• Title/Summary/Keyword: 냉각효율

Search Result 584, Processing Time 0.03 seconds

Performance Analysis of Hybrid SOFC/Uncooled GT System for Marine Power Applications (선박동력용 SOFC/GT(무냉각) 하이브리드시스템의 성능 평가)

  • Kim, Myoung-Hwan;Kil, Byung-Lea
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1050-1060
    • /
    • 2012
  • As an approach to high-efficiency of SOFC system, SOFC/GT Hybrid system is effective. However, if the output size of the system belongs to the marine class of dozens MWs, the introduction of the cooling system of GT system, which is used as sub-system, makes its related devices complicated and also makes its control difficult. Accordingly, for the marine use, SOFC/GT (non-cooling)Hybrid system looks more suitable than SOFC/GT(cooling)Hybrid system. This study established the SOFC/GT (non-cooling)Hybrid system, and examined the operating temperature & current density of the stack for the system, pressure ratio of the gas turbine, the influence of TIT(Turbine Inlet Temperature) on system performance, etc. through the simulation process. Through this research process, this study was able to confirm that electrical efficiency rises in spite of the increase in the required power for the air compressor, and there exists a limited range of temperatures for operation in TIT.

소형(600l/min 급) 공랭식 건식진공펌프 기술 개발 연구

  • Yu, Jae-Gyeong;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.221-221
    • /
    • 2012
  • 최근 진공 산업은 반도체 산업의 급속한 발전과 더불어 진공 산업이 핵심기술로 부각되고 있으며, 진공 산업의 발전이 고부가가치를 창출하는 산업으로 발전하고 있는 추세이다. 이에 (유)우성진공 기술연구소에서는 국내에서 개발이 전무한 소형급 600l/min. 급의 배기속도를 가지는 공랭식 건식진공펌프 개발과 더불어 중소기업 혁신기술 개발사업의 성공적인 수행으로 인해 상용화 단계에 있다. 본 연구에서는 소형(600l/min. 급) 공랭식 건식진공펌프에 개발 과정 및 성능에 대해 소개하고자 한다. 우선, 여타 건식진공펌프와는 달리 냉각방식이 수냉식이 아니라 공랭식 이라는 점에서 에너지 절감 및 설치 공간 제약이 없으며, 유지 비용을 절감할 수 있는 장점을 가지며, 국내에서는 소형급의 건식진공펌프가 없는 관계로 시장성을 높게 평가하고 있다. 소형급 공랭식 건신진공펌프의 냉각효율을 고려하여 하우징을 알루미늄 합금으로 제작을 하였으며, 냉각핀을 적절하게 배치하여 압축열을 효과적으로 방출하기 위한 구조가 될 수 있도록 설계하였고, 냉각팬에 의한 공랭효과를 극대화하기 위해 펌프 스킨을 사용하여 공기 유로를 형성토록 하였다. 또한, 루츠의 형상 및 각 단의 압축효율을 고려한 최적의 로터를 설계하기 위해 Involute Curve를 이용한 3-Lobe형 로터를 설계하였으며, 로터와 로터간의 Clearance를 유지 할 수 있도록 설계하였다. 향후 최적화된 로터 설계기술과 이형재질(알루미늄과 주철)간 열팽창이 고려된 적절한 clearance 유지기술을 적용하여 안정적인 배기속도 600l/min.와 도달진공도 0.005 torr를 가지는 소형 공랭식 건식드라이펌프를 상용화 하고자 한다. 또한 성공적인 과제 종료 및 기술 개발에 따라 건식진공펌프 시장에 신기술 개발 확산에 따른 기업들 간의 기술 경쟁력 촉진을 통한 국가 기술력 향상을 기대해 볼 수 있다.

  • PDF

Study of On-chip Liquid Cooling in Relation to Micro-channel Design (마이크로 채널 디자인에 따른 온 칩 액체 냉각 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.31-36
    • /
    • 2015
  • The demand for multi-functionality, high density, high performance, and miniaturization of IC devices has caused the technology paradigm shift for electronic packaging. So, thermal management of new packaged chips becomes a bottleneck for the performance of next generation devices. Among various thermal solutions such as heat sink, heat spreader, TIM, thermoelectric cooler, etc. on-chip liquid cooling module was investigated in this study. Micro-channel was fabricated on Si wafer using a deep reactive ion etching, and 3 different micro-channel designs (straight MC, serpentine MC, zigzag MC) were formed to evalute the effectiveness of liquid cooling. At the heating temperature of $200^{\circ}C$ and coolant flow rate of 150ml/min, straight MC showed the high temperature differential of ${\sim}44^{\circ}C$ after liquid cooling. The shape of liquid flowing through micro-channel was observed by fluorescence microscope, and the temperarue differential of liquid cooling module was measuremd by IR microscope.

Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet (단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측)

  • Kim, Myung-Ho;Kim, Byoung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.892-897
    • /
    • 2020
  • Previous plastic heat exchangers are expensive because the mold must be newly manufactured depending on the air conditioning space. On the other hand, danpla is so thin that the heat exchange performance is excellent. Moreover, danpla can be used easily in ventilation systems in view of fabrication. This study proposes correlations for the cooling performance of an indirect evaporative cooling system. The experimental apparatus consisted of a heat exchanger, spray nozzle, fan, thermostat, pump, and measuring sensors for temperature, humidity, and airflow rate. The results showed that the effectiveness decreased gradually as the airflow rate increased. In addition, there was an optimal condition in terms of effectiveness. The performance prediction correlations were determined using the experimental data from various conditions. The proposed correlations showed performance accuracies within 4 % error.

CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency (과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구)

  • Koo, Seongmo;Chang, Hyuksang
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2017
  • Numerical analysis was done to evaluate the fluid distribution inside of the mixing quencher to increase the reaction efficiency of the aqueous hydrogen peroxide solution in the scrubbing column which is used for simultaneous desulfurization and denitrification. Effective injection of the aqueous hydrogen peroxide ($H_2O_2$) solution in the mixing quencher has major effects for improving the reaction efficiency in the scrubbing column by enhancing the mixing of the aqueous $H_2O_2$ solution with the exhaust gas. The current study is to optimize the array of nozzles and the spray angles of the aqueous $H_2O_2$ solution in the mixing quencher by using the computational method. Main concerns of the analysis are how to enhance the uniformity of the $H_2O_2$ concentration distribution in the internal flow. Numerical analysis was done to check the distribution of the internal flow in the mixing quencher in terms of RMS values of the $H_2O_2$ concentration at the end of quencher. The concentration distribution of $H_2O_2$ at the end of is evaluated with respect to the different array of the nozzle pipes and the nozzle tip angles, and we also analyzed the turbulence formation and fluid mixing in the zone. The effect of the spray angle was evaluated with respect to the mixing efficiency in different flow directions. The optimized mixing quencher had the nozzle array at location of 0.3 m from the inlet duct surface and the spray angle is $15^{\circ}$ with the co-current flow. The RMS value of the $H_2O_2$ concentration at the end of the mixing quencher was 12.4%.

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

A Flow Analysis on Wing Shape of Cooling Fan at Automobile (자동차에서의 냉각팬의 날개 형상에 대한 유동해석)

  • Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.4
    • /
    • pp.75-79
    • /
    • 2014
  • In this study, a flow analysis is carried out on the wing shape of cooling fan at automobile. By designing three kinds of Canival, Teracan and basic models with CATIA program, this analysis is done on the configuration of cooling fan with the same flow condition. It can be seen that the contour of flow velocity is changed due to the model of wing and the pressure distribution of fluid is changed due to the configuration or the area of wing. In case of cooling model of Teracan among three models, there is the most air flow and it can be thought to be most effective to cool the radiator. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.