• Title/Summary/Keyword: 냉각 팬

Search Result 175, Processing Time 0.03 seconds

Fan Noise Prediction Method of Air Conditioning and Cooling System (공기조화 및 냉각시스템의 팬 소음예측 기법)

  • Lee, Jin-Young;Lee, Chan;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1318-1320
    • /
    • 2007
  • Fan noise prediction method is presented for air conditioning and/or cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(Flow Network Modeling) with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual noise test results.

  • PDF

Automatic 3-D Modeling System for Cooling Fans Based on a Solid Modeler (솔리드 모델러 기반의 냉각탑용 축류팬 자동 설계시스템)

  • 이광일;강재관;김원일;이윤경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.141-144
    • /
    • 1997
  • This paper presents design automation system using API and parametric modeling of solid modeler, which is applied on axial fans for cooling towers. The design data including chord length and twist angle according to the fan length are given by design program, and API functions are applied to automate the modeling and assembly process of fan blade. The boss to connect fan and motor is designed with parametric design function provided by UG so as to be flexibly changed by the value of design parameters. The process of generating 2-D drafting for parts and an assembly is also automated. With developed system, the modeling time is reduced to 5 minutes even with unskilled operators.

  • PDF

Flows through Evaporator for Cooling (증발기 냉각 팬에 의한 유동)

  • Kim Jae Won;Kim Nam Wook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.499-502
    • /
    • 2002
  • The present study has been carried out for understanding of flows over an evaporator in cooling system of water. Main emphasis is to decide the flow patterns in order to enhance the flow rate with low noise level. Two cases aye examined for comparison of flows; one is blowing system and the other is suction style with respect to Inn system. Present methodology for this work is PIV (Particle Image Velocimetry) techniques and Rot-wire anemometer for velocity measurements and wind tunnel for performance of the present fan. Consequently, it is found that flows passing evaporator and other components for cooling are more effective than the suction flows. Flow details with performance of fan system are also presented for proper explanation of the conclusion.

  • PDF

Noise Control for Diesel Engine Generator Sets (디젤 엔진 발전기 세트의 소음제어)

  • 남경훈;주현돈;최부군;박실룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.165-170
    • /
    • 1995
  • 소음저감 설계기술은 제품의 경쟁력 향상을 위해 일반인이 쉽게 접근할 수 잇는 가전제품, 자동차, 항공기 분야 등에서 많은 연구가 수행되어 왔으며, 최근 소음환경 규제가 강화되고 대형기계의 설치 위치가 주거지역과 가까워지므로 산업용 기계설비의 소음제어에 대한 관심이 점차 증대되고 있다. 특히 디젤 엔진 발전기 세트를 이용해서 전원을 공급하는 산업용 기계에 있어서는 디젤 엔진과 발전기가 주소음원이며, 크게 기계적 소음, 공기 역학적 소음, 그리고 전자기 소음 등으로 분류된다. 본 연구는 이러한 소음을 발생시키는 엔진(Engine), 발전기(Generator), 방열팬(Radiator Fan) 등의 성능을 개선시켜 소음을 감소시키는 것이 아니라, 외부 덮개(Canopy)에 흡음재를 부착하여 소음저감 방법을 채택했다. 연구대상으로서는 항만에서 컨테이너(Container)를 운송하는 이동용 크레인(Transfer Crane)의 엔진 발전기 세트(set)로서, 각 구성품(엔진, 발전기, 방열 팬)의 음향 덮개의 내부구조를 설계하였다. 그리고 덮개 내부 온도를 일정하게 유지시키기 위하여 엔진에서 방사하는 방열공기와 내부로 흡입되는 냉각공기의 열유동장 해석도 병행하였다.

  • PDF

Design of an HTS Magnet for a 2.5 MJ SMES (2.5 MJ SMES용 고온초전도 마그넷 설계)

  • Lee, Se-Yeon;Kwak, Sang-Yeop;Kim, Young-Il;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Chan;Choi, Kyeong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.631-632
    • /
    • 2008
  • 본 논문은 2.5MJ의 저장용량을 가지는 SMES 용 고온초전도 마그넷의 설계에 관한 연구 결과이다. 선재는 2세대 고온초전도 선재인 YBCO CC를 2단으로 적층하여 사용하였다. 운전전류는 전도냉각 방식을 사용하는 것을 가정해 22K의 운전온도에서 선재의 임계전류를 고려하여 600A 이상으로 결정하였다. 마그넷의 형상은 싱글 솔레노이드와 토로이드 형태로 각각 설계하였고 싱글 솔레노이드는 더블 팬케이크 모듈코일을 적층하여 구성 토로이드는 싱글팬케이크 모듈코일을 배열하여 모듈러 토로이드로 구성하였다. 각 형상별 설계결과를 통해 저장에너지와 선재사용량 그리고 누설자장의 크기를 각각 비교하였다.

  • PDF

Fluid Flow and Heat Transfer Characteristics around a Surface-Mounted Module Cooled by Forced Air Flow by Piezoelectric Cooling Fan (압전세라믹 냉각팬에 의한 강제 공랭 모듈 주위의 유체유동과 열전달 특성)

  • Park, G.J.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.272-277
    • /
    • 2003
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. A flexible PZT fan with distortion in a fluid transport system of comparatively simple structure which was mounted on a PCB in a parallel-plate channel($450{\times}80{\times}700mm^3$) accelerates surrounding fluid locally. Input voltages of 20-100V and a resonance frequency of 23Hz were used to vibrate the cooling fan. Input power to the module was 4W. The cooling effect using a PZT fan was larger than that of free convection. Fluid flow around the module were visualized by using PIV system. The temperature distribution around heated module were visualized by using liquid crystal film(LCF). We found that the flow type was y-shaped and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

  • PDF

Flow Analysis for Design Modification of Marine Generator Fan (박용 발전기 냉각 팬 설계변경에 따른 유동해석)

  • Kim, Hong-Won;Seol, Sin-Su;Ha, Ji-Soo;Kim, Jin-O
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.840-844
    • /
    • 2003
  • A study for increase of fan flow rate by geometric modification has been conducted to decrease temperature rise of marine generator inner part. Through experiment of a real product, a performance curve for various flow resistances was obtained. Flow analyses for each cases were done by using commercial code-FLUENT and the results were very similar to experimental data (0.7% deviation at normal operating condition). Through flow analysis results for various design geometric modification, a scroll type fan was adopted as a best design geometry with 100Pa more pressure and 22% more flow rate than original fan.

  • PDF

Design of automotive engine cooling fan and study on noise reduction through modification of system (자동차용 냉각팬의 설계와 시스템 개선을 통한 저소음화 연구)

  • 김병주;강상규;김규영;이덕주;이재영;이덕호;신동수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.196-201
    • /
    • 2003
  • Axial fans are widely used for automotive engine cooling device due to their ability to produce high flow rate to keep engine cool. At the same time, the noise generated by these fans causes one of the most serious problems. Especially, engine cooling fan noise in idle condition of a car is noticeable. Therefore, the high efficient and low-noise fan is seriously needed. When a new fan system is designed, system resistance and non-uniform inflow are the key factors to get the high performance and low noise fan system. In this study, experimental study on the fan and system was carried out and brought a successful result of performance and noise from a designed fan. And through the modification of the fan system, the fan produced more flow rate and became less noisy.

  • PDF

Evaluation of idle vibration beated by cooling fan imbalance (팬 작동에 따른 비팅성 아이들 진동 평가)

  • Park, Jinhan;Ahn, Sejin;Jeong, Weuibong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.247-249
    • /
    • 2014
  • The beating phenomenon occurs because of various causes, when idle vibration was happened. In this study, the beating phenomenon was divided into several parameters and controlled by the parameter. It was hypothesized that the beating parameter is related to discomfort of idle vibration. The three-down one-up method was performed for evaluating discomfort of controlled vibrations, which is widely used in the field of psychophysics. As a result in pilot test, a subject responds beating vibration more discomfort than normal idle vibration. In the future, the study will be implemented to know how much the parameters of beating signal affect to the discomfort at idle vibration in passenger vehicle.

  • PDF

Study on Flow Resistance by the Design of Cooling Fan (냉각 팬의 설계에 의한 유동저항에 관한 연구)

  • Cho, Jae-Ung
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • In this study, the structural analysis of cooling fan is combined with 3-D flow analysis by using CFD on fluid domain. The smoothly cooling flow with optimum design of cooling parts is essential at automotive combustion engine. The fan shape is modeled with three kinds of shape by varying the radius of the fan blade. By the results of analysis, the flow at Model I is more uniform than Model II or III. And the displacement at Model I is less than Model II or III. As the flow resistance of cooling fan at Model I decreases more than Model II or III, the efficiency becomes better.