• Title/Summary/Keyword: 냉각코일

Search Result 59, Processing Time 0.027 seconds

A Study on Performance Enhancement of AHU with a Pressure Type Fan (압입식 송풍방식을 적용한 AHU의 성능 향상을 위한 연구)

  • Jang, H.S.;Kim, E.P.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1164-1169
    • /
    • 2008
  • The miniaturization of the Air Handling Unit (AHU) has become an actual need because of the restriction of the using space on the vessel. In modern AHU’s construction, in which the fan section is at the end part of the ship, it’s very difficult to select a suitable capacity of evaporators, because the fan motor emits heat. Thus, the AHU structure has been changed as the fan section has been set before the cooling coil to get temperature values similar to the designed amount. Also, the air guider is installed in order to maintain equal air distribution after it passed the fan section. So, it is possible for air to equally pass the cooling coil. It is investigated three different geometries to find the best performance. Also, It is compared with the numerical and experimental results. The study found the case 3 gives the best results. The results of this study show the possible application of the new design.

Effects of Continuous Annealing Conditions on the Properties of Extra Low Cabon Steel Sheets Containing B, Nb and Ti (B, Nb 및 Ti를 함유한 극저탄소강판에서 연속열처리조건이 재질에 미치는 영향)

  • Lee, Jong-Mu;Yun, Guk-Han;Lee, Do-Hyeong
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.44-54
    • /
    • 1994
  • Effects of cooling rate, cold reduction %, continuous annealing treatments on the recrystallization texture structure of the A1 killed extra low carbon steel sheet contaning Ti, Nb, and B were investigated. The texture coefficient ratio TC (222)/TC (200) tends to increase with decreasing the cooling rate of the coling process and increasing cold reduction %. However, the texture coefficient ratio tends to decrease as the cold reduction % increases from 80% to 90%, which may be due to the change of the primary texture structure from {554} (225) to {ill] (1 1%). The optimum fabrication procedures for the steel sheet with a maximum texture coefficient ratio may be : furnance cooling after the coiling treatment, 80% cold reduction and the continuous annealing treatment of holding at 80O0C for 1 min., water quenching and then holding at $450^{\circ}C$ for 5min.

  • PDF

Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers (경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Heat Transfer and Pressure Drop of $CO_2$ Gas Cooler in a Helically Coiled Tube (헬리컬코일형 $CO_2$ 가스쿨러의 열전달과 압력강하)

  • Kyoung, Nam-Soo;Yu, Tae-Guen;Son, Chan-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.246-247
    • /
    • 2005
  • The paper presents the heat transfer characteristics during cooling process of carbon dioxide($CO_2$) in a helically coiled tube. The main components of the apparatus consist of a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section with the inner diameter 4.55 [mm] is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The main results were summarized as follows : The heat transfer coefficient increases with respect to the decrease of the gas cooler pressure in a supercritical region and the increase of the refrigerant mass flux. The pressure drop decreases in increases of the gas cooler pressure and increases with respect to increases the refrigerant mass flux.

  • PDF

Design of an HTS Magnet for a 2.5 MJ SMES (2.5 MJ SMES용 고온초전도 마그넷 설계)

  • Lee, Se-Yeon;Kwak, Sang-Yeop;Kim, Young-Il;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Chan;Choi, Kyeong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.631-632
    • /
    • 2008
  • 본 논문은 2.5MJ의 저장용량을 가지는 SMES 용 고온초전도 마그넷의 설계에 관한 연구 결과이다. 선재는 2세대 고온초전도 선재인 YBCO CC를 2단으로 적층하여 사용하였다. 운전전류는 전도냉각 방식을 사용하는 것을 가정해 22K의 운전온도에서 선재의 임계전류를 고려하여 600A 이상으로 결정하였다. 마그넷의 형상은 싱글 솔레노이드와 토로이드 형태로 각각 설계하였고 싱글 솔레노이드는 더블 팬케이크 모듈코일을 적층하여 구성 토로이드는 싱글팬케이크 모듈코일을 배열하여 모듈러 토로이드로 구성하였다. 각 형상별 설계결과를 통해 저장에너지와 선재사용량 그리고 누설자장의 크기를 각각 비교하였다.

  • PDF

$H_2$ sensor for detecting hydrogen in DI water using Pd membrane (발전기 스테이터의 냉각코일에 pinhole 발생을 검지 할 수 있는 수소센서 개발)

  • Choi, Sie-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.442-445
    • /
    • 1999
  • In this work, to detect of hydrogen in DI water in the generator area of nuclear power plants was fabricated Pd/Pt gate MISFET sensor using Pd membrane. $H_2$ permeation through Pd accounts for external mass transfer, surface adsorption and desorption, transitions to and from the bulk metal, and diffusion within the metal. The identification of pinholes in the generator area of plant is an important safety consideration, as hydrogen build-up gives rise to explosion. For this type of application the sensor needs to be isolated in DI water, accordingly, a Pd membrane was used to separate the DI water. The hydrogen in the DI water was then absorbed on the Pd thin film and diffused into the oil through the thin film. The Pd/Pt gate MISFET sensor, encapsulated by oil, will thereby detect permeated hydrogen.

  • PDF

Numerical Analysis on the Heat Transfer Characteristics of Syngas Cooling System of an IGCC Process (IGCC 합성가스 냉각 시스템의 열전달 특성 연구)

  • Oh, Junho;Ye, In-soo;Park, Sangbin;Ryu, Changkook;Park, Sungku
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.65-68
    • /
    • 2013
  • In a syngas cooling system of coal gasification process, fly slag carried by syngas deposit on the surface of heat exchanger. The deposited materials form a fouling layer with several millimeters thickness, disturbing heat transfer between steam and syngas. This study investigates flow and heat transfer characteristics of syngas in helical coil heat exchanger using computational fluid dynamics under clean and fouled surface condition. Process model were also designed and its results are in good agreement with CFD results.

  • PDF

A Study on the Flow Characteristics around Cooling Tubes of Fan Coil Unit for Ship (선박용 팬코일장치 냉각관 주위의 유동특성에 관한 연구)

  • Bae, Bong-Gap;Choi, Keom-Ran;Ro, Byeong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.151-156
    • /
    • 2009
  • This experimental study investigated in to the flow characteristics around staggered cooling tube arrays of fan coil unit for ship. A particle image velocimetry technique was employed to obtain detailed measurements at inlet-velocity-based Reynolds numbers of $Re=1.5{\times}10^3{\sim}Re=2.5{\times}10^3$. As for the results, the flow evolves rapidly and becomes spatially periodic in the streamwise direction after a relatively short distance. The flow exhibits strong Reynolds number dependence in developing region but no significant Reynolds number effects are observed in spatially periodic region.

  • PDF