The Study on High Efficiency Cycle Characteristics of the Absorption Chiller (흡수식 냉동기 고효율화를 위한 사이클 설계)

  • Park, Chan-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.662-668
    • /
    • 2008
  • The objectives of the present work are to investigate the influence of the solution cooled absorber(SCA), refrigerant drain heat exchanger(RSX), exhaust gas/solution heat exchanger(ESX) and high efficiency solution heat exchanger on COP for a double-effect series-flow absorption chiller. A simulation program has been prepared for the cycle analysis of absorption chillers. As a result, solution heat exchangers(LSX, HSX) are the most effective element for the COP than the others. In spite of the poor contribution to COP, SCA plays an important role to reduce the crystallization phenomena of LiBr solution at solution heat exchanger. And the optimum solution split ratio varies with the relative size of RSX and LSX.

신경외과 수술에서의 인공 생체재료

  • Sim, Jae-Jun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.6.1-6.1
    • /
    • 2009
  • 신경외과는 뇌수술과 척추수술로 나눈다. 이중뇌수술 분야에서는 두개강내압 항진시 감압술이라고 '머리의 뚜껑을 연다'라는 표현과 마찬가지로 두개골의 일부분(손바닥크기)을 절제하는 수술이 있다. 이때 과거에는 떼어낸 뼈를 복부의 피하지방밑에 심어서 보관을 하다가 3-6개월 후 환자의 뇌상태가 안정이 되면 다시 꺼내어 제자리에 놓았는데, 골편이 피하지방에서 녹는 경우가 다소 있고, 복부에 이식한 장소가염증이 생기는 경우도 있어서 요즘은 냉동고에서 -70도를 유지하여 보관 후 나중이 복원 수술을 할 때녹여서 사용한다. 이를 '자가골 두개성형술' 이라 한다. 하지만골편의 오염이나 소실 혹은 1차 두개성형술 후 감염 등 어쩔 수 없이 자가골을 사용 못하는 경우에는인공으로 두개골편 모형을 제작하여 '뚜껑'으로 사용해야 한다. 현재PMMA를 이용하여 수술 시 모형을 제작하는 방법이 많이 사용되며 최근 단단한 스펀지 형태의 인공제품이 사용되고 있으나 가격이 매우비싸지만 스펀지 기공내로 자가골이 자란다는 장점이 있다. 척추수술 분야에서는 뼈 대치품을 비교적 많이필요로 한다. 즉 척추 후방고정을 하는 경우 원래 수술의 목적인 감압술이나 교정술 등을 한 후 척추분절간 쇠(티타늄사용)고정을 한 뒤에 뼈조직(자가골이나 동종이식골, DBM, HA stick) 등을 충분히 사용하여덮어줌으로써 분절간 골유합을 유도할 때 많은 양이 필요하며, 척추 전방으로 수술을 하는 경우에도 디스크공간이 빈 상태에서 Cage(추체와 추체를 지지하는 작은 상자모양) 내에뼈조직을 넣어서 척추분절간 골유합이 일어나도록 한다. 최근 HA를 cage 대용품으로 사용한 경우에서 HA가 부서지는 경우가 기사화된바 있다. 또한 경추의 추체 내에 작은 구멍만 뚫고 디스크 수술을 한 후에 그 구멍에 HA+B-TCP 소재를 넣어 천연뼈의 성장 유도를 위해 사용되는 등 신경외과의 다양한 분야에서 생체소재들이 사용되고 있다.

  • PDF

A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser (응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구)

  • Park, Chan-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.

Optimal Design of Blowing Plates to Minimize the Freezing Phenomena in the Freezer of a Side-by-side Refrigerator (양문 여닫이형 냉장고 냉동실 결빙 최소화를 위한 토출구형상 최적설계)

  • Kwak, S.M.;Lee, Y.H.;Kum, J.S.;Kim, N.S.;Kim, S.B.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.17-22
    • /
    • 2003
  • As side-by-side refrigerators came into existence, there has been a growing concern about the free%ins-up of the vital equipment in a walk-in freezer. Due to a bad performance, customers are experiencing too much frustration. In order to minimize the freezing phenomena, the numerical simulation has been performed on the characteristics of cold air flow in a side-by-side refrigerator. The flow field has been simulated with a standard $k-\varepsilon$ turbulent model and a SIMPLE algorithm based on the finite volume method. Through the results of the analysis of the pattern of cold air flow, finally the shape of outlet for cold air flow was modified. The present model was compared with the modified model. The latter was better than the former in minimizing the freezing phenomena.

  • PDF

An Analysis of the Patent for Highly Efficient Absorption Refrigeration System (고효율 흡수식 냉동기의 특허기술 분석연구)

  • 심윤희;박윤철;배영문
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.332-339
    • /
    • 2004
  • A technical analysis was conducted to predict the development trend for the highly efficient absorption type refrigeration system. The study was based on a submitted patent during January 1981 and December 2000 in Korea, Japan and America. The total number of extruded patents from the registered database was 24,822 and the filtering process makes the reduction of the data number to 3,510. Technical development of Japan for the absorption type refrigeration system is prominent compared to the other country due to approximately 75% of the patents coming from Japan. When the patent is divided into two categories, the patent for component technology for the refrigeration system makes up 75% and the refrigerating type technology 25% of the patents. This shows technical development for the system component is advanced compared to the technology development for the system type. When the patents are classified by nationality of patent applicants, foreigners contribute up to 33% of the patents in Korea. However, Japan's case shows the 99% of the patents are invented by the Japanese. If the patents are classified to the International Patent Classification, most of the data for the absorption type refrigeration system belongs to IPC F25B.

Operating Number Control of Compressors Based on Cooperative Logic for a High Efficiency Centrifugal Water Chiller (터보냉동기의 고효율 운전을 위한 협조 방식 기반의 압축기 대수제어)

  • Jeong, Seok-Kwon;Lim, Seung-Kwan;Ryu, Keon-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.233-240
    • /
    • 2015
  • This paper discusses compressors operating number control strategy using cooperative logic to cope with variable partial load for high efficiency of a centrifugal water chiller. The cooperative logic is composed of a speed-up and speed-down controller, enabling smooth operation of compressors and equivalent distribution of thermal load in each compressor. This centrifugal water chiller design can be operated with high efficiency without incurring excessive energy waste and large transient phenomena at partial load states. Simulations in MATLAB and experiments in a real chiller system were conducted and verified the high efficiency control of a centrifugal water chiller achieved by the suggested strategy.

크라이오펌프 국산 개발품 공정 신뢰성 및 내구성 시험

  • In, Sang-Ryeol;Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.119-119
    • /
    • 2013
  • 5년 동안 진행된 고진공 펌프 개발 사업의 일환으로 맥동관형 냉동기에 활성탄 어레이를 장착한 흡기구 직경 14인치 국산 크라이오펌프 완제품이 만들어졌다. 이미 지난해에 완성한 시제품을 가지고 모든 배기성능시험을 완료하고 목표를 뛰어 넘는 성능을 가지고 있음을 입증하였지만 완제품의 경우는 현장에서 스퍼터링 공정에 대한 신뢰성과 열적 내구성 시험이 중요한 항목으로 대두되었다. 개발된 펌프를 생산 공정에 직접 투입하는 모험을 하지 않으면서도 신뢰성을 확보하는 방편으로 카이스트 나노종합팹 센터에서 가동중인 스퍼터링 장비에 완제품을 달고 기존 공정과 같은 방식으로 장치를 운영하면서 외제 상용품을 사용했을 때와 진공성능 및 공정수율을 비교하는 시험을 수행하였다. 또 내구성 시험 항목으로 열부하 시험과 열 사이클 시험을 수행하였다. 열부하 시험은 300도까지 온도를 올릴 수 있는 열판을 펌프 흡기구 배플 앞에 설치하여, 냉동기 2차 냉각단 온도가 20 K 이하로 유지될 수 있는 최대 허용 복사열을 측정하는 방식으로 진행되었으며 열 사이클 시험은 크라이오 펌프의 활성화 기능을 활용하여 완전 활성화(full regen., 10K-300K-10K) 과정을 10회 연속 시행하여 펌프의 배기성능과 기계적 이상 유무를 관찰하였다.

  • PDF

A Study on the Heat Loss Effect of Steel Structure in a Refrigerator Mullion (냉장고 멀리언부 구조보강용 철구조물의 열손실 영향 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • The present study has been carried out to reduce the heat loss from a refrigerator by numerical heat transfer analysis and temperature measurement experiment for the verification of heat transfer analysis result. To perform this purpose, two dimensional heat transfer analysis and measurement of temperature on the surface of freezer for the horizontal cross sectional plane of a refrigerator has been accomplished. From the present study, it could be seen that the steel support in the mullion near gasket region has a heat transfer characteristics which transfer outside heat well from the high temperature hotline and outside air to the inner refrigerator. The effect of removing steel support on the reducing heat loss of a refrigerator was 24.8% and removing steel support might introduce significant improvement of refrigerator heat loss.

EFFECTS OF CONDENSED PHOSPHATES ON THE DENATURATION OF ALASKA POLLACK MUSCLE DURING REFREEZING AN COLE STORAGE (재동결 명태육의 냉동변성에 미치는 축합인산염처리의 효과에 대하여)

  • KANG Yeung-Joo;PARK Yeung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1975
  • The present study was ,conducted to evaluate the effects of condensed phosphates on the refeezing damage of Alaska pollack muscle. The fillets were dipped in such solution as 5 and $10\%$ sodium polyphosphate, 1 and $5\%$ mixture of sodium polyphosphate and sodium pyrophosphate (1:1, w/w) for 1 and 5 minutes, respectively, before refreezing. And fillets were frozen at $27^{\circ}C\~28^{\circ}C$ and stored for 15 days at $-18^{\circ}\~-20^{\circ}$. The degree of denaturation was estimated by determining amounts of drip relased, content of total solids, nitrogen, and DNA in the drip an cooking-weight-loss. Phosphorus absorbed in the muscle was also determined. Phosphorus absorbed in the fillets treated with loft solution of sodium polyphosphate for 5 minutes amounted to 101 mg/100g muscle as $P_2O_5$. The absorption was dependent on tile concentration of treating solution rather than on the dipping time. The increase of phosphorus absorption seemed to affect to reduction of drip. Among the treating conditions, $10\%$, 5 minutes and $10\%$ 1 minute with sodium polyphosphate appeared most effective ones on drip reduction. The effect of $5\%$, minutes with the mixture of sodium polyphosphate and sodium pyrophosphate did not show so benefitable effect in refrozen fillets. As a tendency total solids, nitrogen, and DNA in tile drip varied proportionally to the amount of drip released. And the content of DNA was lower than the amount. Treatment, at higher the concentration and longer the dipping time, resulted in the lower cooking-weight-loss and the better quality on organoleptic test of thawed fillets.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF