• 제목/요약/키워드: 냉방기

검색결과 289건 처리시간 0.031초

An Experimental Study for Manufacturing MPCM Slurry and Its Application to a Cooling System (미립캡슐잠열재 제조 및 축열식 냉방기 적용실험)

  • 이효진;최준규;이재구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제15권5호
    • /
    • pp.352-359
    • /
    • 2003
  • The present study has been conducted for manufacturing MPCM (microencapsulated phase change material) slurry with in-situ polymerization and proving their applicabilities for tooling system. The surface of MPCM is composed of melamine, while tetradecane, paraffin wax, is centered in the MPCM. The produced capsules are observed by the optical microscope and SEM for superficial shapes. Their thermal properties are measured by DSC. Their size distributions are observed by FA particle analyzer. A narrow size distribution from 1 to 10 ${\mu}{\textrm}{m}$ with 5 ${\mu}{\textrm}{m}$ of average diameter was observed. Melting temperature was 6.7$^{\circ}C$. The durability of MPCM was tested with various types of pump such as centrifugal, peristaltic, and mono pumps. During 10000 cycles the fraction of broken capsules was smaller than 6% for the centrifugal and peristaltic pumps, while bigger value of 8% for the mono pump. A cooling system, which adopted MPCM slurry as a media for transporting cold thermal energy, was designed to investigate the performance of the MPCM. The discharging times of 10 and 20 wt% MPCM slurry were lasted up to 105 and 285 minutes longer, respectively, than the water cooling system.

Comparison of Outside Design Weather Data for Greenhouse Heating and Cooling (온실의 냉.난방 설계용 기상자료의 비교분석)

  • 남상운
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 한국생물환경조절학회 2000년도 학술발표논문집
    • /
    • pp.94-97
    • /
    • 2000
  • 온실의 환경설계 중에서 가장 기본이 되는 냉ㆍ난방 설비용량의 결정을 위하여는 설계외기온(냉ㆍ난방설계), 외기의 습구온도 및 수평면 일사량(냉방설계)과 같은 기상자료가 필요하다. 시설재배에 있어서 환경설비의 용량 부족은 혹한기 또는 혹서기에 작물의 생육에 치명적인 영향을 미칠 수 있다. 또한 설비용량의 과대설계는 설치비 면에서 비경제적일 뿐만 아니라 에너지의 효율적 이용 측면에서도 불리하므로 적정 설비용량의 결정은 매우 중요하고, 따라서 설계용 기상자료의 선택은 매우 신중을 기하여야 한다. (중략)

  • PDF

Study on Improvement in Cooled Air Defense Gun System Including Closed Drum Basket (비개방형 포탑드럼바스켓을 가진 대공포체계의 냉방장치개선 연구)

  • Hwang, Boo Il;Lee, Dong Hui;Kim, Chi Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제39권1호
    • /
    • pp.109-113
    • /
    • 2015
  • Combat vehicles need an air-conditioning unit, although new combat systems tend to use an integrated system for heating, cooling, and ventilating. The specifications of an air-conditioning unit depend on the combat vehicle's purpose. It is difficult to send cooling air from the air-conditioning unit to a gun turret through the drum basket because the gun turret rotates and consists of a closed anti-aircraft shell magazine. In this study, we considered an air-conditioning unit for armored combat vehicle based on the special requirements and military specifications. We evaluated the performance of the air-conditioning unit despite the rotating gun turret through analysis and tests in terms of flow improvement compared to the previous model.

Thermodynamic Performance Analysis of Heat Pump Using Thermoelectric Semiconductor (열전반도체를 이용한 열펌프의 열역학적 성능 해석)

  • 박영무
    • Journal of Energy Engineering
    • /
    • 제2권1호
    • /
    • pp.95-103
    • /
    • 1993
  • A conceptual thermoelectric heat pump(cooling mode) of small capacity is designed. Its performance is investigated through parametric analysis. COP and cooling capacity decease as the ambient temperature increases with ${\mu}$, J, T$\sub$wi/, fixed. To design a system of fixed capacity comes to calculate ${\mu}$ and J when T$\sub$wi/, and T$\sub$a/ are given. As v is fixed by semi-conductor manufacturers, optimum combination of n and I should be searched for ν. Optimum current could be calculated using ${\mu}$-J curve and optimum value of ${\mu}$. COR$\sub$R/ increases as water flow rate increases and T$\sub$a/ decreases. The effect of heat transfer coefficient at hot(heat releasing) side is more significant than that at cold(heat absorbing) side.

  • PDF

A Study on the Performance Characteristics of Water Heat Source Heat Pump System using CO2 Refrigerant (이산화탄소를 사용한 수열원 히트펌프 시스템의 성능 특성에 관한 실험적 연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제12권8호
    • /
    • pp.3366-3373
    • /
    • 2011
  • In this study, performance characteristics of a water source heat pump system using $CO_2$ as a refrigerant are investigated experimentally. Cooling and heating capacities and COP of the system are analyzed for various system performance variables such as refrigerant charge, expansion valve opening, compressor frequency and internal heat exchanger. Results show that optimum amount of refrigerant charge and expansion valve opening exists at maximum point of COP curve, and cooling capacity increases but COP decreases with the increase of compressor frequency. When the internal heat exchanger is installed, cooling capacity increases about 4.0% whereas heating capacity decreases about 0.89% compared to the case without internal heat exchanger.

지혜 깊어지는 건강_50대를 지켜라: 설사와 복통 때문에 여름이 괴롭다

  • Choe, Dong-Hyeon
    • 건강소식
    • /
    • 제35권7호
    • /
    • pp.18-20
    • /
    • 2011
  • 여름은 무더위와 장마 같은 변덕스런 날씨 이외에도, 실내의 지나친 에어컨 냉방이나 주변에 인공적인 먹을거리들이 넘쳐나는 계절로 건강을 지켜내기란 더욱 어렵다. 특히 한집안의 가장으로서, 사회의 주축으로서 왕성한 활동기에 있는 50대는 슬기롭게 자신의 건강을 살피는 지혜가 필요하다. 특히 여름철에 흔히 나타나는 복통과 설사의 원인과 예방책을 알아본다면 건강한 여름을 날 수 있을 것이다.

  • PDF

전기유동유체(ERF)를 이용한 지능구조물 시스템의 구성 및 응용

  • 최승복;박용군
    • Journal of KSNVE
    • /
    • 제5권3호
    • /
    • pp.275-283
    • /
    • 1995
  • 본 글에서는 지능구조물의 개념설명과 더불어 ERF의 특성, ERF를 함유란 함유 한 지능구조물 시스템의 구성, 동적 모델링과 진동제어 그리고 그 응용성에 관한 연구 현황과 방향에 대해 살펴보았다. 설명한 바와 같이 지능구조물은 새로운 차원의 신생 하는 첨단분야로서, 소음 및 진동에 관련된 무한한 잠재력과 다양한 응용성으로 미루 어 볼때 아주 매력적인 연구 분야이다. 그러나, 여러 응용 시스템의 상품화 단계로의 도약에 있어서 각 시스템 구성 요소 분야별 해결해야할 연구 사항들이 있다. 먼저, 액추에이팅을 수행하는 ERF 자체의 내구성 문제로서 고온에서 ERF의 효과 하락과 장시간 사용시 ERF에 의한 마멸, 고체 입자의 침전에 의한 초기 상태 불안정 등이 있다. 아울러 기존의 장치의 성능을 능가하기 위해 보다 큰 효과를 나타내는 새로운 차원의 ERF개발이 요구된다. 그리고 센서기술 분야에서는 호스트 재료에 보다 쉽게 결합이 되고 여러가지 형태의 요구조건을 만족시킬 수 있으며 외부 환경조건에 강건 하고 다양한 센서 개발이 요구된다. 또한, 보다 일번적인 동적 모델링을 통해 적용 시스템에 적합하고 강건한 제어기에 대한 연구가 진행되어야 한다. 마지막으로 능동 제어기를 실제로 구현하기 위한 호스트 재료 각 요소마다 센서의 설치, 페회로 피드백 시스템 장착, 상호간의 인터페이스 등의 기술 발전이 요구되며, 아울러 보다 효율적 인 시스템의 성능 특성을 실현할 수 있는 호스트 재료와 기계 메카니즘이 필요로 된다. 이상의 설명에서 알 수 있듯이 지능구조물에 대한 연구는 어느 한 분야에서만 아니라 기계, 전기전자, 토목, 물리, 재료과학 등 통합형식에 의한 접근 방향으로 추진되어야 할 것이다.서 세탁기의 진동 소음을 저감시키기 위해 진동 소음원에 대해 논술하고, 진동해석을 위해 컴퓨터 시뮬레이션 결과를 이용한 저진동 기술 개발에 대하여 기술하고자 한다.rotary piston)식 압축기는 약 20여년 전 부터 냉방용 압축기에서부터 널리 쓰이게 되었다. 약 10여년전부터 상용화 된 스크롤(scroll) 형 압축기도 현재 상대적으로 용량이 큰 가정용 냉방기를 중심으로 많이 쓰이고 있다. 스크류형 압축기는 보통 중대형 상업용에 주로 쓰인다. 해결하려 하였고, 수치해석은 피스톤의 운동을 배제한 단순화한 흡배기계의 정상상태 유동해석이 주를 이루어왔다. Taghaui and Dupont 등[5]은 KIVA코드를 사용하여 흡기포트와 연소실 그리고 밸브의 움직임을 동시에 고려한 수치해석을 도입하였다. 하지만 이들이 밸브의 운동을 고려하기 위해 사용한 이동격자는 격자점은 시간에 따라 변화하지만 그 격자의 수가 일정하게 유지되어 있어서 밸브의 완전개폐를 해석할 수가 없다. 강희정[6]은 단일 실린더와 단일 배기밸브를 갖는 문제로 단순화하여 피스톤과 밸브의 움직임을 고려하므로써 배기행정 후 소음이 어떻게 전파해 나가는가를 연구하였다. 본 연구에서도 최소밸브간격과 최대밸브간격 사이에서만 계산이 가능하나 흡기의 경우는 밸브가 닫힐 때 생기는 압력파가 중요하므로 실린더와 밸브사이에 벽면조건을 주어 밸브의 개폐를 모사하였다.술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS.

  • PDF

Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF