• Title/Summary/Keyword: 노이즈제거

Search Result 607, Processing Time 0.031 seconds

Design of Filter for Output Signals in Incremental Encoder for Detecting Speed and Position of Motors (전동기 속도 및 위치검출용 증분형 엔코더 출력신호 필터 설계)

  • Ahn Jung-Ryol;Lee Hong-Hee;Kim Heung-Gun;Nho Eui-Cheol;Chun Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.290-295
    • /
    • 2005
  • The incremental encoder has been mostly used to measure the speed and position of the motor. As the output signals of encoder are high frequency digital signals, they have much influence on radiation noises due to switching of the power semiconductor circuits. It is so difficult to suppress the noises with the conventional LPF. In this paper, the hardware digital filter for suppressing noises in the output signals of the encoder signals is developed. As both the clock frequency and counter in the digital filter for encoder are easily adjusted according to the kinds of noises, any noises in the encoder can be entirely eliminated. The performance of the digital filter has been verified by simulation and experimental results.

Performance comparison of Image De-nosing Techniques based on Color Model Transformation (컬러 이미지 변환을 이용한 노이즈 제거 방법 및 성능 비교)

  • Kim, Taeho;Kim, Hakran
    • Journal of Digital Contents Society
    • /
    • v.18 no.8
    • /
    • pp.1641-1648
    • /
    • 2017
  • The main purpose of this paper is to compare the performances of various filters with color images to remove the noise. Furthermore, we suggest a modified de-noising process by the transformation of color model from RGB to another color models, such as HSV and $YC_BC_R$, to improve the quality of de-noising methods encompassing Median, Wiener, and Mean filters. Neither the performance comparison of the de-noising filters with color images nor the converting the color model for better de-noise on the degraded images haven't been performed before. Inspired to make improvements, we conduct experiments with new de-noising process on color images. The result of the experiments is shown that it could assist on certain filters being more reliable techniques.

An internal partial discharge measurement method excepted an external corona noise (외부 코로나 노이즈를 제거한 내부 부분방전 측정기법)

  • 권동진;진상범;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2001
  • The largest problem in applying the elecbical partial discharge measurement method the transformer that has been operated until now is the removal of external corona noise In this thesis, a methcd was studied. to rneasme only fue partial discharge sIgnal due to the defoct in transfonrer except the external corona noise. To find out the types of partial discharge and corona noise within a transfomr, a partial discharge was made in use of a needle-plane electrodes within a model transfonner and, at the same time, an external corona noise was generated in use of a rod-sphere electrcdes in the air around the transformer. Both of a partial clischarge signal caused from an intemat defect within a transformer and an external noise were found at the rogowski coil which was located at transformer earth wire. When the external corona noise, which was separately measured in use of an antenna sensor out of transfonner, was removed from the signal measured on rogowski coil, the signal caused by partial discharge within a transformer would effectively be acquired.quired.

  • PDF

Identification of Contaminated pixels in 10-day NDVI Image (정규식생지수(NDVI) 산출시 발생하는 노이즈 제거에 관한 연구)

  • Yeom Jong-Min;Han Kyung-Soo;Kim Young-Seup
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.113-116
    • /
    • 2006
  • 지표 변수는 지면 근처의 기후변화 및 상태를 파악하는데 중요한 역할을 하기 때문에, 충분히 높은 정확성을 가진 값이 산출되어야 한다. 하지만 이러한 지표 변수는 구름과 눈, 그리고 강수등에 의해서 그 값이 변화하게 된다. 이러한 오차 값을 줄이기 위해 구름제거, 지리보정, 대기보정 등의 위성 전처리 과정이 수행되었다. 하지만 위성 전처리 과정을 수행한 이후에도 정규식생지수 시계열 자료에는 여전히 노이즈가 남아 있기 때문에 이전에 연구에서는 이동 평균등과 같은 다양한 방법으로 노이즈를 제거하고자 하였다. 하지만 이동평균 방법은 참값에 가까운 최고값도 제거하기 때문에 문제점을 가지고 있다. 본 연구에서는 다중 다항회귀식을 이용하여 정규식생지수 시계열 자료 산출시 발생하는 노이즈를 제거 하였다.

  • PDF

Non-Local Means Denoising Method using Weighting Function based on Mixed norm (혼합 norm 기반의 가중치 함수를 이용한 평균 노이즈 제거 기법)

  • Kim, Dong-Young;Oh, Jong-Geun;Hong, Min-Cheol
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.136-142
    • /
    • 2016
  • This paper presents a non-local means (NLM) denoising algorithm based on a new weighting function using a mixed norm. The fidelity of the difference between an anchor patch and the reference patch in the NLM denoising depends on noise level and local activity. This paper introduces a new weighting function based on a mixed norm type of which the order is determined by noise level and local activity of an anchor patch, so that the performance of the NLM denoising can be enhanced. Experimental results demonstrate the objective and subjective capability of the proposed algorithm. In addition, it was verified that the proposed algorithm can be used to improve the performance of the other $l_2$ norm based non-local means denoising algorithms

A Study on the Improvement of ADCP Error by Submerged Vegetation (수중식생에 의한 ADCP 오측 개선 연구)

  • Jeong, Seung Gyo;Hwang, Jae Sung;Lee, Sin Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.233-233
    • /
    • 2021
  • ADCP(Acoustic Doppler Current Profiler)는 유수의 흐름을 방해하지 않으면서 수중에 발사된 음파의 도플러 효과를 이용하여 3차원 유속 측정이 가능한 초음파 유량측정장비이다. 2009년부터 다양한 하천에서 ADCP 사용량이 증가하면서 ADCP를 이용한 유량측정 기법과 현장 적용상의 문제, 자료처리 과정에서의 문제점들이 발생하고 있다. 이런 문제점들을 분석한 결과 다음과 같은 사례들이 나타났다. 첫 번째 하상이 매우 불규칙한 단면의 부적절한 측정 사례, 두 번째 하안 수직벽 존재에 따른 단면의 부적절한 측정 사례, 세 번째 수심 오측이 다수 발생한 측정 사례, 네 번째 유속 프로파일 결측이 다수 발생한 측정 사례, 다섯 번째 통신문제로 인한 주기적인 결측이 발생한 측정 사례, 여섯 번째 홍수기 고농도 유사로 인해 결측이 발생한 사례, 일곱 번째 수중식생의 영향으로 수심 및 유속 프로파일 오측이 발생한 측정 사례, 여덟 번째 이동상 조건이 발생한 측정 사례 등 많은 문제들이 발생하였다. 본 연구에서는 수중식생의 영향으로 수심 및 유속 프로파일 오측이 발생하는 사례에 대해 개선할 수 있는 방안을 연구하였다. ADCP에서 수중에 발사한 음파 중 식생에 부딪친 강한 반사파의 노이즈로 side-lobe현상에 의한 오측 및 결측이 발생한다. 현재 오측 및 결측 자료는 ADCP 제조사별 자료 취득 소프트웨어의 기능에 의존 하거나, USGS의 OSW(Office of Surface Water) Hydroacoustics의 QRev를 이용하여 후처리 과정을 거쳐 측정 자료로 정리하고 있다. 이에 본 연구에서는 노이즈로 인한 side-lobe 현상을 물리적인 방법으로 제거하기 위해 음향 녹음 과정에서 노이즈를 물리적인 방법으로 제거하는 윈드실드와 팝 필터를 고려한 ADCP필터를 개발하여 적용하였다. 이번 연구의 대상지점은 원주시(지정대교)수위관측소로 5월 이후 수중에 식생이 성장하는 지점이다. 먼저 ADCP필터를 제거한 상태에서 측정을 실시하고, 이후 ADCP필터를 장착하여 측정을 실시하였다. ADCP필터 적용의 측정성과에서는 노이즈에 의한 오측 및 결측이 다수 발생하는 것을 볼 수 있고, ADCP필터를 적용한 측정성과에서는 노이즈가 제거되어 오측 및 결측이 개선되는 결과를 볼 수 있었다. 본 연구에서는 수중식생 영향으로 강한 반사파에 의한 노이즈로 side-lobe현상에 의한 ADCP측 정성과의 오측 및 결측을 ADCP필터를 적용하여 물리적인 방법으로 노이즈를 제거 할 수 있다는 결과를 얻었다.

  • PDF

Noise Reduction for the MEG and MCG using the PCA (주 성분 분석법을 이용한 심자도 및 유발자게 신호에서 펄스 잡음 및 뇌자도 잡음 제거)

  • Lee, D.H.;Chang, K.S.;Kim, I.G.;Chung, D.H.;Choi, J.P.;Lee, H.K.;Huh, Y.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2786-2788
    • /
    • 2003
  • 본 논문에서는 생체자기신호의 잡음제거 기법 중 PCA(Principal Component Analysis) 알고리즘을 사용하여 효과적으로 노이즈를 제거하기 위한 방법을 제안하였다. 61 채널 SQUID 시스템을 이용하여 심자도 신호를 측정하였고, 40 채널 SQUID 시스템을 이용하여 뇌자도 신호를 측정하였다. 그리고, 측정한 신호 성분들을 제안한 방법을 이용하여 주성분들을 분리하였고, 이들 중에서 노이즈 성분을 추정하여 측정한 신호에서 제거하였다. 이러한 방법을 이용한 결과, 심자도 신호에 존재하는 펄스 노이즈로 인하여 왜곡된 생체 자기 신호의 노이즈를 감소 시킬 수 있었으며, 뇌자도 신호에 존재하는 외부 노이즈 성분을 제거하여 임상 진단에 유용한 데이터를 얻을 수 있었다.

  • PDF

Binary Image Trimming using Chain Code (체인 코드를 이용한 이진 영상 트리밍)

  • Jung, Min-Chul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.216-219
    • /
    • 2007
  • 본 논문에서는 영상 인식을 위해 그레이 레벨로 획득된 영상을 이진화할 때 발생되어 패턴의 윤곽선을 울퉁불퉁하게 만드는 랜덤 노이즈를 제거하기 위한 방법으로 체인 코드 트리밍(chain code trimming) 을 제안한다. 제안된 방법은 패턴의 외부 윤곽선과 내부 윤곽선의 체인 코드 분석을 통해 랜텀 노이즈의 체인 코드를 제거, 교정함으로서 이루어진다. 실험에서는 트리밍을 사용하기전과, 단순 트리밍을 한 경우, 체인 코드 트리밍을 한 경우를 서로 바로, 분석한다. 실험 결과는 패턴에 첨부되었던 랜덤 노이즈가 모두 성공리에 제거된 것을 보인다.

  • PDF

Adaptive noise removal in the 40-channel MEG system (40 채널 뇌자도 시스템에서 적응 필터를 이용한 노이즈 제거)

  • Lee, D.H.;Shin, W.C.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3213-3215
    • /
    • 2000
  • 뇌자도 신호의 측정은 뇌에서 발생하는 자장 성분을 정밀하게 측정할 수 있으나, 신호의 크기가 매우 작기 때문에 노이즈에 매우 민감하게 동작하며 이러한 노이즈 성분의 발생원인은 외부 환경에 의하여 발생하거나 시스템 내부에서 발생하는 두가지로 나눌 수 있다. 따라서 뇌자도 신호를 측정하는데 있어서 가장 중요한 작업은 신호에 존재하는 노이즈 성분을 제거하는 것이다. 특히 뇌자도 측정 시스템에서는 외부 노이즈 성분을 제거하기 위하여 레퍼런스 채널이 존재한다. 따라서 본 논문에서는 청각 자극 신호에 의한 뇌자도 신호를 측정하고 측정한 데이터를 사용하여 레퍼런스 채널과 입력신호에 대하여 LMS 알고리즘을 이용한 적응 필터를 모델링 하였다. 그리고, 구현한 적응 필터를 이용하여 뇌자도 신호의 평균값, 표준편차의 통계적 결과를 비교하여 모델링한 적응 필터 방법의 유용성을 확인하였다.

  • PDF

The Noise Canceling on Gray Image Morphing by Median Filtering (그레이 이미지 모핑에서의 미디언 필터를 이용한 노이즈 제거)

  • 정은숙;윤호군;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.255-259
    • /
    • 2003
  • The noise canceling on gray image morphing with median filter is presented. The processing is that interpolate the image with B-spline, specify the distinctive points, cancel the noise by median filtering and perform the morphing. The experiment results denoise the blocking degradation as 20%, correct and present a soft morphing image processing.

  • PDF