• Title/Summary/Keyword: 냉동용량

Search Result 78, Processing Time 0.042 seconds

Scheme for Measuring Refrigeration Capacity of Cryopump Refrigerator (크라이오 펌프 냉동기 냉각용량 측정방안)

  • In, S.R.;Cho, H.S.;Jeong, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.243-251
    • /
    • 2011
  • An apparatus for measuring the refrigeration capacity of cryopump refrigerators including the pulse tube type being developed domestically and the GM type has been designed, manufactured, and tested. The refrigeration capacity of a commercial refrigerator was evaluated for confirming the measurement procedure and the operation performance of the apparatus. The measured 2-D refrigeration capacity chart showed the intrinsic characteristics of the refrigerator model used in the experiment. In this paper, design specifications and test results of the refrigeration capacity measurement system is reported and discussed.

Design of Capillary Tube for a Refrigeration Systems (냉동시스템의 모세관 설계)

  • 정백영;함성훈;김태진
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.966-972
    • /
    • 1993
  • 모세관(capillary tube)은 일정면적식 팽창기구의 대표적인 것으로서 사용역사가 길고, 신뢰성이 높고, 가격이 저럼하므로 냉동공조시스템의 냉매제어장치로 매우 많이 사용되고 있다. 이것은 냉동시스템의 응축기와 증발기 사이에서 유입하는 고압의 액상냉매를 증발기에서 증발하기 쉬운 증발압력까지 압력을 강하시키는 감압팽창작용과 증발기의 증발 용량에 적당한 냉매 질량유량을 공급하는 역할 (이 작용은 냉동시스템의 용량과 작동범위를 결정하는데 매우 중요하다.)을 한다. 이 글에서는 모세관의 형상, 재질 및 그장 . 단점과 작동원리, 내부 유동현상 등 일반적인 사항에 관하여 기술한다.

  • PDF

HVAC & Refrigeration System for Work Barge Vessel (WORK BARGE 선의 냉동.공조 SYSTEM)

  • Nam, Im-Woo;Jung, Jae-Chun;Kim, Bong-Je
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.583-590
    • /
    • 2008
  • 최근 작업자 숙소 및 이송용 외에 작업용으로 사용 가능한 Barge선의 일종인 Accommodation Work Barge 선의 건조량이 증가 추세인 바 현재 중국에서 건조 중인 해당 선박의 HVAC & Refrigeration system에 대하여 정리하였다. 본 시스템은 R404A Direct expansion 냉각방식 (직접팽창방식)이 적용되었으며 HVAC system 중 Air conditioning 부분에 대해서는 선박의 각 Deck 기준으로 Zoning 하여 개별적인 Air handling unit와 Condensing unit를 구성하였으며 (각 unit의 용량은 필요용량의 100%), 냉동 창고의 Refrigeration system은 해당 격실 (육고, 어고, 야채고)에 각각 Unit cooler를 설치하고, Condensing unit를 기계실에 설치하였다. 장비는 전체 용량 100%에 대하여 항시 운전하는 100% 용량의 장비와 비상시에 운전하는 100% 용량의 예비 장비로 구성된다. 냉동 창고에 인접한 Dry provision store는 냉동 창고와는 별개로 중앙 공조기로부터의 냉각 공기를 이용하여 Spot cooling하였다. 본 System의 구성에 대한 장점 및 단점은 아래와 같다. 1. Air conditioning system이 각 Zone에 대하여 구성되므로 각 Zone에 대하여 제어가 가능하다. 2. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 냉매 배관의 길이가 짧다. 3. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 실내의 Maintenance space 상에 여유가 없다.

  • PDF

국산 맥동관형 크라이오 펌프 시제품 종합특성평가 및 성능개선안

  • In, Sang-Ryeol;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.248-248
    • /
    • 2013
  • 저소음, 저진동이 장점인 맥동관형 냉동기 및 이를 이용한 크라이오 펌프를 국산화하는 연구개발사업이 상당히 진전되어 첫 번째 시제품을 완성했다. 3개월 여에 걸쳐 냉동기 냉동능력, 진동 및 펌프 냉각시간을 포함해서 질소, 수소 또는 알고에 대한 펌프 배기속도, 배기용량, 최대유량, 교차값, 알곤회복시간 등 규격, 비규격을 통틀어 모든 평가항목을 망라하는 펌프 배기 성능시험을 완료했다. 성능평가결과에 나타난 시제품의 장단점을 분석하여 보완 및 개선점을 찾고 이를 완제품 제작에 반영하려고 한다. 내경 14인치인 크라이오 펌프 시제품의 질소 배기속도는 목표치를 30% 정도 상화하여 4,600 L/s가 나왔고 배기용량은 약 45만 $mbar{\cdot}L$에 달했으며 교차값은 2,200 $mbar{\cdot}L$로 측정되었다. $5{\times}10^{-8}$ mbar 기준 알곤 회복시간은 2분 정도로 5분 이내라는 기준을 만족했다. 한편 20 K까지 펌프 냉각시간이 135분이므로 15분 이상 단축이 필요한데 이는 열차폐 특히 배플의 열적설계를 개선함으로써해결하려고 한다. 그리고 수소에 대한 배기성능 개선을 위해 활성탄 어레이의 제작공정을 표준화할 필요가 있다.

  • PDF

기술현황분석 - 초전도 케이블 액체질소 냉각용 극저온 냉동기 기술

  • Park, Seong-Je;Hong, Yong-Ju;Go, Jun-Seok;Kim, Hyo-Bong
    • 기계와재료
    • /
    • v.25 no.3
    • /
    • pp.106-119
    • /
    • 2013
  • 초전도 전력기기는 초전도체를 극저온으로 냉각, 전기저항이 없는 초전도 고유의 현상을 이용하여 중전 전력기기의 열손실 저감, 소형화 및 신뢰성 향상을 가능케 하며, 최근에는 고온 초전도 재료의 기술 수준이 향상되어 초전도 응용 영역이 확대되고 있다. 초전도 케이블을 포함한 초전도 전력기기는 운전 조건인 극저온 환경($-150^{\circ}C$이하)를 조성하기 위해 극저온 냉동기 기술이 핵심적인 기술이다. 극저온 냉동기는 냉각 용량에 따라 소용량(수~수십 W), 중용량(수백 W~수 kW), 대용량(수십 kW 이상)으로 구분할 수 있으며, 초전도 전력기기용 냉각시스템은 주로 중용량 극저온 냉동기의 활용도가 매우 높다. 현재 상용화된 극저온 냉동기를 분석하면, 중용량 극저온 냉동기로는 스터링 극저온 냉동기가 가장 적합하다. 따라서 본 고에서는 중용량 스터링 극저온 냉동기 기술에 대한 개발 현황을 살펴보도록 한다.

  • PDF

A Numerical Model of Thermoacoustic Refrigerators (열음향냉동기의 수치적 모델)

  • 채왕병;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.110-119
    • /
    • 1996
  • A numerical of thermoacoustic refrigerators has been developed. Effects of heat transfer and viscosity on pressure and velocity distributions in resonators and heat exchangers were considered. Predictions of cooling capacity and COP agreed well with previous experimental results. Effects of important design parameters, such as pressure ratio, spacing between the plates in the stack and stack length, on the performance of thermoacoustic refrigerators were shown.

  • PDF

Research of Cryogenic Helium Refrigerator System for SQUID (SQUID 냉각장치용 극저온 시스템 개발)

  • Lee, Kum-Bae;Baek, Il-Hyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.18 no.2
    • /
    • pp.121-129
    • /
    • 1989
  • 헬륨을 이용한 극저온 냉동기는 압축기(compressor)을 통하여 압력을 10-20 기압 정도로 높혀준후 여러 단계의 열교환기(heat exchanger)를 통하여 상전위온도(maximum inversion temperature) 이하로 떨어뜨린후 Joule-Thomson 밸브를 통하면 4K까지 온도가 떨어진다. 이때 압력은 1기압 정도이며 헬륨가스는 액체로 변한다. 본 연구의 목적은 Gifford-McMahon 냉동기와 Joule-Thomson 냉동기의 혼합형인 극저온 냉동기를 설계, 제작하여 죠셉슨(Josephson) 소자를 이용한 SQUID(초전도양자 간섭장치), 여러 종류의 탐지기, 컴퓨터 소자 개발 등을 위한 냉동기로 사용하는데 그 목적이 있다. 개발되는 법동기의 용량은 1 W이며, 최저온도는 4K 정도가 된다.

  • PDF

80K 200W급 단단 G-M 극저온 냉동기 개발에 따른 성능평가(2)

  • Lee, Dong-Ju;Han, Myeong-Hui;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.93.1-93.1
    • /
    • 2015
  • 근래 디스플레이 분야에서 OLED가 시장을 주도하면서 이 공정에 가장 적합한 진공펌프로 크라이오 펌프가 주목을 받고 있다. 화소 형성 공정에 사용되는 유기물이 수분에 취약하기 때문인데, 크라이오 펌프가운데서 특별히 수분만 집중적으로 배기할 수 있는 워터펌프(CWP or cold trap)가 각광받고 있다. 이에 HM GVT는 중소기업청 중소기업개발지원사업의 일환으로 진행된 2014년도 구매조건부 신제품 개발사업에 선정되어 '극저온 G-M냉동기를 이용한 대용량 Cold Trap개발' 과제를 수행하면서 32인치 급으로 수분에 대해서 30,000 [L/s] 이상의 배기속도를 가지는 대형 CWP를 개발하고 있다(수요처: (주)아바코). 통상적으로 흡기구가 30인치라면 수분 배기속도는 대략 65,000 L/s에 이르고 200 W 냉각능력이면 최대 수분 분압 0.008 mbar에서 작동시킬 수 있다. 따라서 1차년도의 목표는 큰 배기용량과 대형 사이즈의 CWP를 개발하기 위해 80 K에서 200 W 이상의 냉동능력을 보유한 단단 G-M 극저온냉동기를 선행 개발하는 것이다. 이에 현재 최대 냉동능력 80 K에 130 W의 냉동능력을 가지는 HPS055모델을 이용하여 다양한 예비시험들을 수행하여 최적의 설계인자들을 도출하였고 이를 근거로 80 K에서 200 W 이상의 냉동능력을 가지는 HPS80200모델을 설계 및 제작, 성능시험을 수행하였다. 이에 국내 최초로 80 K에서 200 W의 냉동능력을 가지는 단단 G-M냉동기를 개발하였고 설계 및 제작에 대한 원천기술을 확보할 수 있었다.

  • PDF

Analysis of In-situ Temperature Measurement at Gonjiam Cold Storage Cavern (곤지암 지하암반 저장고 온도계측 결과 분석)

  • Lee Gyu-Sang;Lee Chung-In
    • Tunnel and Underground Space
    • /
    • v.15 no.3 s.56
    • /
    • pp.169-176
    • /
    • 2005
  • The decreasing pattern of underground temperature measured at 'Gonjiam cold storage cavern' during 7 years which was the first commercial scale underground food storage cavern in Korea was analyzed. The variation of energy consumption was discussed by comparing the consumed energy at the initial operation stage with that at later stage, when the temperature distribution reached a stabilized condition. The point to be considered at the design stage was also discussed by comparing the required refrigerator capacity at the initial operation stage with that at later stage. The extra energy to freeze the groundwater contained in pore space was discussed by analyzing the changing pattern of the rock temperature. The variation of measured rock temperature was compared with the estimated temperature using a numerical code, FLAC. The accuracy of the numerical estimation was discussed by comparing the heat flux measured by the operation time of the refrigerator with that estimated numerically.

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF