• Title/Summary/Keyword: 냉동성능

Search Result 382, Processing Time 0.032 seconds

A Study on the Dehumidification effect of Adsorbent at low Temperature (저온에서 흡착제의 제습효과에 대한 연구)

  • Lee, Min-Seok;Jeong, Yun-Ho;Lim, So-Min;Heo, Jae-Woo;Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.177-182
    • /
    • 2020
  • Interest in heat pumps is increasing as an eco-friendly and energy-saving heating method. In particular, in order to develop a heat pump capable of heating in a low-temperature area, research to prevent frost on the surface of the outdoor unit is increasing. In other words, when heating through a heat pump in a low-temperature area, a frost layer is formed on the surface of the outdoor unit, which lowers the heat transfer performance, thereby reducing the heating capacity. Therefore, in this study, an adsorption-type dehumidification system is attached to remove the moisture vapor of the air into the outdoor unit of the heat pump. It is believed that this study can suggest the most effective dehumidification method in low temperature regions. In addition, it is expected that a heat pump with high energy efficiency can be developed by attaching an adsorption dehumidifying system to the front of the outdoor unit of the heat pump.

A Performance Characteristics of a Solid Adsoption Heat Pump (흡착식 히트 펌프의 성능 특성)

  • 오후규;윤정인
    • Journal of the KSME
    • /
    • v.34 no.11
    • /
    • pp.877-886
    • /
    • 1994
  • 흡착계의 선택은 냉동기의 본질적인 성능을 결정하기 때문에 사용하는 열교환기의 전열특성, 시스템의 구성 등과 함께 중요한 위치를 차지하고 있다. 따라서 사용목적에 맞는 흡착계의 선 택이 중요하다. 여기서는 흡착식 히트펌프의 성능특성과 실용화를 위한 연구 개발 요점 등을 정리하였다.

  • PDF

Neuro-Fuzzy Diagnostic Technique for Performance Evaluation of a Chiller (뉴로 퍼지를 이용한 냉동기 성능 진단 기법)

  • Shin, Young-Gy;Chang, Young-Soo;Kim, Young-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.553-560
    • /
    • 2003
  • On-site diagnosis of chiller performance is an essential step fur energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for this purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

Steady-state Modelling of Centrigugal Chiller through On-Site Test (현장성능시험에 의한 터보냉동기의 정상상태모델 개발)

  • Chang, Young-Soo;Shin, Young-Gy;Baik, Young-Jin;Kim, Young-Il
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy (태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구)

  • Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.324-331
    • /
    • 2013
  • All evacuated tube collector is being constantly studied since it can reduce the conductive heat loss in absorber by using vacuum technology and has advantage of heat transport capacity and quick thermal response in comparatively small temperature difference. This study investigated the dynamic thermal performance of the solar collector with the control condition of solar irradiance and fluid temperature by using performance experimental apparatus which is combined with solar collector and refrigerator, examined the thermal characteristics in definite temperature range of fluid in constant temperature tank by simultaneously measuring refrigerating performance. As a result of it, I deducted the related equation of collector efficiency and found that mean collector efficiency has increased through quick heat transfer characteristics according to increase of outdoor temperature and irradiance in case of outlet temperature of constant temperature tank $22^{\circ}C$ when set outlet temperature of solar collector $25^{\circ}C$ with outlet temperature of constant temperature tank $18^{\circ}C$ & $22^{\circ}C$. Also COP of refrigerator was acquired value of 6.2~7.1 at outlet temperature of constant temperature tank $18^{\circ}C$.