, Processing Time 0.02 seconds

The Change of the Structure of Green Space by the Change of the Floor Area Ratio in Apartment Complex (용적률 변화에 따른 공동주택 단지내 녹지구조 변화특성)

  • 김정호;이경재;김정호
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.1
    • /
    • pp.42-52
    • /
    • 2004
  • The purpose of this study was to propose the change of green area and green structure according to the change of the Floor Area Ratio(FAR) of apartment complex. The survey site was selected two each of apartment complex after due consider three type that is, the FAR below 100%, the FAR below 250% and the FAR over 250%. Green rate is 40.23~44.23%, green width is 3~15m, green volume is 1.06~1.71㎥/$m^2$, planting density of cannopy layer is 0.04~0.06tree/$m^2$, planting density of understory layer is 0.06~0.20tree/$m^2$ in case of Hwagok 2nd Jugong apartment(FAR 99%) and Gaepo Jugong apartment(FAR 73%) constructed in the 1970~1980. Green rate is 24.16~26.16%, green width is 3~7m, green volume is 0.84~1.54㎥/$m^2$, planting density of cannopy layer is 0.18~0.31tree/$m^2$, planting density of understory layer is 0.15~0.35tree/$m^2$ in case of Deungchon Jugong aparment(FAR 226%) and Gaehwa apartment(FAR240%) construsted in the mid-1990's. Green rate is 23.47~25.53%, green width is 2~6m, green volume is 1.06~2.12㎥/$m^2$, planting density of cannopy layer is 0.25tree/$m^2$, planting density of understory layer is 0.22~0.37tree/$m^2$ in case of Hanbo Guam apartment(FAR 269%) and Donga 3rd apartment(FAR 376%) constructed in the last-1990's. As the results of analysis of green structure according to changes of the Floor Area Ratio(FAR), the greater the FAR, the higher the rate of green area. The green volume and planted density is low without the change of the FAR and planted structure was simple-layer structure composed of alien woody species.

Analysis of Surface Temperature on Urban Green Space Using Unmanned Aerial Vehicle Images - A Case of Sorasan Mt. Nature Garden, Iksan, South Korea - (무인항공 영상을 활용한 도심녹지 표면온도 특성 분석 - 익산 소라산 자연마당을 대상으로 -)

  • CHOI, Tae-Young;MOON, Ho-Gyeong;CHA, Jae-Gyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.90-103
    • /
    • 2017
  • This study analyzed the surface temperature characteristics of urban green spaces under high summer temperatures to clarify the functions of green spaces in reducing urban temperatures. We obtained accurate surface temperature data using highresolution unmanned aerial vehicle images of the survey site, which was an isolated green space in the city. We analyzed differences in the surface temperature by land cover type, vegetation type, species type, and the relationship between surface temperature and vegetation volume. Based on the results, among the land cover types, wetlands and forests had low temperatures and paving areas had very high temperatures. Regarding vegetation type, broad-leaved trees had lower temperatures than coniferous trees in forests. However, in planted areas, coniferous trees had lower temperatures than broad-leaved trees. The temperature of long grass was higher than that of short grass, which suggested that the volume of grass affected the temperature. Regarding forest species type, the temperature of broad-leaved Robinia pseudoacacia forest and mixed broad-leaved forest was lower than coniferous Pinus densiflora forest. There was a slight difference in temperature between R. pseudoacacia forest and mixed broad-leaved forest. The analysis of the relationship between vegetation volume and temperature by forest species type indicated a negative correlation, where the temperature decreased with increasing vegetation volume, similar to the results of previous studies. However, we found a weak positive correlation in R. pseudoacacia forest; therefore, an increase in volume may not reduce the surface temperature depending on the dominant species.

Analysis of Temperature Profiles by Land Use and Green Structure on Built-up Area (시가화지역 토지이용 및 녹지구조에 따른 온도변화 연구)

  • Hong Suk-Rwan;Lee Kyong-Jae;Han Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.19 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • This study was conducted selecting 44 places with a block unit subject to urban area in Gangnam-gu, to analyze a temperature change according to land use and green structure. In this study, it was used the broad-wide urban temperature, supported by Landset TM and ETM+ satellite image 6scene(1999${\~}$2002). The result of the research, the land use pattern has slightly influence on a temperature change of urban area. The result from correlation analysis between temperature and the factors affected by land cover type, such as building-to-land ratio(A correlation coefficient is 0.368${\~}$0.709) have positive correlation and green area ratio(a correlation coefficient is -0.551${\~}$-0.860) have negative correlation. The result from correlation analysis between temperature and green capacity of the land, crown projection area ratio, each factor have negative correlation with temperature, as showing that a correlation coefficient of green capacity of the land is -0.577(June 2006)${\~}$-0.882(June 1999) and crown projection area ratio's is -0.549(June 2001)${\~}$-0.817(June 1999). The result of the regression analysis for establishing urban area temperature change prediction model showed that green capacity of the land of the explanation variable was accepted.

Change of Green Space Arrangement and Planting Structure of Apartment Complexes in Seoul (서울시 아파트단지의 녹지배치 및 식재구조 변화 연구)

  • Lee, Dong-Wook;Lee, Kyong-Jae;Han, Bong-Ho;Jang, Jae-Hoon;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.1-17
    • /
    • 2012
  • This study was carried out to propose the improved method by analyzing the change of green space arrangement and planting structure of apartment complexes in Seoul. 12 survey sites, which have obvious differences, were selected by reflecting the change of floor area ratio, underground parking place, and green space ratio. We divided the survey sites into four types that high green ratio(over 40%) apartment on natural ground, low green ratio(under 40%) apartment on natural ground, low green ratio(under 40%) apartment on artificial ground, and high green ratio(over 40%) apartment on artificial ground each period based on green space ratio and ground structure, plant crown volume, planting density, and planting pattern. The main factors of change of green space arrangement were green space ratio and ground structure. The Green space ratio was changed by the floor area ratio with constructing underground parking place and floor area ratio was adjusted by government policy and economic status. Average width of front green area has been changed from 10.0m in high green ratio apartment on natural ground for 3.5m, 2.7m, and 4.5m each period. The average width of the buffer green area has been changed from 15.0m in high green ratio apartment on natural ground of 7.7m, and 2.7m by extending parking place in the low green ratio apartment of artificial ground, so buffer green areas have been reduced and disconnected. So buffer green area in apartment complexes has been extended that the average width of the buffer green area was 3.8m caused by growing recognition of green since 2001. The ratio of native plant in canopy layer was increased from 45.1 % in the case of the high green ratio apartment of natural ground in 1980~1983 to 55.6%. Average plant crown volume increased from $1.27m^3/m^2$ in high green ratio apartment on natural ground for $3.47m^3/m^2$ in a low green ratio apartment on natural ground. But average plant crown volume is $0.27m^3/m^2$ in the high green ratio apartment of the artificial ground plant density of canopy layer was changed from 5 individuals per $100m^2$ to 14.5 individuals per $100m^2$. We should construct the buffer green area with natural ground and get the function of ecological and beautiful environment regarding to garden concept in case of front green area, width 4.5m. We should get the function of increasing green volume by multi-layer planting with shade woody species and flower woody species in case of back-side green area, width over 5.0m. We should get the function of covering the wall and increasing green landscape by planting with high woody species in case of side green area. We should apply the ecological planting technique to buffer green area and connect buffer green area to inner green area in apartment complexes.

Study on Analysis of Influence Factor for Wildbirds' Appearance in Urban Area around Urban Green Axis - A Case Sturdy of Gangdong-gu in Seoul - (도시 녹지축 주변 시가화지역 내 야생조류 출현 영향요인 분석 연구)

  • Kwak, Jeong-In;Lee, Kyoung-Jae;Han, Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.2
    • /
    • pp.166-177
    • /
    • 2010
  • This study is to identify potential factors to impact on appearance of wildbirds which live in the core forest around urban area in Gangdong-gu, Seoul. As a result of analysis of, studies on biotope showed most of urbanization biotope was biotope of residential areas with high green coverage and biotope of residential and business areas with low green coverage while most of biotope of green and openspace was core green biotope. The research area was divided into several blocks based on biotope types in the urbanization areas excluding green and openspace. As a result of research on wildbirds, total 51 species 3,419 individuals appeared in spring and total 35 species 4,213 individuals appeared in winter. 24 wild bird species were selected as subjects of this study among 31 species seen in urbanization areas, since urban birds, rapacious birds, waterside birds were excluded from the study for the proper consideration. Then this study looked at how many species and individuals of the subjects were observed at each research block in urbanization areas during spring and winter separately. Landuse structure and green structure in each block were examined to see whether these structures affect the number of wild birds observed in urbanization areas of Gangdong-gu. Furthermore, the distance between these blocks and green was assessed. While studying the potential links between the landuse structure and the number of wild birds observed in urbanization areas of Gangdong-gu, block area, green coverage, and building-to-land ratio were believed to affect the number of types and species of wild birds in the research area. In terms of correlation analysis of whether green structure affected the number of wild birds observed in urbanization areas of Gangdong-gu, crown volume of layers, the average green patch area, the average height of canopy layer were found to have an impact not only on the number of types but also species of wild birds in the research area.

A Study on Air Temperature Reduction Effect and the Functional Improvement of Street Green Areas in Seoul, Korea (서울 도심 가로수 및 가로녹지의 기온 저감 효과와 기능 향상 연구)

  • Jung, Hee-Eun;Han, Bong-Ho;Kwak, Jeong-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.37-49
    • /
    • 2015
  • The goal of this research is to examine air temperature changes according to tree type, plantation type, roadside green area structure, and green volume of street green area within a city. The plantation type that could be analyzed for comparison by tree type with over 3 species was 1 rows of tree+shrubs. The results of analysis of average air temperature difference between pedestrian and car streets vis-a-vis 1 row of tree+shrub in high air temperature areas were: Pinus densiflora, $1.35^{\circ}C$; Zelkova serrata, $1.84^{\circ}C$; Ginkgo biloba, $2.00^{\circ}C$; Platanus occidentalis, $2.57^{\circ}C$. This standard large wide canopy species was analyzed by the roadside to provide shade to have a significant impact on air temperature reduction. In terms of analysis of the relationship between plantation type of roadside trees and air temperature, the average air temperature difference for 1 row of tree type was $1.80^{\circ}C$; for 2 rows of trees it was $2.15^{\circ}C$. In terms of analysis of the relationship between the roadside green area structure and air temperature, for tree type, average air temperature $1.94^{\circ}C$: for tree+shrub type, average air temperature $2.49^{\circ}C$; for tree+mid-size tree+shrub type, average air temperature $2.57^{\circ}C$. That is, air temperature reduction was more effective in a multi-layer structure than a single layer structure. In the relationship analysis of green volume and air temperature reduction, the air temperature reduction effect was enlarged as there was a large amount of green volume. There was a relationship with the green volume of the road, the size of the tree and number of tree layers and a multi-layer structured form of planting. The canopy volume was large and there were a great number of rows of the tree layer and the plantation type of multi-layer structure, which is what is meant through a relationship with the green volume along the roadside. Green composition standards for air temperature reduction effects and functional improvement were proposed based on the result. For a pedestrian street width of 3m or less in the field being ideal, deciduous broadleaf trees in which the canopy volume is small and the structure of the tree+shrub type through the greatest 1m green bend were proposed. For a pedestrian street width of over 3m, deciduous broadleaf trees in which the canopy volume is large and is multi-layer planted with green bend over 1m, tree+mid-size tree+shrub type was proposed.

Improvement Planting Method and Characteristics of Planting Design with Ornamental Trees in Apartment Complex, Seoul (서울시 아파트단지내 조경수목 배식특성 및 개선 연구)

  • 이경재;한봉호;이수동
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.2
    • /
    • pp.236-248
    • /
    • 2004
  • This study was carried out to propose improvement planting method by the research and analysis of planting concept, planting density, planting style and pattern in apartment complex, Seoul. Survey sites were selected by reflecting the change of green area ratio : Hawgok Jugong apartment complex, Gangseo-gu(1974), Samik-green apartment complex, Gangdong-gu(1980), Dongsindaea apartment complex, Gangseo-gu(1992). Green area in apartment complex was classified with front green area, side green area, and back-side green area. Planting concept that composed of landscape planting concept but anyother concept was not, was similar to all sites not differ from creation time. And planted species was not differ from planting style. Planting density was of both conopyㆍunder story layer was 0.0∼0.2 tree/$m^2$, and that of shrub layer was 0.0∼0.5 tree/$m^2$ Shrub layer planting density was insufficient and the density was not changed according to the creation time. Canopyㆍunderstory and shrub was planted to another green space, not concern with multi-layer structure. Planting pattern was utilized to single planting, linear planting, and random triangle planting, but it was not to the change that in each green space planting concept. Green area in apartment complex should be variety according to planting density, planting structure and planting pattern. And we should get the function of covering and beauty in case of front green space, that of ecological environment and increasing green volume in case of back-side green area, that of increasing green volume in case of side green area, apartment complex.

A Study of Factors Influencing of Temperature according to the Land Cover and Planting Structure in the City Park - A Case Study of Central Park in Bundang-gu, Seongnam - (도시공원의 토지피복 및 식재구조에 따른 온도 영향요인 규명 연구 - 성남시 분당구 중앙공원을 사례로 -)

  • Ki, Kyong-Seok;Han, Bong-Ho;Hur, Ji-Yeon
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.5
    • /
    • pp.801-811
    • /
    • 2012
  • The purpose of this study is to find out how land cover and planting of an urban park influence temperature. Field research on the land cover and planting status was conducted for Bundang Central Park in Sungnam-si. 30 study plots in the site were selected to closely analyze land cover type and planting structure. The temperature was measured 10 times for each plot. Land coverage type, planting type, planting layer structure and green space area (the ratio of green coverage, GVZ) were chosen as factors impacting temperature and statistics were analyzed for the actual temperature measured. Analysis on how the land coverage type influences temperature showed that planting site had a low temperature and that grassland and paved land had a high temperature. When it comes to planting type, the temperature at the land planted with conifers and broad-leaved trees was low, while the temperature at grassland and paved land was high. With regard to planting layer structure, canopy and canopy-underplanting type showed low temperature, while grassland and paved land showed high temperature. An analysis on the relation between green space area and temperature found out that both ratio of green coverage and GVZ had a high level of negative correlation with the temperature measured. According to regression model of green space area and the temperature measured, for every 1% increase in the ratio of green coverage, temperature is expected to lower by $0.002^{\circ}C$. Also, for every $1m^3/m^2$ increase in GVZ, temperature is expected to go down by $0.122^{\circ}C$.

무주택 우선공급 75% · 용적률 169%의 저밀도 전원도시

  • Kim, So-Jin
    • 주택과사람들
    • /
    • s.193
    • /
    • pp.64-65
    • /
    • 2006
  • 부산 최대 규모의 생태 신도시로 조성되는 정관신도시의 분양이 6월에 실시된다. 정관신도시는 녹지율 25%, 용적률 169%의 친환경 생태 도시로 만들어질 예정이어서 수요자들의 눈길을 끌고 있다. 정관신도시의 개발 방향과 업체별 분양 규모, 수요자들의 청약 전략에 대해 알아보자.

  • PDF

Analyses on Comparison of UTCI, PMV, WBGT between Playground and Green Space in School (학교 운동장과 녹지공간의 UTCI, PMV, WBGT 비교 분석)

  • Yoon, Young-Han;Park, Seung-Hwan;Kim, Won-Tae;Kim, Jeong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.1
    • /
    • pp.80-89
    • /
    • 2014
  • This study of the school's outdoor space for relaxing and activity of the two most numerous students, high heat and low heat with a green space, playground targets of thermal comfort indicators UTCI, PMV, WBGT using the thermal comfort students feeling compare the analyzed. The destination of this study, school facilities of Nam-gu, Namdong- gu, Incheon were studied and the investigation period was conducted from July to August. List of measurement, in the case of thermal comfort indicators, UTCI, PMV, WBGT was measured in the case of green, ratio of green coverage and GVZ was measured. GVZ analysis were as follows: A school ($4.71m^3/m^2$) B school ($3.34m^3/m^2$) C school ($0.38m^3/m^2$). Comparative analysis of the results of thermal comfort indicators by schools, UTCI was Green space $26.15{\sim}31.38^{\circ}C$ and playground $40.66{\sim}42.94^{\circ}C$, PMV values were 1.76 to 2.66 as a green space. WBGT was Green space $26.15{\sim}31.38^{\circ}C$, playground $31.67{\sim}34.53^{\circ}C$. Comparative analysis of the results of thermal comfort indicators UTCI, PMV, WBGT all A school, B school, C school, on the green space was comfortable levels more than playground. The results of the school type thermal comfort and green correlation analysis of thermal comfort UTCI, PMV, WBGT all solar radiation, globe temperature, and a positive correlation shown solar radiation, globe temperature is not comfortable, the higher was considered. UTCI, PMV, WBGT of thermal comfort indicator all ratio of green coverage, GVZ and negative correlation appears ratio of green coverage, GVZ was increased due to the lowering of the value of thermal comfort indicators was considered to be comfortable.