• Title/Summary/Keyword: 냉매 압축기

Search Result 157, Processing Time 0.023 seconds

A Study on Performance Improvement of Heat Pump Adopting the Hot Gas Bypass Method (고온냉매 우회방법을 적용한 열펌프의 성능 개선 연구)

  • Kang, Shin-Hyung;Byun, Ju-Suk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.235-242
    • /
    • 2006
  • This study experimentally investigates the performance improvement of the heat pump by adopting the hot gas bypass method and using the internal heat exchanger according to the automatic defrost test conditions of ISO 5151 This study compares the hot gas bypass method with the time step method, and investigates effect on outdoor coil fan speed when the hot gas of compressor outlet enter outdoor coil inlet after the frost formation. The tests were made for the fan speeds of the outdoor coil controlled at 90, 60 and 30% of the normal speed together with the case of the stationary fan. The performance of the heat pump is evaluated by variables such as COP, heat capacity, and the average COP during the 210 minutes heating mode. Results show that average COP of the hot gas bypass mettled is $2.2{\sim}6%$ higher than that of the time step method. When the outdoor coil fan speed is 60% (780 rpm) of the normal speed, it shows the best COP and heating capacity.

Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants (암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측)

  • Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids for 2-stage compression and 1-stage expansion refrigeration system. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of 2-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of 2-stage compression and 1-stage expansion refrigeration system using natural refrigerants have an effect on COP of this system. The COP of natural refrigerants was higher than the COP of freon R22 in this study, so points to be considered are the security, the attached facilities for natural refrigerants than COP.

일반 산업용 공기압축기의 원리와 구조

  • 최철환
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.11
    • /
    • pp.31-35
    • /
    • 2002
  • 금번 특집호중 앞서 소개된 각종 냉매 또는 가스압축기의 소개를 통해 압축기의 종류 및 작동원리에 대한 내용은 이미 많이 소개되었을 것으로 생각됩니다. 따라서 실제 공기압축기를 사용하고 선정하는데 필요한 기본원리와 구조에 대해 간략히 소개하고자 합니다. 공기의 운동이나 공기 압축을 의미하는 Pneumetic 이라는 말은 고대 그리이스어의 "Pneuma"에서 유래 되었으며 호흡, 바람을 의미했고, 철학에서는 정신(영)을 의미했다. 공기압축기는 전기모터나 내연기관(원동기) 또는 터어빈 등의 동력장치로부터 동력을 전달받아 공기에 압축일을 가함으로써 공기를 압축시켜 압력을 높여주는 기계로서 오늘날 산업전반에 걸쳐 널리 사용되고 있고 이중 중소형 공기압축기의 대표 기종인 소형왕복동식공기압축기와 중형스크류식공기압축기의 원리와 구조에 대해 소개하고자 한다. 소개하고자 한다.

  • PDF

Simulation on the performance of an automobile climate control system with Internal heat exchanger and TXV (내부열교환기와 TXV를 적용한 자동차용 공조시스템의 성능에 관한 수치적 연구)

  • Park, Cha-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.31-36
    • /
    • 2021
  • Recently, automobile air conditioning systems have applied an alternative refrigerant that can replace the high GWP refrigerant R134a due to the global warming problem. This study simulated the performance of an automobile climate control system with an internal heat exchanger and TXV. Refrigerant R1234yf was applied as the working fluid. Amesim, a commercial software program, was used to model the main components of the compressor, condenser, TXV, evaporator, and internal heat exchanger. As the outside temperature increased from 30℃ to 40℃, the cooling capacity of the system decreased by 3.1%, and the power consumption of the compressor increased by 17.1%. In addition, The performance characteristics of the refrigeration cycle were simulated by increasing the fin pitch of the condenser from 0.8 mm to 1.4 mm. When the fin pitch was larger than 1.0 mm, the condenser capacity decreased, and the system COP was lowered by 5.9%. When the fin pitch of the condenser was 0.8 mm, which was smaller than 1.0 mm, there was no significant change in the system performance. Hence, the optimal performance was observed at a fin pitch of 1.0 mm.

Finite Element Analysis of Piston Slap Phenomenon in Reciprocating Compressors Considering Coolant Circulation (냉매순환을 고려한 왕복동형 압축기의 피스톤 슬랩현상에 대한 유한요소 해석)

  • Moon, Seung-Ju;Cho, Jin-Rae;Kim, Hyun-Ok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1087-1094
    • /
    • 2003
  • The piston slap phenomenon occurs when the piston collides with the internal wall of the cylinder. Impact force caused by piston slap is one of the major mechanical noise sources in reciprocating compressors. In response to public demand, strict regulations are increasingly being imposed on the allowable noise level which is caused mostly by household electric appliances. In this paper, forces acting on piston by considering the dynamic behavior of suction and discharge valves are analytically calculated and the piston slap caused by the piston secondary motion is investigated by the finite element method.

Performance analysis of the reciprocating compressor with hydrocarbon refrigerant mixtures, R290/R600a (탄화수소계(R290/R600a) 혼합냉매를 적용한 왕복동형 압축기 성능 해석)

  • 김종헌;정연구;박경우;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.270-280
    • /
    • 1999
  • A performance analysis simulation program that can be applied to a hermetic reciprocating compressor with various refrigerants has been developed. For the numerical analysis, the passage of refrigerant in compressor is subdivided into control volumes. Instead of the ideal gas assumption, CSD equation of state is applied to calculate the thermodynamic properties of refrigerants. To verify the validity of developed program, the result has been compared with the experimental data served by the compressor supplier. The performance of each refrigerant and the possibility of direct application are estimated by applying R12, 134a, R290, R600a and R290/R600a mixture to an existing compressor. Also, parametric study for various crank rotating speeds and the mole fractions of refrigerant has been performed.

  • PDF

Study on the Performance Characteristics of the Roof Mounted Electrical Air Conditioning System Using Inverter Scroll Compressor (인버터 스크롤 압축기를 적용한 루프형 전동공조시스템의 냉방성능특성에 관한 연구)

  • Lee, Moo-Yeon;Won, Jong-Phil;Lee, Dong-Yeon;Cho, Chung-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4308-4313
    • /
    • 2011
  • The objective of this study is to investigate the cooling performance of the roof mounted air-conditioning system using electric driven scroll compressor for zero emission vehicles. This air conditioner with air source was used R-134a as a refrigerant and tested under various operating conditions such as refrigerant charge amount and indoor temperature, and compressor frequencies. Experimental results revealed that at all tested compressor frequencies, heat transfer rate of the evaporator increased and the cooling COP increased with the indoor temperature. In addition, the heat transfer rate of the evaporator was over 25.0kW sufficient for the cooling loads of an electric bus.

The application of hydrocarbon refrigerants in a hermetic reciprocating compressor for low back pressure conditions (저온용 밀폐형 왕복동 압축기에서 탄화수소계 냉매 적용)

  • 김기문;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.683-694
    • /
    • 1998
  • The application of hydrocarbon refrigerants in a hermetic reciprocating compressor for refrigerator is investigated. The selected refrigerants are isobutane(R600a), propane(R290), R12, binary mixture of R600a/R290, and OS-21CII. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to the traditional refrigerant(R12). The results show that hydrocarbon refrigerants(HC-Blend, OS-21C II) are very good alternatives in the refrigeration system for R12.

  • PDF

The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for high back pressure conditions (고온용 밀폐형 왕복동 압축기에서 탄화수소계 혼합냉매 적용)

  • 김기문;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.262-269
    • /
    • 1999
  • The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for dehumidifier is investigated. The selected refrigerants are R12, R134a, HC-Blend (R290/R600a), CX(R152a/R600a) and OS-l2a. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to traditional refrigerant(R12) and R134a. The results show that hydrocarbon refrigerant mixtures(HC-Blend, CX and OS-l2a) are very good alternatives in the refrigeration system for R12 and R134a.

  • PDF

Cooling Performance Characteristics of High-Performance Heat Pump with VI Cycle Using Re-Cooler (재냉기를 이용한 고성능 VI(Vapor Injection)사이클 열펌프의 냉방 성능특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.592-598
    • /
    • 2015
  • In this study, we experimentally investigate the performance characteristics of a high-performance summer-cooling heat pump for an R410A by applying an air-cooled-type vapor-injection (VI) cycle. The devices used for the experiment consist of a VI compressor, condenser, oil separator, plate-type heat-exchanger, economizer, evaporator, and re-cooler. The experimental conditions employed for the cooling performance were divided into three cycles. First, in Cycle A, we apply a VI cycle and with no heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant in the re-cooler. For Cycle B, there is heat exchange, and for Cycle C, there is neither a VI cycle nor heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant. From the analysis results, we observe that the performance was highest in the VI cycle with heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant (Cycle B), while it was lowest in Cycle C without application of the VI cycle. Moreover, the cooling coefficient of Performance ($COP_C$) averaged 3.5 in Cycle B, which was 8.6% higher than the corresponding value in Cycle A, and 33% higher than that in Cycle C.