• Title/Summary/Keyword: 녹색캠퍼스

Search Result 21, Processing Time 0.031 seconds

A Study on the Image Evaluation and Morphological Elements of Buildings In the University Campus (대학캠퍼스 건축물의 형태적 요소 및 이미지평가에 관한 연구)

  • Kim, Cheon-Il;Kim, Ick-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • This study evaluates the relationship among the evaluation structure of morphological elements, the satisfaction on exterior elements, and the image evaluation for the campus landmarks by campus type. The investigation results are summarized as follows. 1) The university headquarter was nominated as the university landmark, and the main reason for the nomination was the building's historic and locational value. 2) Of the morphological elements of the campus landmark, 'proportion and balance' and 'harmony and order' were deemed important, while 'diversity' was deemed less important. 3) For the satisfaction on the facility's exterior elements, the evaluation structure was different for each university. However, the factor of 'location of the facility' was deemed the biggest factor for satisfaction for all universities, while the facility's 'color and material' were found to be the most dissatisfying factors. 4) The image evaluation on the facility was different for each university. Although there was a strong skeptical image about 'liveliness', there was a very positive image about 'elegance' and 'scale'. 5) On the relationship between the satisfaction on exterior elements and the image evaluation, there was a different evaluation structure for each university. 'Facility's color and exterior material' were the main elements which improved the overall image of the facility. Thus, the study results strongly suggest that an important task is to determine the maintenance direction through the emphasis on the relationship between exterior elements and image satisfaction for each university.

Study on Water Cycle Performance Evaluation Experiment of Permeable Block (투수블럭의 물순환 성능평가 실험에 관한 연구)

  • Jang, Young Su;Park, Jong Bin;Lee, Jae Hyuk;Kim, Jae Moon;Jung, Min Ho;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.331-331
    • /
    • 2020
  • 급격한 산업화와 도시화로 인한 도시유역의 불투수면의 증가와 이에 따른 배수능력의 저하로 인해 도시 물순환의 왜곡이 발생하였다. 따라서 과거 도시 물관리 기법의 한계가 나타났으며 이를 위해 저영향개발 기법 등과 같은 도시 물관리 기법의 패러다임이 변화하였다. 본 연구에서는 저영향개발 기법에서 도시유역 내 활용이 유용한 침투형 시설 중 투수블럭에 대한 물순환 성능평가를 실외실험을 통해 분석하였다. 성능평가 실험은 부산대학교 양산캠퍼스 한국 GI&LID 센터 내 투수블록 뿐만 아니라 블록 하부 골재층까지 설치가 가능하도록 되어있어 실제 현장과 유사한 환경을 구축이 가능한 2.4×10.9×0.4 (m) 규모의 주차장형 LID 실증시험시설을 활용하였다. 인공강우 분사를 위한 실외 인공강우모사 장치 크기는 2×2(m)으로 본 시험을 위하여 5개의 인공강우모사 장치를 연결하여 활용하였으며, 본 시험장치는 강우를 공급하기 위한 수조와 펌프, 일정한 유량을 유입하기 위한 유량계, 강우를 분사하기 위한 노즐, 인공강우가 실제 강우와 같이 자유낙하 하도록 구현하기 위한 오실레이터 등으로 구성되었다. 시험대상인 틈새투수블록은 석재블록 규격 400×600×100 mm이며 재질은 받침안정층(흙), 투수블록(화강석)으로 구성되어 있다. 실험의 시나리오는 시험체에 강우강도 30mm/hr, 50mm/hr, 100mm/hr에 해당하는 양을 1시간 동안 유입하여 시험 시작 후, 강우지속시간, 표면유출지속시간, 표면유출량을 1분 단위로 측정. 시험체에 유공관이 설치된 경우에는 침투유출지속시간, 침투유출량도 함께 1분 단위로 측정하였으며 각 강우강도별로 측정하고, 1회 측정 후, 각 시험별 시험 대상체의 조건을 같게 하기 위한(하부 지반의 건조) 약 3일 이후(상황에 따라 변동 가능) 시험하였다. 본 실험의 결과, 강우강도가 30 mm/hr와 50 mm/hr인 경우에는 화강석 틈새투수블록포장에서 지표 유출이 발생하지 않았으며, 강우강도 100 mm/hr의 경우 260 L의 지표 유출이 발생하여, 불투수표면 대비 84%의 지표유출 저감률을 보여줌으로서 투수블럭에 물순환 성능에 대한 효과를 분석하였다.

  • PDF

A Study on the Evaluation of Landscape Elements in Outdoor Space at University Campus (대학캠퍼스 외부공간 경관요소 평가에 관한 연구)

  • Kim, Ick-Hwan;Kim, Cheon-Il
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.3
    • /
    • pp.58-67
    • /
    • 2013
  • This study is to analyze the satisfaction and the image evaluation of landscape elements in outdoor space by types of the university campus. The results are as follows. 1) Out of outdoor elements at university campus, planting area, resting area, access road, and water feature are recognized as major landscape elements. Among them, planting area and access roads are evaluated low in terms of satisfaction levels, therefore, improvement on these elements are required. 2) In outdoor space image evaluation, university campus has image such as 'simple', 'clear', and 'safe'. By scale of universities, both 'A' university, which is the biggest in terms of size of campus, and 'B' university, which has a medium sized campus, have a positive image. However, 'C' university, which is the smallest in terms of size of campus, has a passive and negative image. 3) 6 factors are extracted through Factor Analysis for image evaluation. All of the universities show positive image in the categories of 'clarity' and 'familiarity', however, 'B' university and 'C' university show negative image in the category of 'scale'. 4) In Correlation Analysis between landscape elements satisfaction level and image evaluation, it is showed that the group of landscape facility becomes a relation factor of overall image evaluation. As a result, the higher satisfaction level goes, the better image evaluation of overall outdoor space at university campus is.

Hydrological performance analysis of green wall through indoor experiment (실내실험을 통한 벽면녹화에 따른 물순환 효과 분석)

  • Ji Hyun Moon;Jae Rock Park;Soon Chul Kwon;Jae Moon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.302-302
    • /
    • 2023
  • 최근 도시의 왜곡된 물순환 문제를 해결하기 위해서 저영향개발(Low Impact Development, LID) 기법을 적극적으로 도입하고 있다. 저영향개발은 자연의 침투, 증발산, 여과 등의 자연기작을 모방하여 강우유출수를 침투 및 저류시키는 기법으로 물순환 체계를 회복시킬 수 있다. 저영향개발 기법의 하나인 벽면녹화는 건축물이나 기반 시설물의 벽면과 같은 인공지반에 기반을 조성하고 식물을 식재하는 시설로 짧은 시간에 녹지 면적을 만들 수 있다. 또한, 건축물로 인해 생겨난 수직적인 면을 녹지로 활용할 수 있어 도시에 매우 특화된 시설이다. 본 연구는 벽면녹화의 저영향개발 시설로서의 성능을 확인하기 위해 실내 실험을 진행하여 강우유출수 저감효과 및 지체시간 지연효과를 확인하였다. 강우유출수 저감효과는 유입량 대비 저류량을 기준으로 유출저감률을 산정하여 분석하였으며, 총 유출시간을 측정하여 지연효과를 판단하였다. 벽면녹화 현장실험 대상지는 경상남도 양산시 물금읍 부산대학교 양산캠퍼스에 위치한 한국 녹색인프라저영향개발센터이며, 실내에 플랜터형 벽면녹화 시스템을 적용하였다. 부산시 금정구 2012년~2021년의 강수량을 사용해 백분위수 강우사상을 기준으로 30, 50, 70mm/hr의 강우 시나리오를 선정하였다. 물순환 효과를 판단하기 위해 불투수면을 대조군으로 설정하여 불투수면의 유출이 종료되는 시점까지 지표면 유출을 모니터링 하였다. 그 결과, 30, 50, 70mm/hr 시나리오별 유출률은 91.76%, 92.18%, 94.54%로 불투수면과 대비하여 유출이 적게 발생하였으며 총 유출시간은 불투수면대비 47분, 88분, 58분 증가하여 지연효과가 있음을 확인하였다. 본 연구는 실험을 통해 벽면녹화의 수문학적 성능을 분석하고자 유출량 저감효과와 지연효과를 확인하였다. 추후 다양한 강우 시나리오와 제원에 따라 실험이 수행된다면 더 정확히 벽면녹화의 물순환 효과를 확인할 수 있을 것이다.

  • PDF

A Local Monitoring System for Online Electric Vehicle and Infra using Mobile Devices based on Wireless Intranet (모바일 기기를 이용한 무선 인트라넷기반 온라인 전기 자동차 및 인프라 근거리 모니터링 시스템)

  • Oh, Keunhyun;Kim, Sangtae;Kim, Jongwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.1059-1060
    • /
    • 2011
  • 녹색 성장을 위한 전기 자동차 실용화에 대한 다양한 방법들이 제시되고 있다. 이를 효과적으로 운영 관리 하기 위한 시스템들이 개발되고 있다. 기존 연구는 무선 급집전 전기 자동차와 인프라의 특성을 반영하고 접근 편의성에 어려움이 있다. 본 연구에서는 한국과학기술원에서 연구개발 중인 OLEV 시스템을 근거리에서 운영관리 하기 위한 설계를 제안한다. 무선 인트라넷 환경을 구축함을 통해 이동하는 차 안에서 차량의 상태와 동작 중인 충전 인프라의 상태를 함께 관제할 수 있도록 하였다. 이동성과 개인 사용성을 위해 모바일 기기를 이용하여 관리의 유용성과 일반인들의 전기 자동차에 대한 이해를 향상시켰다. 시스템의 유용성을 입증하기 위해 서울대공원 코끼리 전기열차와 한국과학기술원 문지 캠퍼스에서 주행 실험을 수행하였다.

A Study on Automatic Solar Tracking Design of Rooftop Solar Power Generation System and Linkage with Education Curriculum (지붕 설치형 태양광 발전 시스템의 태양 위치 추적 구조물 설계 및 설치 실증 기법의 교육과정 연계)

  • Woo, Deok Gun;Seo, Choon Won;Lee, Hyo-Jai
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.387-392
    • /
    • 2022
  • To participate in global carbon neutrality, the Korean government is also planning to carry out zero-energy building certification for all buildings by 2030 through the enforcement decree of the 'Green Building Support Act'. Accordingly, the government is providing various projects related to solar power generation, which are relatively close to life. In particular, roof-mounted photovoltaic power generation systems are attracting attention in terms of using unused space to produce energy without destroying the environment, but low power generation efficiency compared to other photovoltaic power generation facilities is pointed out as a disadvantage. Therefore, in this paper, to solve this problem, we propose an efficient solar panel angle variable system through research on the solar panel structure for single-axial solar tracking, and also consider the application environment of the roof-mounted solar power generation system. Suggests measures to prevent damage and secondary damage. In addition, it is judged that it is possible to control the solar panel based on ICT convergence and configure the accident prediction safety system to link the project-based education program.

Cities as Place for Climate Mitigation and Adaptation: A Case Study of Portland, Oregon, USA (기후완화와 적용의 장소로서의 도시 - 미국 오레건주 포트랜드시 사례연구 -)

  • Chang, Hee-Jun;House-Peters, Lily
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.1
    • /
    • pp.49-74
    • /
    • 2010
  • Cities are major sources of greenhouse gas emissions but also suitable places for implementing proactive climate mitigation and adaptation strategies. Based on the interdisciplinary review of literature, we categorize the current discussion about urban climate mitigation and adaptation planning, policy and practices into four perspectives - sustainability science, global change science, multilevel governance, and structural engineering. While these four schools of thought have distinct perspectives rooted in different disciplinary lenses, our synthesis of the literature identifies several universal themes that are common to all of the perspectives in the context of combating threats posed by climate change. The Portland case study illustrates that a city can make changes to reduce greenhouse gas emissions and increase adaptive capacity to climate change impacts by implementing smart growth, devising local climate action plans that target emission reductions in various sectors, recognizing the interactions and influences of multiple scales of governance, and supporting the installation of various green infrastructures that contribute to green economy. Furthermore, a university can serve as a hub in this climate mitigation and adaptation arena by connecting various levels of community organizations in both public and private sectors, creating innovative research centers and spatially explicit green infrastructure, designing impact assessments and campus carbon inventories, and engaging students and the larger community through service learning.

Comparison of Heat Collection Performance of Water Heating System Using Fixed and Azimuth-Tracking Solar Collectors (고정식과 방위추적식 태양열 급탕시스템의 집열성능 비교)

  • Lee, Jong Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.191-196
    • /
    • 2014
  • The solar water heating system is one of the seven green campus items installed at the Gangneung campus of Gangneung-Wonju National University. The solar water heating system has two types of solar collectors, four storage tanks and monitoring equipment. Fixed and azimuth-tracking solar collectors were installed to collect heat from the sun. The amount of heat collected by the two different types of solar collectors was calculated from the temperature of the monitored storage tanks. Our results showed that the amount of solar heat collected by the azimuth-tracking solar collector was 19% greater on a sunny day and 23% greater on a rainy day than that collected by the fixed solar collector; therefore, the azimuth-tracking solar collectors are, on an average, 21% more efficient than the fixed solar collectors.

Psychological Stability Color for The Fire Escape Mobile App (심리적 안정감을 주는 화재 피난 모바일 앱(App) 컬러연구)

  • Lee, Sang ki;Park, Hae Rim
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.106-116
    • /
    • 2022
  • As part of the Fire Evacuation Service scenario using mobile applications, this study aims to find the appropriate colors to be used in the interface of the application and to define and apply colors that can positively and reliably affect human unstable psychology in the course of evacuating the room in case of fire. In the situation of fire, proper design and placement of the colored escape guidance interface is important, taking into account the psychology of the occupants. However, literature and previous research have shown that colors used to induce evacuation are not suitable for effective evacuation in case of fire. In this study, the purpose of the study was to provide a color that would provide psychological stability in the event of a evacuation in consideration of the psychological issues of those who are still in need of shelter, and to use it to help induce an efficient evacuation in the event of a disaster. Using the image evaluation method, the form and color of images have been derived through frequency analysis to a number of unspecified people, and the main and secondary colors of images were analyzed through KSCA color analysis. Finally, the final application color was constructed through mutual verification between the results by comparing and analyzing the colors obtained through the image evaluation analysis results and the KSCA color analysis results. The results of the study showed that the green line can help stabilize the human mind through comparative analysis with prior research. Therefore, the main color for guiding calm and calm applications in case of fire escape is proposed in the green line. In this study, the experiment with image evaluation cannot accurately measure the effect of factors on color among complex factors. A subsequent study of this will help quantify images if it allows the subject matter of color and image to be defined to some extent through factor analysis.

A New Perilla Variety 'Bomnaeyeop 1 ho' with Laborsaving Plant Type (노력절약형 엽채소용 잎들깨 신품종 '봄내엽1호')

  • Seong, Eun Soo;Goh, Eun Jeong;Yoo, Ji Hye;Lee, Jae Geun;Kwon, Soon Sung;Lee, Ju Kyung;Lim, Jung Dae;Kim, Myong Jo;Chung, Ill Min;Yu, Chang Yeon
    • Korean Journal of Breeding Science
    • /
    • v.42 no.6
    • /
    • pp.707-710
    • /
    • 2010
  • A new perilla cultivar, 'Bomnaeyeop 1 ho' was developed by, Kangwon National University in 2008. Its characteristics were investigated three times from 2006 to 2008 under optimal condition of cultivation. 'Bomnaeyeop 1 ho' can be characterized by dark green leaf color and tall plant height. This cultivar has more number of flower cluster and ear per cluster compare to 'Saeyeupsil' control. From result of GC/MS analysis, main compounds consist of perilla ketone, beta-caryophyllene and myristicin in 'Bomnaeyeop 1 ho' cultivar.