Analysis of Heating and Cooling Energy Consumption in Rental and Sales Apartments in Busan (부산시 임대아파트 및 분양아파트의 냉난방에너지 소비량 분석)

  • Lee, Kyung-Hee;Lee, Jun-Gi
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2021
  • This study analyzed the energy consumption differences between rental and owner owned (purchased) apartments in Busan, South Korea during the cooling and heating seasons. Analysis revealed that the average electricity consumed for cooling was 2.5 kWh/m2·yr for rental apartments and 2.3 kWh/m2·yr for purchased apartments, a difference of 0.2 kWh/m2·yr. The average electrical heating energy consumption was 3.3 kWh/m2·yr for rental apartments and 2.2 kWh/m2·yr for purchased apartments, a difference of 1.1 kWh/m2·yr. It was estimated that the use of electric blankets and heaters was higher in rental apartments than purchased apartments resulting in higher electrical heating energy consumption. The average gas heating energy consumption was 7.0 kWh/m2·month for rental apartments and 6.8 kWh/m2·month for purchased apartments. When electricity and gas usage was combined for heating, the average total heating energy consumption was 10.3 kWh/m2·month for rental apartments and 9.0 kWh/m2·month for purchased apartments. This indicates that rental apartments consume 1.3 kWh/m2·month more energy than purchased apartments during heating season. Overall, rental apartments consume more energy than purchased apartments during both the cooling and heating seasons.

Indoor Temperature Analysis by Point According to Facility Operation of IoT-based Vertical Smart Farm (IoT 기반 수직형 스마트 팜의 설비운영에 따른 지점별 실내온도분석)

  • Kim, Handon;Jung, Mincheol;Oh, Donggeun;Cho, Hyunsang;Choi, Seun;Jang, Hyounseung;Kim, Jimin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.98-105
    • /
    • 2022
  • It is essential for vertical smart farms that artificially grow crops in an enclosed space to properly utilize air environment facilities to create an appropriate growth environment. However, domestic vertical smart farm companies are creating a growing environment by relying on empirical data rather than systematic methods. Using IoT to create a growing environment based on systematic and precise monitoring can increase crop production yield and maximize profitability. This study aims to construct a monitoring system using IoT and to analyze the cause by demonstrating the imbalance of temperature environment, which is a significant factor in crop cultivation. 1) The horizontal temperature distribution of the multi-layer shelf was measured with different operating methods of LED and air conditioner. As a result, there was a temperature difference of "up to 1.7℃" between the sensors. 2) As a result of measuring the vertical temperature distribution, the temperature difference was "up to 6.3℃". In order to reduce this temperature gap, a strategy for proper arrangement and operation of air conditioning equipment is required.

Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter (재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발)

  • Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.77-84
    • /
    • 2011
  • Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from $27^{\circ}C$ to $39^{\circ}C$ by the air conditioner converted to a heat pump system with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, and cooled from $20^{\circ}C$ to $15^{\circ}C$ by the converted system with the ambient temperature variation of $20^{\circ}C{\sim}35^{\circ}C$. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, respectively, whereas the cooling COP decreased from 3.1 to 2.1with the increase of the ambient temperature from $20^{\circ}C$ to $35^{\circ}C$.

A Study on Integrated Air-conditioning System for Electric Vehicle Based 1-ton Class Commercial Vehicle (전기차 기반의 1톤급 상용차용 통합공조 시스템에 관한 연구)

  • Baek, Soo-Whang;Kim, Chul-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.361-368
    • /
    • 2019
  • This paper is a study on integrated air-conditioning system for 1-ton class commercial vehicle based on electric vehicle. In the case of an electric commercial vehicle, since the opening and closing of the door is frequently performed in order to get in and out of the cargo, the heat loss largely occurs. Therefore, the heating and cooling load is required to be larger than the electric vehicle. As a result, the energy consumed by the heating and cooling system is larger than the passenger electric car in order to satisfy the heat comfort required by passengers. In order to overcome these disadvantages, we performed research using an efficient integrated air conditioning system. Finally, the design and analysis of a heat pump system for heating and a electrical compressor for cooling need to be proceed to develop a high-efficiency air conditioning system for improving the commerciality of 1 ton-class electric trucks and expanding the industrial ecosystem in the electric truck sector.

Effects of Several Cooling Methods and Cool Water Hose Bed Culture on Growth and Microclimate in Summer Season Cultivation of Narrowhead Goldenray 'Ligularia stenocephaia' (곤달비 여름재배 시 냉각방법과 냉수호스베드재배가 생육 및 미기상에 미치는 영향)

  • Kim, Ki-Deog;Lee, Eung-Ho;Kim, Won-Bae;Lee, Jun-Gu;Yoo, Dong-Lim;Kwon, Young-Seok;Lee, Jong-Nam;Jang, Suk-Woo;Hong, Soon-Choon
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2011
  • This study was carried out to investigate the effects of several cooling methods such as water hose cooling, mist, fog and control on growth and microclimate, and to develop a simple nutriculture bed for production of fresh leaves of narrowhead goldenaray 'Ligularia stenocephala'. When the root-zone was cooled with 240 L/hr flow rate of $13^{\circ}C$ ground water using water hose, the temperature was lowered approximately by 2 to $3^{\circ}C$ than that of control. The growth of narrowhead goldenaray were favorable in the water hose cooling compared with the other cooling methods. Nutrient culture system having part cooling effect around plant canopy was developed. The system was composed of 15 cm diameter of water hose on side wall of beds, cooling hose, and expanded rice hull media as organic substrate. When cool water which the temperature changed in the range of 14 to $22^{\circ}C$ diurnally with 240 L/hr of flow rate through water hose, the air temperature around canopy and root-zone temperature were dropped by $0.5^{\circ}C$ and $3^{\circ}C$ compared with that of conventional styrofoam bed, respectively. These results showed that newly devised bed system using water hose was simple and economical for the production of high quality narrowhead goldenaray leaves. This system might be practically used both at summer and winter season for the cultivation of narrow head goldenaray by part cooling or heating around root-zone and plant canopy.

Numerical Study of Concentration Characteristics of Linear Fresnel Reflector System (선형 프레넬 반사판 시스템의 집광 특성에 대한 수치해석 연구)

  • Lee, Hyun Jin;Kim, Jong Kyu;Lee, Sang Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.927-934
    • /
    • 2015
  • In this study, we numerically investigated the concentration characteristics of a linear Fresnel reflector system that can drive a solar thermal absorption refrigeration system to be installed in Saudi Arabia. Using an optical modeling program based on the Monte Carlo ray-tracing method, we simulated the concentrated solar flux, concentration efficiency, and concentrated solar energy on four representative days of the year - the vernal equinox, summer solstice, autumnal equinox, and winter solstice. Except the winter solstice, the concentrations were approximately steady from 9 AM to 15 PM, and the concentration efficiencies exceed 70%. Moreover, the maximum solar flux around the solar receiver center changes only within the range of $13.0{\sim}14.6kW/m^2$. When we investigated the effects of the receiver installation height, reflector width, and reflector gap, the optimal receiver installation height was found to be 5 m. A smaller reflector width had a greater concentration efficiency. However, the design of the reflector width should be based on the capacity of the refrigeration system because it dominantly affects the concentrated solar energy. The present study was an essential prerequisite for thermal analyses of the solar receiver. Thus, an optical-thermal integration study in the future will assist with the performance prediction and design of the entire system.

Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater (태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구)

  • Choi, Hwi-Ung;Kim, Young-Bok;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.47-57
    • /
    • 2017
  • Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

Optimum Management of Greenhouse Environment by the Shading Coat and Two-fluid Fogging System in Summer Season (차광제와 이류체 포그시스템을 이용한 고온기 시설내 환경관리)

  • Kim, Sung Eun;Lee, Jae Eun;Lee, Sang Don;Kim, Hak Sun;Chun, Hee;Jeong, Woo Ri;Lee, Moon Haeng;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.24 no.1
    • /
    • pp.34-38
    • /
    • 2015
  • This research was conducted to establish efficient methods to overcome high temperature and low humidity with light selective shading agent and two-fluid fogging system in greenhouses in hot season. There were four experimental treatments; not treated (Non), fogging by two-fluid fogging system (Fog), spraying onto the greenhouse surface with shading coating agent (Coat), and using fogging and coating together (F&C). The amount of solar radiation entered into the greenhouses was higher in Non, and then Fog, Coat, and F&C in descending order. Fog was more efficient to lower the air temperature and also raise relative humidity than Coat treatment. The crop temperature was about $6^{\circ}C$ higher in Control than the other treatments. F&C revealed as the most efficient method to control the environment inside the greenhouse, but fogging system seemed to be more economic. In stand-alone greenhouses spraying coating agent may be the appropriate choice because of their structural limitations, mainly eave height.

Measurement of physiological response and estimation of subjective sensation with cool biz (쿨비즈 복장에 의한 생리적 반응 측정과 주관적 감각평가)

  • Gang, Nu-Ri;Lee, Ji-Yeon;Na, Yeong-Ju
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.236-238
    • /
    • 2009
  • 에너지 절약차원에서 냉방을 줄여 지구온난화 방지에 일조하고자 여름철에 가벼운 차림의 의복을 권장하는 쿨비즈 캠페인이 시작되었으나 이의 정량적인 효과를 분석하는 연구가 미흡하였다. 본 연구에서는 여름철 온실가스 줄이기 및 직장인 등의 건강증진 등을 위하여 기후복장 적응형에 대한 범국민 인식 및 실천 필요를 바탕으로, 실험을 통해 쿨비즈에 의한 생리적 반응 측정 및 주관적 감각평가를 실시하였다. 1 차실험은 두 복장(전통의복,기후의복)의 피부온 측정실험으로, 환경온 25, $27^{\circ}C$, 상대습도 50% RH 에서 20 대 성인남성 4 명을 대상으로 실험을 하였다. 피험자는 심신을 안정할 수 있도록 30 분간의 안정기를 가진 후에 60 분 동안 실험을 하였으며, 사무실 내 작업환경과 같은 분위기 조성을 위해 편안하게 의자에 앉아 가벼운 대화나 컴퓨터 워드작업 및 설문을 응할 수 있도록 피험자 앞 책상 위에는 노트북을 설치해 두었고, 실험 진행기간 동안 피부온, 직장온, 습도, 발한량, 열화상 카메라, 온열감, 습윤감, 쾌적감 등과 같은 주관적 감각을 측정하였다. 2 차 실험은 동일 피부온 발현하는 환경온 찾기로 기준온도($27^{\circ}C$)에서 전통복장을 입고 온도를 점진적으로 하강시키면서 $27^{\circ}C$ 기후 복장을 입은 상태의 피부온도와 동일해지는 실내온도를 측정한다. 착의 형태에 따른 피부온도 변화에서 환경온도 $25^{\circ}C$ 전통의복 기후의복에 의한 피부온도의 차이는 전통의복이 최소 0.3~최대 $1.6^{\circ}C$ 더 높게 나타났으며, 환경온도 $27^{\circ}C$에서 전통의복 기후의복에 의한 피부온도의 차이는 대체적으로 전통의복이 최소 0.4~최대 $1.0^{\circ}C$ 더 높게 나타났다. 주관적 감각평가에서도 기후의복보다 전통의복에서 온열감 습윤감 불쾌감이 더 높은 경향을 보였다. 주관적 감각으로는 $25^{\circ}C$ 전통의복과 $27^{\circ}C$ 기후의복에서 중립적인 느낌을 나타냈다.

  • PDF

Characterization of a new variety "Backryeon" developed by crossing in Tricholoma giganteum (왕송이(Tricholoma giganteum) 신품종 '백련'의 특성)

  • Jang, Kab-Yeul;Kong, Won-Sik;Yoo, Young-Bok;Lee, Kang-Hyo;Jhune, Chang-Sung;Lee, Jung-Hoon;Sung, Jae-Mo
    • Journal of Mushroom
    • /
    • v.7 no.4
    • /
    • pp.187-192
    • /
    • 2009
  • Tricholoma giganteum, belongs to Tricholomataceae of Tricholoma, is also well-known as the medicinal mushroom in Taiwan. "Backryon" was the first variety developed by intra-specific crossing in Korea. It was improved with hybridization between monokaryotic strain derived from MKACC50852 and MKACC 50853. The optimum temperature of mycelial growth and fruiting body development were $25{\sim}30^{\circ}C$ and $20{\sim}25^{\circ}C$, respectively. The color of fruitingbody was pure white and cap type was umbrella. It suggested that 'Backryon' was new commercial variety for small-sized cultivator during the summer season.

  • PDF