• Title/Summary/Keyword: 냉동냉장창고

Search Result 31, Processing Time 0.022 seconds

A Study on the Analysis of Success Factors about Frozen and Refrigerated Warehouses using Fuzzy-AHP (Fuzzy-AHP를 활용한 냉동·냉장창고의 운영 성공요인 분석에 대한 연구)

  • Gu, Tae-Jun;Cha, Young-Doo;Nam, Tae-Hyun;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.121-131
    • /
    • 2017
  • The Fuzzy-analytic hierarchy process (AHP) was adopted as the methodology for this study because it allows for the use qualitative judgments by experts. Based on results of the analysis of the success factors for frozen storage/cold storage warehouses, the facility factor was identified as the most important to consider. This factor had a weight of 0.307, followed by systems and operations, accessibility, and standardization/automation with weights of 0.263, 0.255, and 0.175, respectively. The conclusions and implications of the study are as follows. First, the efficiency of constant temperature and humidity systems and the heat insulation property of buildings need to be enhanced. Second, the efficiency of the operations should be enhanced through the standardization of equipment rather than by standardizing product loading. Finally, since logistics and transportation costs are higher for frozen storage/cold storage warehouses than for general distribution, accessibility needs to be considered as the first priority.

A Study on the Applicable Fire Response Facilities in Cold Storage (냉장·냉동 창고 내 적용 가능한 화재대응시설에 관한 연구)

  • Lee, Jong-Gyu;Ju, Min-Eon;Min, Se-Hong
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.345-346
    • /
    • 2023
  • 본 연구에서는 냉장·냉동 창고의 화재 위험성을 최소화시키기 위해 적용 가능한 화재대응시설을 조사하고, 설치 시 발생할 수 있는 문제점을 파악하였다. 문제점을 해결하기 위해 국외에서 사용 중인 건식 스프링클러설비와 준비작동식 스프링클러설비의 작동 원리 및 특징을 분석하였다. 또한, 냉장·냉동 창고에서의 감지기 및 헤드의 오작동으로 인한 수손피해를 최소화할 수 있는 더블 인터록 시스템을 적용한 준비작동식 스프링클러설비의 적합성을 확인하였고, 이를 국내 냉장·냉동 창고에 적용하고자 한다.

  • PDF

A Study on the Adaptability of Oxygen Reduction System to Fire in Cold Storage through Fire Simulation Analysis (화재시뮬레이션 분석을 통한 냉장·냉동 창고 화재의 저산소 시스템 적응성에 관한 연구)

  • Min-Seok Kim;Sang-Bum Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.117-127
    • /
    • 2023
  • Purpose: The number of Cold Storages at home and abroad is on the rise, fires in large Cold Storages have recently occurred. As fires continue to occur and property damage is on the rise every year, the importance of preventing fires in large Cold Storage is growing. Method: Real Cold Storages were investigated on-site and fire cases were analyzed to derive and analyze fire risk, and the ORS, which is emerging as an adaptive fire prevention technology of Cold Storage, was investigated through FDS. Result: oxygen concentration 21, 15.7% and 17.7, 16.7% were analyzed through FDS, and flashover was reached within 3~4 minutes from 21, 17.7, 16.7%, but if oxygen concentration was lowered to 15.7%, it didn't ignite for 13 minutes. Conclusion: This study understood the concept and general part of the ORS, modeled the freezer through FDS, and analyzed the oxygen concentration to analyze the fire protection adaptability of the ORS. In the future, it is expected that large-scale empirical experiments and related regulations will be prepared to provide solutions for fire prevention in Cold Storages in blind spots of fire.

Investigation of Domestic Refrigeration and Freezing Warehouses (국내 냉장냉동 창고 현황 조사)

  • Sun, Il-suck
    • Journal of Distribution Science
    • /
    • v.6 no.2
    • /
    • pp.5-19
    • /
    • 2008
  • This study aims to provide the present general state of basic data about refrigeration and freezing warehouses scold storages because basic data about refrigeration and freezing warehouses are insufficient and imperfect at the moment. Research contents include the present general state of cold storages such as sales amount, capital(money invested), storage possession state by type, keeping area, cold storage facility capacity, and facility state such as existence of rack, building structure and floor height, and possessed facility state. According to research results, it was found that 86.7% of refrigeration and freezing warehouses are located in the capital region and Busan region in terms of regional distribution, and the average keeping area was found to be bigger in these two regions than that of other regions. In addition, the research shows that more than 80% of companies possess bonded warehouses and there was no big difference in the size and capacity of refrigeration and freezing warehouses. Regarding building structure, most of them were found to be reinforced concrete. However, only 25% of companies installed racks, but there was no statistical significance between existence of rack and the amount of capital and sales. Possessed facilities were found in the order of freight elevator, information system and dock. When it comes to cargo gear, companies were found to possess 9.1 units of forklift and 2.2 units of reach stacker in average. This research is expected to lay a basis for investigating, predicting and developing the local cold storage industry, and more detailed studies will be needed in the future.

  • PDF

Economical Efficiency Evaluation of the Cold Storage Warehouse with Various Envelope Structures (냉동냉장창고 외피구조 유형별 경제성 평가)

  • 송승영;석호태;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1156-1164
    • /
    • 2001
  • This study aims to suggest envelope structure which can improve the insulation performance of cold storage warehouse with cost effectiveness. Envelope structures are classified and economical efficiency of each type is evaluated to the model warehouse. As results, type 3 (PC wall) and 4(sandwich panel wall) have benefits to the middle/large (lifetime of 25 years) and small (lifetime of 12∼13 years) warehouse, respectively.

  • PDF

An analysis of the Factors of Moving in and Activation Strategies for Incheon Cold-Chain Cluster using LNG cold energy (LNG 냉열을 활용한 인천항 냉동·냉장 클러스터 입주요인 분석 및 활성화 방안 연구)

  • Ahn, kil-Seob;Oh, Jae-Gyun;Yang, Tae-Hyeon;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.17 no.2
    • /
    • pp.101-111
    • /
    • 2019
  • The construction of a "cold-chain cluster," which is a complex of cold-storage warehouses is emerging as an issue in the logistics industry. The Incheon Port Authority, in partnership with Korea Gas Corporation, is carrying out a project to build a cold-storage cluster using cold energy generated in the Songdo LNG receiving terminal. This study proposes a method of activating the cold-storage cluster using the CFPR methodology. An analysis of major factors showed that the most important factor was stability and profitability, which scored 0.281. For sub-factors, sustainable trade volume was the highest in importance, followed by rent level, the sustainability of LNG cold energy utilization technology, competition with general cold-storage warehouses, and exclusion of duplicate investments in facilities. For the future study, the evaluation of complex of cold-storage warehouses using major factors drawn out from this study is needed.

Sanitary Conditions for Cold and Frozen Food Storage Warehouses in Korea (국내 식품 냉장.냉동 창고 위생관리 수준 분석)

  • Choi, Eun-Ji;Kim, Mee-Hye;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.283-288
    • /
    • 2011
  • We surveyed the sanitary conditions for 17 cold and frozen food storage warehouses in Korea, using the following 5 inspections items: "putting into warehouse (A)", "prevention of cross-contamination (B)", "storage management (C)", "temperature control (D)", and "management of records and documents (E)", We included 20 detailed items. The results of distribution for frequency by five major inspection items showed that "(E)" was the highest, the next "(D)", "(C)"; and "(B)" was the lowest. In the correlation of inspection scores between total scores, "(B)" and "(C)" were highly related to the total score, therefore, the higher score of "(B)" or "(C)", the higher for the total score. In details of inspection items, "the management of cross-contamination upon taking product out of the warehouse" had the lowest score with a mean, of $2.67{\pm}1.80$, and also ranked as first of the 20 items.

Energy Saving Technique of Refrigeration Warehouse Cold Water Pump Using Photovoltaic Generation (태양광발전을 이용한 냉동.냉장창고용 냉수펌프의 에너지절감 기법)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Lee, Sang-Chip;Chung, Choon-Byeong;Lee, Hoon-Goo;Han, Kyung-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.92-99
    • /
    • 2005
  • We are interaction refrigeration warehouse cold water pump system and photovoltaic generation system. At this time, a target pressure is able to control in spite of change of the pressure according to pump head and rate of flow of pump. Also, we carry out the vector control of BLDC motor with the maximum torque operation and a high reliability from territory of each operation speed. Therefore, in this paper, we conclude energy saving technique of refrigeration warehouse cold water pump system.

Optimized Insulation Thickness of the Refrigerated Warehouse with Different Envelope Structures and Insulation Materials by L.C.C. Analysis (생애비용 분석을 통한 외벽 및 단열재료 종류별 냉동냉장창고 외피의 적정 단열두께 산정)

  • 강승희;구보경;황혜주;석호태;안홍섭;송승영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.372-381
    • /
    • 2003
  • This study aims to find out the optimized insulation thickness of refrigerated warehouse with different envelope structures (RC and PC wall) and insulation materials (urethane and icynene). Each of them is compared according to the thickness of insulation (100, 150, 200 mm/50 or 250 mm) and the temperature of cold storage room (0, -6, -15$^{\circ}C$). As results, it is proved to have the best economical efficiency in life cycle cost when PC wall with thickness of 100 mm (0 and -6$^{\circ}C$) and 150 m (-15$^{\circ}C$) urethane, respectively, are applied.

A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse (냉동냉장창고 침기방지장치의 성능평가에 관한 연구)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.