건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석 (Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System)

  • 인정현;이율호;강상규;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

가정용 공조기의 응축기 적용 알루미늄 열교환기의 성능 평가 (Performance evaluation of brazed aluminum heat exchangers for a condenser in residential air-conditioning applications)

  • 김만회;김권진
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.44-55
    • /
    • 1998
  • The evaluation of aluminum flat tube and louver fin heat exchangers for a condenser in residential air-conditioning applications has been conducted. A series of tests for two-different brazed aluminum heat exchangers was performed and the results were compared with conventional fin and tube heat exchangers for residential air-conditioning system. Refrigerant charge amount for a window-system air-conditioner with the brazed aluminum condenser is decreased by 35% and the volume and material of heat exchanger can be reduced by 50% compared to the conventional fin and tube heat exchangers.

  • PDF

재생기 및 냉각기가 VM열펌프의 냉방성능에 미치는 영향 (Effects of regenerator and cooler on the cooling performance of a vuilleumier cycle heat pump)

  • 이건태;강병하;유호선;이재헌
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.333-342
    • /
    • 1997
  • An experimental study has been carried out to investigate the effects of the combination of the different wire mesh number in a regenerator and the tube number in a cooler on the cooling performance of a Vuilleumier cycle heat pump. Effects of operating conditions, such as charging pressure, operating speed, and heat input, on the cooling performance are also studied. The experimental results obtained indicate that the cooling performance could be improved with the proper combination of different wire meshes in a regenerator. More tubes in a cooler are desirable for better cooling performance. It is also found that the cooling capacity is enhanced, whereas COP is reduced with an increase in the heater tube temperature and the revolution speed. Both the cooling capacity and COP are incereased with a higher charging pressure.

  • PDF

자동차 공조시스템에서 건조기 일체형 응축기의 성능특성 (Performance Characteristics of Sub-Cooled Hybrid Condenser in Automotive Air-Conditioning System)

  • 김경훈;김석우
    • 한국자동차공학회논문집
    • /
    • 제12권5호
    • /
    • pp.205-210
    • /
    • 2004
  • Sub-cooled hybrid condenser(SCHC) which have been developed through this study is an appliance of integrating a condenser with a receiver dryer, which were previously separated. It is supposed that the development of sub-cooled hybrid condenser will be able to reduce not only weight, size, production process and cost, but also quite improve in capability, which will be of great use for the technological development and research of an air conditioning system whose importance is higher in a car. Through the present study it was found that the developed SCHC increases in the degree of sub-cooling by 10∼100% compared to conventional condenser. The excessive sub-cool has improved the cooling performance by 10%, and that leads to the reduction in evaporator outlet air temperature $1.5^{\circ}C$. Additionally, it is expected that sub-cooled hybrid condenser weights less by 100g than the previous condensers which has equal super heat.

평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기 (Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet)

  • 조진표;김내현
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.

지열원 멀티열펌프 시스템의 용량가변 특성 연구 (Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions)

  • 조찬용;오명석;최종민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

동양최대 규모의 용산역사 에너지절감 설비 채택 추진 장본인 연간 약 6억원의 에너지비용 절감

  • 에너지절약전문기업협회
    • ESCO지
    • /
    • 통권31호
    • /
    • pp.28-29
    • /
    • 2004
  • 이경희 과장은 ''용산민자역사'' 공사에서 에너지절감 설비를 책임지고 수행한 장본인이다. 그가 올해 에너지절약 유공자의 한 사람으로 지난 11월 12일 에너지절약촉진대회에서 산자부 장관상을 받은 것도 이러한 공로를 인정하고 땀방울을 격려하기 위해 그의 동료들이 적극 추천했기 때문이다. 그가 수행한 설비는 빙축열냉방시스템과 고효율 공조장비. 빙축열은 터보냉동기에 비해 연간 4억원의 절감효과를 가지고 있으며 고효율 공조장비는 연간 2억정도의 에너지세이빙효과를 가지고 있다.

  • PDF

올 가스보일러 90만대 넘어설 듯

  • 전국보일러설비협회
    • 보일러설비
    • /
    • 1호통권144호
    • /
    • pp.104-109
    • /
    • 2006
  • 올해도 그리 밝지만은 않을 것으로 예상되는 보일러 시장은 각 보일러업체들의 다양한 사업다각화가 두드러질 것으로 보인다. 겨울 한철 사업으로 여름내내 성수기가 되기만을 기다리던 때와는 달리 냉방사업을 통해 줄어드는 보일러 물량을 채우고 일본과 유럽지역에 호황을 누리고 있는 가스 · 기름온수기를 출시해 사업의 다각화를 꾀할 예정이다. 특히 각 사가 내세우는 거꾸로 타는 기술과 공기 비례제어 기술, 똑바로 타는 기술 등이 한층 업그레이드돼 소비자들을 찾을 것으로 전망된다. 이제는 모두 다 같은 기술과 마케팅 전략이 아닌 각 업체들이 지닌 신기술과 노하우만이 보일러 시장을 공략해 갈 수 있을 것으로 판단된다.

  • PDF

여름철 유리온실의 증발냉각을 위한 설계기준안 연구 (Studies of standard design proposal for evaporative cooling in summer glasshouse)

  • 우영회;이정명;권영삼;남윤일;김형준;송천호;김동억
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1995년도 특강 및 학술논문발표요지
    • /
    • pp.74-77
    • /
    • 1995
  • 냉동기등의 냉방장치에 의한 온실의 기온하강은 주간에 과다한 일사부하로 인하여 경제적으로 불가능하기 때문에 현재 증발냉각법이 주로 이용되고 있다. 그러나 증발냉각법의 구체적인 설계기준안에 대한 국내연구는 전무한 실정이다. 따라서 본 연구는 우리나라 기상여건을 고려하여 증발냉각법을 위한 설계기준안을 제시하고자 하였다. (중략)

  • PDF