• Title/Summary/Keyword: 노출가스관

Search Result 29, Processing Time 0.029 seconds

Development of Vibration Prediction Program of Gas Pipeline by Construction Vibration (건설진동에 의한 가스배관의 진동예측 프로그램 개발)

  • Jeong S. Y.;Hong S. K.;Kim J. H.;Koh J. P.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.30-35
    • /
    • 2001
  • Presently, working gas pipelines are being subjected to the influence of construction vibration. Especially on subway and road construction, gas pipelines are being influenced to construction vibration caused by use of construction equipment, passage of a large-sized vehicle and blasting. Buried gas pipelines are subjected to the influence of vibration caused by blast in the vicinity of pipeline, exposed gas pipelines are subjected to the influence of vehicle vibration. Therefore, in the study, it is developed to vibration prediction program of gas pipeline by analyzing measured construction vibration. This program is able to predict vibration of gas pipeline according to field conditions by using the results of structural finite element analysis and empirical equation by reliability analysis. And, this program contains the database of construction vibration. Additionally, this program is able to compute estimated blast vibration equation using measured blast vibration data in the field and to form graph of allowable charging gunpowder per delayed-action with the change of blast velocity. Therefore, field workers are able to predict construction vibration around gas pipeline and estimate safety of gas pipeline.

  • PDF

매립 작업중인 쓰레기 매립지에서 대기중에 유출하는 가스의 분포특성

  • 이해승;이찬기;류돈식
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.61-64
    • /
    • 1997
  • 본 연구는 매립 작업중인 준호기성매립지에서 유출가스를 측정하여, 다음과 같은 결론을 얻었다. (1) CH$_4$가스는 대부분 입형가스포집관에서 유출되며, $CO_2$가스는 총유출량의 약 50% 정도가 입형가스포집관을 통하여 유출된다. (2) 매립지 표면에서는 CH$_4$가스 보다 $CO_2$가스가 많이 유출된다. (3) 법면 복토층은 면적비율이 작으나 가스 발생량이 많으며, 특히 $CO_2$가스의 발생율이 높다. (4) 쓰레기층 표면에서의 CH$_4$가스 발생량은 미소이므로 무시하여도 된다. (5) 쓰레기층 노출, 복토층 다짐정도등에 따라 발생량의 변화를 보인다. (6) 매립부에서 새로 반입된 쓰레기층에서 $CO_2$가스 유출량이 많다. (7) 가스포집관과 복도 표면을 포함한 가스 유출량은 CH$_4$가스 유출이 많으나, 전체로는 $CO_2$가스 유출량이 많다.

  • PDF

An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration (차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구)

  • 박연수;강성후;박선주
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.131-139
    • /
    • 2001
  • In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

  • PDF

Distribution of Gas Extruded from Sanitary Landfill (쓰레기 매립지에서 대기중에 유출하는 가스 분포)

  • 이해승;이찬기
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.63-72
    • /
    • 1997
  • This study presents a surveying of methane and carbon dioxide at sanitary landfills. The following results are obtained. (1) The majority of methane and the half of carbon dioxide pour out from vertical gas vents. (2) The quantity of carbon dioxide in cove. soil was greater than methane. (3) Even though gas extrusion in side slop area was small, the quantity of gas extrusion in side slop area was much greater than in coversoil area as especially carbon dioxide rate. (4) As were carried raw refuse layer, methane extrusion was trace, but carbon dioxide was large. (5) Gas extrusion quantity were changed by the compaction of soil, and the operating area of refuse. (6) Carbon dioxide portioned much larger in the whole landfill, but methane portioned much larger in gas vent and coversoil.

  • PDF

Study on Exposed Piping with High Risk of Fire (화재 위험성이 높은 노출배관 사용에 관한 연구)

  • Kim, Yeob-Rae;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.61-66
    • /
    • 2015
  • PVC pipe has excellent corrosion resistance and chemical resistance and is broadly used. However there are no regulations regarding exposed piping material in buildings. There is growing concern about the vulnerability of piping to fires and generating toxic gas. Exposed piping should be made of incombustible materials to prevent spreading of toxic gas and to minimize damage to life and property in case of fire. Many big structures are being built, and concerns regarding damage by fire are continuously growing. In these circumstances, we should reinforce fire safety standards for buildings and heighten safety consciousness to become a well-developed country. For these reasons, we investigated the materials used for exposed piping and the standards of well-developed countries to enhance safety. We tried to figure out the alternatives by examining the actual conditions of each region's buildings. Based on the use of incombustible materials for exposed piping in each region, we tried to enhance the effectiveness for safety by suggesting revisions for related laws and regulations.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

AE Characteristic of Polyethylene Pipe under various defects (다양한 결함에 대한 폴리에틸렌 배관의 음향방출 특성)

  • Nam Ki Woo;Lee Si Yoon;Ahn Seok Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.1-7
    • /
    • 2004
  • The polyethylene pipe can use semi-permanent because of the high corrosion resistance with chemical stability. In addition to, there is the merit that is an easy to establish and to maintain. However, as the reason that it is simply degraded when the polyethylene pipe was exposed to the outside, mainly it is used to lay under the ground with low-pressure gas transportation pipe. In this study, the nondestructive evaluation method was used to maintain the integrity of the polyethylene pipe. We simulated the various defects on the polyethylene pipes, and then the AE signal occurred according to the impact test of steel ball was evaluated by the acoustic emission method. From the results, the waveform and dominant frequency could be distinguishing from the defect shapes of polyethylene pipe. Especially, in the case of notch defect, the AE signals occur different by the angle and depth of the notch.

  • PDF

Blast Excavation of Small Diameter Tunnel near Underground pipe lines (지하 관 시설물과 인접한 소규모 단면 터널의 발파굴착 사례)

  • Won, Yeon-Ho;Kim, Kang-Gyu
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.40-54
    • /
    • 2010
  • The messer shield method applys mainly to a tunnel with small cross-section of a weathered soil or weathered rock district and is fulfilled mostly by man-power excavation. but in case that hard rock exposes on tunnel face, incredible is an application of the rock-splitting method using a hydraulic power or a blasting method. This study represents the case of a blasting method which can control to be practiced by the minimum charges of 125 g an initial vibration occurring at the cut instead of the rock-splitting method, even though water pipe and gas pipe are closely adjacent.

Blood Concentration of Polycyclic Aromatic Hydrocarbons from Non-Occupational Exposure in farming towns near metropolitan Busan, Korea : Environmental Tobacco Smoke and Roasted Food Intake as Influential Factors (부산인근 농촌지역의 비직업적 노출에 의한 혈중 다환방향족탄화수소 농도: 간접흡연과 구운음식 섭취를 중심으로)

  • Moon, Chan-Seok;Jo, Eun-Mi;Lee, Chae-Kwan;Kim, Jung-Man;Hong, Young-Seoub;Son, Bu-Soon;Paik, Jong-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.111-118
    • /
    • 2010
  • 연구목적: 본 연구는 일반인의 비직업적 노출에 대한 혈중 16종의 다환방향족탄화수소(PAHs) 의 농도르 분석하여 PAHs의 백그라운드 노출 농도를 평가하는 것이다. 내용 및 방법: 농촌지역에 거주(비직업적 노출로서 16종 다환방향족탄화수소가 특정한 환경오염을 받지 않은 지역에 거주)하는 156명의 연구 참여자의 혈중 16가지 다환방향족탄화수소 농도의 기하평균치를 간접흡연군, 구운 음식물섭취군과 각대조군을 비교 하였다. 혈중 16종의 다환방향족탄화수소의 농도는 질량분석기를 장착한 가스크로마토그라피법과 헤드스페이스 마이크로고체상 추출법에 의하여 분석하였다. 결과: 연구참여자 중, 간접흡연자들에서 4종의 다환방향족탄화수소 아세나프틸렌(p<0.01), 아세나프텐(p<0.1), 플로렌(p<0.01), 피렌(p=0.05)가 대조군 보다 유의하게 높았다. 또한 구운육류와 생선 섭취군에서는 벤조(a)피렌(p<0.1)이 대조군 보다 유의하게 높았다. 결론: 간접흡연과 구운음식물 섭취는 비직업적 노출에서 다환방향족탄화수소 노출원의 가능성이 높다고 추정된다. 혈중 다환방향족탄화수소는 한국일반인의 비직업적 노출 농도로 사용 가능하다고 생각된다.

Jet A-1 Coking Tests under Conditions Simulating Gas Turbine Combustor (가스터빈 연소기 모사 조건에서의 Jet A-1 코킹시험)

  • Lee, Dain;Lee, Kangyeong;Han, Sunwoo;Ahn, Kyubok;Ryu, Gyong Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • In a gas turbine, fuel is exposed to a high temperature environment until it is fed to the combustor through the injector. Hydrocarbon fuels can coke under high temperature conditions, which can cause coking material to deposit on fuel lines or block the injector passages. In this study, a specimen simulating a fuel line located inside a gas turbine and Jet A-1 were heated using electric devices. Jet A-1 coking tests were performed by changing the wall temperature of the stainless steel specimen and the temperature of Jet A-1 supplied to the specimen. After the coked specimens were cut, the coking material and the inner surface were analyzed using an energy dispersive X-ray spectrometer and a field emission scanning electron microscope.