• Title/Summary/Keyword: 냉방기

Search Result 289, Processing Time 0.02 seconds

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

An experimental study on the cooling performance of carbon dioxide heat pump system for fuel cell vehicles (연료전지 자동차용 이산화탄소 열펌프 시스템에서의 냉방 성능에 관한 실험적 연구)

  • Kim Sungchul;Park Minsoo;Kim Min Soo;Hwang Inchul;Noh Youngwoo;Park Moonsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.378-383
    • /
    • 2005
  • This experimental study presents the results of the cooling performance test of a $CO_2$ heat pump system for fuel cell vehicles. The experimental facility provides the cool ing and heating environment for cabin and heat releasing component. The test loop is designed to target the cooling capacity of 5kW and its coefficient of performance (COP) of 2.2. The cooling performance of the heat pump system is strongly dependent on the refrigerant charge and the degree of superheat. We carried out basic experiments to obtain optimum refrigerant charge and the degree of superheat level at the internal heat exchanger outlet. The heat pump system for fuel cell vehicles is different from that of engine-driven vehicles, where the former has an electricity-driven compressor and the latter has the belt-driven (engine-driven) compressor. In the fuel cell vehicle, the compressor speed is an independent operating parameter and it is controlled to meet the cooling/heating loads. Experiments were carried out at cooling mode with respect to the compressor speed and the incoming outdoor air speed. The results obtained in this study can provide the fundamental cool ing performance data using the $CO_2$ heat pump system for fuel cell vehicles.

  • PDF

Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle (공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구)

  • Lee, Daewoong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.

A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building (사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구)

  • Jang, Ji-Hoon;Kim, Hyeonsoo;Auh, Jin-Sun;Leigh, Seung-Bok;Kim, Byungseon-Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.

Estimation of Economic Value of Cooling by Upland Farming during Hot Summer (밭농사의 여름철 기후순화기능에 대한 경제적 가치 평가)

  • Hyun, Byung-Keun;Kim, Moo-Sung;Eom, Ki-Cheol;Kang, Ki-Kyung;Yun, Hong-Bae;Seo, Myung-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.6
    • /
    • pp.423-428
    • /
    • 2003
  • Multifunctionality of agriculture which cannot be in trade has internationally an important issue due to its environmental and public benefits. The purpose of this study was to estimate economic value of upland farming in cooling effect during hot summer. Economic value of cooling effect was evaluated by the replacement cost method. To evaluate the cooling effect from July through August, the amount of evapotranspiration in upland was estimated using crop coefficients and soil water coefficients perviously reported by several researchers. In July and August, average crop coefficient of fourteen major upland crops was 1.19 and average soil water coefficient of major textures of upland soil was 0.91. The estimated evapotranspiration in upland from July through August was $1,224{\times}10^6Mg$, and this amount of evapotranspiration can consume $7.1{\times}10^{14}kcal$ of heat. When these values were converted to the price of petroleum, the economic value of cooling effect by upland farming from July through August was about 12 trillion won.

An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions (부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구)

  • Choi, Sungkyung;Lee, Sang Hun;Kim, Sunjae;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

Study on Characteristics Comparison of Unpowered Cooling and Heating Combined Device using Solar Heat (태양열을 이용한 무동력 냉난방 겸용장치의 특성 비교 연구)

  • Lee, Jaehan;Chun, Taekyu;Yang, Youngjoon
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • As the global warming due to greenhouse effect has become serious problem, it is necessary to introduce the technology, for instance, such as diversity or saving of energy to reduce the use of fossil fuel. The purpose of this study was to investigate the characteristics on materials of absorption plate, unpowered and minimum use of power in cooling and heating combined device. As the results, it was observed that, in case of summer, since temperature of absorption device of solar heat(ADSH) was lower than that of no ADSH, cooling effect was insignificant in case of being not installed cold-reservoir. However, in case of winter, heating effect was certified even though the power was not used. At secondhand, the performance of ADSH with Cu was higher 2 times than that of ADSH with Al.

CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity (스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석)

  • Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 2020
  • The natural change of winter night temperature from 00:00 to 04:30 O'clock with the different height of thermal screen in a venlo type glasshouse (W59×L68×H5.9 m) was studied using computational fluid dynamics (CFD). At the early stage of CFD analysis, the room temperature decrease of glasshouse with the 5.9 m height of thermal screen were faster than it with the 4.1m height of thermal screen, but at 2 hr after analysis it was slower than in it with the 4,1m, the temperature difference was 0.6℃ after 4 hr. If we consider that turn on the heater when the temperature were decrease below 13℃ at 1hr after CFD analysis, it is good for energy saving in the glasshouse with the 4.1 m height of thermal screen rather than in it with the 5.9 m height, because of the temperature decrease were slow during 2 hrs after analysis. The airflow at the height of 2 m which were grown tomato were fast and wide in the glasshouse with the 5.9 m height thermal screen rather than in it with the 4.1 m, the speed difference was 0.034m·s-1 at 1hr after CFD analysis. The effect of temperature decrease in summer season were compared with the different height of shading screen from 12:00 to 14:30 O'clock. The height of shading screen were 5.7, 3.9 m, the gap of it were 30%. The air-inflow quantity by the fan with duct at lower part of venlo glasshouse was 0.67 ㎥·s-1 until 1hr and to increase 3 times of it from 1hr after analysis. The roof window were open 100%. Until 1hr of CFD analysis, the temperature in the 30% open of shading screen was 0.9℃ higher than in the none shading screen. From 13:00 O'clock when the air-inlet quantity to increase 3 times, the temperature in case 30% gap of shading screen were decreased compare with the none shading screen, the temperature difference was 0.5℃ at 14:30 O'clock. The temperature on the floor surface in case 30% gap of shading screen were lower with it's height increase, the temperature difference was 8℃ compare with none shading screen. The relative humidity difference were insignificant by the height and gap of shading screen.

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF