• Title/Summary/Keyword: 냉방 효과

Search Result 161, Processing Time 0.039 seconds

Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems (증발냉각시스템의 활용실태 및 냉방효과)

  • 김문기;유인호;김기성
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 1999
  • In order to take a good look at effectiveness of cooling of Fog system and Pad-Fan system, we chose 49 farm households which were installed evaporative cooling system and 2 farm households which were installed Pad-Fan system and Fog system for a test. We execute the test on 29 households out of 49.6 households, which were installed Pad-Fan system, were able to use; however, 6 household out of 9 which were installed Fog system couldn't use it. The main reason was the clogged on nozzle. The cooling efficiency on Pad-Fan system was 77.4%, but it was very poor on Fog system. Since there are many problems on Fog system, we need more research on size of fog, the location of nozzle, control of Fog systems.

  • PDF

Study on Improvement of Air Conditioning Units for Anti Aircraft Gun Wheeled Vehicle (차륜형 대공포 냉방장치 성능개선 연구)

  • Jeon, Ki-Hyun;Lee, Dong-Hui;Lee, Boo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1099-1103
    • /
    • 2013
  • A combat vehicle needs to have an air-conditioning unit. Accordingly, new combat systems have tended to apply an integrated heating, cooling, and ventilating system. The air conditioning unit used depends on the combat vehicle's purpose of use. In this study, we studied an air-conditioning unit for an armored combat vehicle as a special use and military specification and tried to improve the air-conditioning unit's performance.

Performance Analysis of Heat Pump System for Greenhouse Cooling (온실 냉방을 위한 히트펌프의 성능 분석)

  • 윤용철;서원명;이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF

Development of Fog Cooling Control System and Cooling Effect in Greenhouse (온실 포그 냉방 제어시스템 개발 및 냉방효과)

  • Park, Seok Ho;Moon, Jong Pil;Kim, Jin Koo;Kim, Seoung Hee
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.265-276
    • /
    • 2020
  • This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 ㎡ was found to be 462,609 W, and keeping the greenhouse under 32℃ without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6℃ than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 최영하;이재한;박동금;권준국;엄영철
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

A Study for Intelligent Load Management based on Queueing System Theory (큐잉 시스템기반 에어컨 지능 부하관리에 관한 연구)

  • Lee, Seung-Chul;Kim, Seok-Hyun;Kim, Seung-Jin;Han, Seung-Woo;Park, Chan-Eom
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.235_236
    • /
    • 2009
  • 본 논문은 전력회사와 수용가가 실시간으로 상호 협력하면 서 여름철 냉방부하를 효율적으로 관리하여 첨두부하를 저감하기 위한 기법에 대하여 기술한다. 전력회사가 필요 관리량을 수용가 측에 요청하면 부하관리 요청을 받은 수용가, 예를 들면 대규모 아파트 단지의 중앙 지능관리 서버가 자율적인 관리를 통하여 요구받은 관리전력 이내로 부하율을 조정하도록 한다. CIMS는 관리전력량에 따라 냉방기를 가동할 수 있는 권리에 해당하는 적정 수의 토큰(Token)을 발행하고 각 세대내의 냉방기를 제어할 수 있는 다수의 로컬 지능관리 서버들이 각 상황에 따라 냉방기를 가동하기 원할 경우에 전체 관리 서버에게 냉방기를 가동할 수 있는 권리에 해당하는 토큰을 요청하도록 한다. 제안하는 관리 기법을 기초로 서울의 한 아파트단지의 여름철 전력수요 데이터를 예로 하여 예상되는 대기 시간과 지원 받을 수 있는 전력요금 규모를 산정해 보았으며 비교적 적은 수용가의 불편으로 큰 부하관리 효과를 얻을 수 있는 것을 알 수 있었다.

  • PDF

A Study on the Estimation of Electricity Demand for Heating and Cooling using Cross Temperature Response Function (교차기온반응함수로 추정한 전력수요의 냉난방 수요 변화 추정)

  • Park, Sung Keun;Hong, Soon Dong
    • Environmental and Resource Economics Review
    • /
    • v.27 no.2
    • /
    • pp.287-313
    • /
    • 2018
  • This paper measures and analyzes cooling and heating demand in Korean electricity demand using time-varying temperature response functions and cooling and heating temperature effects. We fit the model to Korean data for residential and commercial sector over 1999:01~2016:12 and the estimation results show that the growth rate of heating demand is much higher than that of base and cooling demand, and especially the growth rate of heating demand in commercial sector is much higher. And we define the temperature-normalized demand conditioning that monthly temperatures are assumed as average monthly temperatures. The growth rate of heating demand in the estimated temperature-normalized demand is higher than that in the real demand. Our results are expected to be a base data for Winter Demand Management and short-term electricity demand forecasting.

Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House (지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석)

  • Choi, H.C.;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.;Park, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.99-108
    • /
    • 2010
  • The principal objective of this study was to investigate the cooling effects of geothermal heat pump system (GHPS) in farrowing house. A total of 96 sows were allocated to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in summer season. During the experimental period of four weeks, the highest outside temperature observed was approximately $34.1^{\circ}C$, GHPS decrease indoor temperature of pig housing up to $30.9^{\circ}C$, but conventional pig housing was similar to outside temperature. Dust concentrations (maximum 61.4%) of particulate matter less than $10{\mu}m$ (PM 10) in GHPS-housing were lower than the conventional housing. GHPS showed no signigicant difference in carbon dioxide emission, whereas the ammonia gas concentration was significantly decreased in GHPS-housing compared to that of conventional housing. Sows in GHPS-housing showed significantly lower respiratory rate than those of the control group. GHPS did not affect hormone level, litter size and birth weight, but weaning weight of piglets was influenced by GHPS. Feed consumption of sows was significantly increased in GHPS-housing compared to the conventional hosing. These results suggest that GHPS decrease dust concentration, ammonia gas emission and indoor temperature of pig housing and may affect performance in sows and weaned piglets.