Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source (고광도 섬광의 안전지표로서 노출제한거리)

  • Park, Seung-Man;Kim, Sang-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.16-21
    • /
    • 2017
  • A systematic understanding of the effects of high-intensity flash sources on the human eye is strongly needed, not only for proper use of the sources, but for human eye health. In this study, the exposure-limit distance (ELD), indicating the minimal safe distance in case of seeing by chance a high-intensity flash, is proposed. The optical procedures to determine the ELD of a high-intensity flash are clarified, and the dependence of ELD on its parameters such as luminous intensity, duration, and radius of a flash are thoroughly investigated. From this investigation it is obvious that, while being weakly dependent on duration, the ELD is nearly proportional to the luminous intensity and the radius of a flash. The proposed ELD as an intuitive safety-indicating parameter is more useful and intuitive than the other characteristic parameters of a high-intensity flash. The ELD is expected to be an essential parameter as a safety indicator, to characterize the performance of a high-intensity flash and to promote the safety of the human eye.

RFID Distance Bounding Protocol Secure Against Mafia and Terrorist Fraud (테러리스트 공격과 마피아 공격에 안전한 RFID 거리 제한 프로토콜)

  • Kwon, Hye Jin;Kim, Soon Ja
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.11
    • /
    • pp.660-674
    • /
    • 2014
  • RFID system has been used in a variety of services. So, a lot of attacks like a free ride on the service, leakage of property or personal information are known. Therefore, the solutions that address these attacks have been proposed. Among the attacks, mafia fraud, a kind of relay attack, can not be addressed by common authentication protocol. So, Hancke and Kuhn used distance bounding protocol for RFID authentication. After that, Munilla and Peinado modified HK protocol by adding void challenge. So the mafia fraud success probability of adversary is lower than probability of HK protocol. Ahn et al. proposed a protocol that reduces number of a hash computation and traffic than MP protocol. Here, we show that MP protocol can not defend the terrorist fraud and is vulnerable to noise. And we show that also AYBN protocol is vulnerable to mafia fraud and key leakage. Moreover, we propose a new protocol and our experimental results show that our protocol is secure to terrorist and mafia fraud.

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Smart Electric Wheelchair using Eye-Tracking (아이트래킹을 이용한 스마트 전동휠체어)

  • Kim, Tae-Sun;Yoon, Seung-Mok;Kim, Tae-Seong;Park, Hyeon-Kyeong;Park, Seong-Hwan;Kim, Woo-Jong;Jeong, Sang-Su;Jang, Young-Sang;Jung, Hyo-Jin;Park, Su-Bin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.07a
    • /
    • pp.259-260
    • /
    • 2020
  • 기존의 전동휠체어를 사용하는 약자 또는 중증 장애인 등 지체(肢體)가 불편한 사람들이 휠체어 사용 시 생기는 문제점을 해소할 목적으로 시작되었다. 이는 전동휠체어가 보행 기구임에도 자동차에 준하는 교통사고에 대해 무방비하게 노출되고, 중증 장애인에 대한 이동권 보장이 아직 미흡하여 생기는 문제이다. 따라서 본 연구에서는 이러한 문제로 인한 불편함을 해소하고자 아이트래킹을 이용한 스마트 전동휠체어 기술을 적용하고자 한다. 루게릭병 등으로 인해 지체(肢體)의 움직임에 제한이 있는 사람들에게 보호자가 밀어주는 휠체어에 의존하는 것이 아닌 Eye-Tracker를 이용한 시선 추적(Eye-Tracking) 기술로 휠체어 동작이 가능하다. Web-Cam과 라즈베리 파이를 통해 얻은 전·후·좌·우의 영상정보를 디스플레이 화면에 송출한다. 그 후 Eye-Tracking 기술을 이용해 디스플레이 화면에 표시된 전·후·좌·우 이동에 관한 UI(User Interface)룰 사용자가 송출된 영상을 보면서 눈의 움직임만으로 선택해 휠체어의 방향을 제어한다. 또한 전동휠체어의 조작 실수로 다른 행인 또는 장애물과 충돌하는 문제점을 초음파 센서를 이용하여 일정 거리 내에 사물이나 사람이 있을 경우 디스플레이 화면에 경고표시 및 경고음, 각 초음파 센서 위치에 맞는 LED작동으로 사용자들에게 추돌 위험경고와 함께 장애물의 위치파악이 가능하도록 한다. 따라서 스마트 전동휠체어를 통하여 수동적인 움직임이 아닌 능동적이고, 초음파 센서로 인해 안전한 이동이 가능하게 한다.

  • PDF

The study for VOCs analysis in long path by open path FT-IR spectrometer (Open path FT-IR spectrometer를 사용한 원거리의 VOCs 측정에 관한 연구)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • The harmful materials as volatile organic compounds (VOCS) that is easy for gas to be changed from liquid on ambient temperature, those should be controlled by Korea Chemicals Management Association. The VOCs samples should be collected directly in place so that those could be analyzed. Generally but it couldn't avoid to have the risk of analyst. Moreover, if there is the place limited to entrance, it is impossible to collect directly and measure. Owing to such problem, it tried to be solved by open path FT-IR spectrometer that could be studied on the combustion gases within long path and VOCs samples were tried to measure to large volume by remote and real time. Firstly, it was to investigate optimized measured length between the system and benzene sample of VOCs. As result, The optimized measured length was confirmed with 15 meter length and the qualitative analysis could be measured on seven VOC samples. The calibration curve as quantitative analysis of benzene samples could be worked. On the basis of the result, the system as remote monitor could show to have potentiality.

Evaluation of Privately Owned Public Spaces within Detached Housing Areas in Pangyo City - Focusing on the Mixed use Housing Areas (가구내부 공유외부공지의 조성실태에 관한 연구 - 서판교 점포주택지를 중심으로)

  • Park, Kyung Seo;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.157-167
    • /
    • 2016
  • Detached residential housing areas are located in the west part of Pangyo City. Seven areas of them are designated for the displaced residents from their original homes by the city development, in which commercial use on the first floor is permitted. The District Plan for the areas were establishes, and one of its main goals is to secure privately owned public spaces (POPS). This research conducted a post enumeration survey on the POPS on the blocks in the seven areas, which blocks contain inner corridors between two rows of housing units. Analytical review of the survey result reveals that (1) POPS facing roads are mainly being used as parking lots or expansion-spaces for the commercial use on the first floor, (2) inner POPS forming corridors are being neglected and otherwise being used as storage areas or outdoor sub-kitchen spaces, and (3) no consideration has been taken for the continuity of the sloped corridors. Regardless of a few good practices in terms of air circulation and lighting, the POPS in the blocks prove to be limited in following the plan's original design intentions and principles.

Analysis of Near Field for Base Station Panel Antenna(4 X 2 Dipole Array) (기지국용 판넬 안테나(4 X 2 Dipole Array)의 근역장 분석)

  • Lee, Dugro;Park, Ju-Derk;Choi, Jae-Ic;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.473-479
    • /
    • 2004
  • In this paper, power density in near field is calculated about analytic object which has comparatively large volume in considering used wavelength such as cellular base station antenna. Panel sector antenna which is used widespreadly in domestic cellular wireless communication system is modeled and electromagnetic field distribution in reactive near field region is calculated by FDTD (Finite Difference Time Domain) method. After that, antenna gain in far field region is obtain by near to far transformation. Power spectral density in radiated near field is calculated in applying to gain-based model with antenna gain in far field. Finally, compliance distance is obtained in considering the result from radiated near field calculation and basic restrictions on occupational and general public exposure limits in ICNIRP guideline. In the center of main radiating position, the result from gain-based model is -14.55 ㏈m and the result from surface scanning method is -15.75 ㏈m. When the losses from cables and connectors used in measurement are considered, the results from gain-based model and surface scanning method are nearly coincident.

Performance Analysis of Docker Container Migration Using Secure Copy in Mobile Edge Computing (모바일 엣지 컴퓨팅 환경에서 안전 복사를 활용한 도커 컨테이너 마이그레이션 성능 분석)

  • Byeon, Wonjun;Lim, Han-wool;Yun, Joobeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.901-909
    • /
    • 2021
  • Since mobile devices have limited computational resources, it tends to use the cloud to compute or store data. As real-time becomes more important due to 5G, many studies have been conducted on edge clouds that computes at locations closer to users than central clouds. The farther the user's physical distance from the edge cloud connected to base station is, the slower the network transmits. So applications should be migrated and re-run to nearby edge cloud for smooth service use. We run applications in docker containers, which is independent of the host operating system and has a relatively light images size compared to the virtual machine. Existing migration studies have been experimented by using network simulators. It uses fixed values, so it is different from the results in the real-world environment. In addition, the method of migrating images through shared storage was used, which poses a risk of packet content exposure. In this paper, Containers are migrated with Secure CoPy(SCP) method, a data encryption transmission, by establishing an edge computing environment in a real-world environment. It compares migration time with Network File System, one of the shared storage methods, and analyzes network packets to verify safety.

Source-Location Privacy in Wireless Sensor Networks (무선 센서 네트워크에서의 소스 위치 프라이버시)

  • Lee, Song-Woo;Park, Young-Hoon;Son, Ju-Hyung;Kang, Yu;Choe, Jin-Gi;Moon, Ho-Gun;Seo, Seung-Woo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.17 no.2
    • /
    • pp.125-137
    • /
    • 2007
  • This paper proposes a new scheme to provide the location privacy of sources in Wireless Sensor Networks (WSNs). Because the geographical location of a source sensor reveals contextual information on an 'event' in WSN, anonymizing the source location is an important issue. Despite abundant research efforts, however, about data confidentiality and authentication in WSN, privacy issues have not been researched well so far. Moreover, many schemes providing the anonymity of communication parties in Internet and Ad-hoc networks are not appropriate for WSN environments where sensors are very resource limited and messages are forwarded in a hop-by-hop manner through wireless channel. In this paper, we first categorize the type of eavesdroppers for WSN as Global Eavesdropper and Compromising Eavesdropper. Then we propose a novel scheme which provides the anonymity of a source according to the types of eavesdroppers. Furthermore, we analyze the degree of anonymity of WSN using the entropy-based modeling method. As a result, we show that the proposed scheme improves the degree of anonymity compared to a method without any provision of anonymity and also show that the transmission range plays a key role to hide the location of source sensors.

Cryosurgery of Lung with 2.4 mm Cryoprobe: An Experimental in vivo Study of the Cryosurgery in Canine Model (냉동침을 이용한 폐 냉동수술의 동물실험: 냉동수술 방법의 비교 실험)

  • Kim Kwang-Taik;Chung Bong-Kyu;Lee Sung-Ho;Cho Jong-Ho;Son Ho-Sung;Fang Young-Ho;Sun Kyung;Park Sung-Min
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.520-526
    • /
    • 2006
  • Background: The clinical application of cryosurgery the management of lung cancer is limited because the response of lung at low temperature is not well understood. The purpose of this study is to investigate the response of the pulmonary tissue at extreme low temperature. Material and Method: After general anesthesia the lungs of twelve Mongrel dogs were exposed through the fifth intercostal space. Cryosurgical probe (Galil Medical, Israel) with diameter 2.4 mm were placed into the lung 20 mm deep and four thermosensors (T1-4) were inserted at 5 mm intervals from the cryoprobe. The animals were divided into group A (n=8) and group B (n=4). In group A the temperature of the cryoprobe was decreased to $-120^{\circ}C$ and maintained for 20 minutes. After 5 minutes of thawing this freezing cycle was repeated. In group B same freezing temperature was maintained for 40 minutes continuously without thawing. The lungs were removed for microscopic examination on f day after the cryosurgery. In four dogs of the group A the lung was removed 7 days after the cryosurgery to examine the delayed changes of the cryoinjured tissue, Result: In group A the temperatures of T1 and T2 were decreased to the $4.1{\pm}11^{\circ}C\;and\;31{\pm}5^{\circ}C$ respectively in first freezing cycle. During the second freezing period the temperatures of the thermosensors were decreased lower than the temperature during the first freezing time: $T1\;-56.4{\pm}9.7^{\circ}C,\;T2\;-18.4{\pm}14.2^{\circ}C,\;T3\;18.5{\pm}9.4^{\circ}C\;and\;T4\;35.9{\pm}2.9^{\circ}C$. Comparing the temperature-distance graph of the first cycle to that of the second cycle revealed the changes of temperature-distance relationship from curve to linear. In group B the temperatures of thermosensors were decreased and maintained throughout the 40 minutes of freezing. On light microscopy, hemorrhagic infarctions of diameter $18.6{\pm}6.4mm$ were found in group A. The infarction size was $14{\pm}3mm$ in group B. No viable cell was found within the infarction area. Conclusion: The conductivity of the lung is changed during the thawing period resulting further decrease in temperature of the lung tissue during the second freezing cycle and expanding the area of cell destruction.