• Title/Summary/Keyword: 냉각온도변화

Search Result 538, Processing Time 0.035 seconds

A Numerical Simulation of Regenerative Cooling Heat Transfer for the Rocket Engine (로켓엔진의 재생 냉각 열전달 해석)

  • 전종국;박승오
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.46-52
    • /
    • 2003
  • This paper presents the numerical thermal analysis for regeneratively cooled rocket thrust chambers. An integrated numerical model incorporates computational fluid dynamics for the hot-gas thermal environment, and thermal analysis for the liner and coolant channels. The flow and temperature fields in rocket thrust chambers is assumed to be axisymmetric steady state which is presumed to the combustion liner. The heat flux computed from nozzle flow is used to predict the temperature distribution of the combustion liner As a result, we present the wall temperature of combustion liner and the temperature change of coolant.

Cooling Performance of PC cooling Fan For Various Cooling Fan Blade numbers and Design Shapes (PC용 냉각팬의 형상 및 블레이드의 수 변화에 따른 냉각성능)

  • Park, Won-Keol;Lee, Dong-Ryul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.685-689
    • /
    • 2012
  • 본 연구는 PC용 냉각팬의 효율적인 설계를 위하여 냉각팬의 형상 변경 및 블레이드의 수 변화를 통해서 PC 부품 발열체의 온도변화를 수치해석적으로 수행하였다. 기존의 냉각팬 형상을 기준으로 블레이드의 수를 변화시키고 실제 형상을 변경한 냉각팬을 동일한 설계 입력조건를 적용하여 비교 분석하여 냉각성능을 파악하였다. 두 Case를 비교한 결과 기존 형상은 블레이드의 수가 증가 할수록 냉각효과가 커졌고, 형상을 변경한 냉각팬의 경우 Blade 6에서 가장 큰 냉각 효과를 보였다. 그리고 Blade 6과 8을 비교해 봤을 때 두 블레이드 사이에서 온도차이는 미소한차이로 냉각효과를 비교하기 어려웠다. 두 Case에서 제작과정과 비용을 비교해 보았을 때 Case 2의 Blade 6 경우가 더 우수한 것으로 보아 형상을 변경한 블레이드에서 최적설계를 얻을 수가 있었다.

  • PDF

A study on the characteristic of vegetables temperature in the pre-cooling vacuum unit (진공 예냉장치 내에서의 야채류의 온도 변화 특성에 관한 연구)

  • Won, Jong-Ho;Park, Sang-Gyun;Yoon, Seok-Hoon;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.879-884
    • /
    • 2007
  • This study is to observe the change of temperature and relative humidity for various vegetables in vacuum precooling system. The materials for experiments were the lettuce, chinese cabbage, pak choi and cabbage. The experimental apparatus was constructed of vacuum chamber, vapor/water separator, water tank, pumps ejecting and cooling water circulation, refrigerator unit, cooling coil for water cooling, Hygrometer and Data logger measuring of the temperature change. The experiments were operated in 20torr and recorded every 3 minutes. It was found that the cooling temperature and speed of vegetables are depending on the percentage of its water content. The more water contains, the faster cooling speed and the lower cooling temperature.

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

Effect of Thermal Barrier Coating and Film Cooling Condition on the Cooling Performance of Liquid-propellant Rocket Engine Combustor (액체로켓 엔진 연소기의 열차폐 코팅 및 막냉각 조건에 따른 냉각 성능 변화 해석)

  • Joh, Miok;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.2
    • /
    • pp.52-59
    • /
    • 2014
  • The effect of ceramic thermal barrier coating thickness on the cooling performance of a liquid-propellant rocket engine combustor has been investigated through combustion/cooling performance analysis whose results verified against measured data from hot-firing tests. Also have been confirmed the effects of film cooling amount near the face plate on the coolant temperature and on the thermal barrier coating surface temperature. Some important points to be considered for designing cooling schemes for regeneratively cooled rocket engine combustor have been drawn and reviewed from present study and further verification of the analysis tool should be performed in the future.

Transient Analysis on Heat Transfer of Rocket Engine Combustion Chamber Considering Film-cooling (막냉각을 고려한 로켓엔진 연소실 열전달 비정상 해석)

  • Ha, Seong-Up;Moon, Il-Yoon;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.867-868
    • /
    • 2011
  • Transient Analysis on heat transfer of rocket engine combustion chamber and wall temperature variation was carried out, especially, calculations of LOx/kerosene rocket engine with/without fuel film-cooling were conducted. Convective and radiative heat flux inside combustion chamber wall were calculated by the empirical equations for rocket engine combustion, and conduction of wall interior was calculated by numerical method with 2D axisymmetric grid. In this calculations the transient variations of wall temperature, the location changes of peak temperature and so on affected by film-cooling were analyzed.

  • PDF

Investigation of Cooling Performance of Injection Molds Using Pulsed Mold Temperature Control (가변 금형온도 제어기법을 적용한 사출금형의 냉각성능 고찰)

  • Sohn, Dong Hwi;Park, Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • In injection molding, the mold temperature is one of most important process parameters that affect the flow characteristics and part deformation. The mold temperature usually varies periodically owing to the effects of the hot polymer melt and the cold coolant as the molding cycle repeats. In this study, a pulsed mold temperature control was proposed to improve the part quality as well as the productivity by alternatively circulating hot water and cold water before and after the molding stage, respectively. Transient thermal-fluid coupled analyses were performed to investigate the heat transfer characteristics of the proposed pulsed mold heating and cooling system. The simulation results were then compared with those of the conventional mold cooling system in terms of the heating and cooling efficiencies of the proposed pulsed mold temperature control system.

Thermal Analysis of Exhaust Diffuser Cooling Channels for High Altitude Test of Rocket Engine (로켓엔진 고공환경 모사용 디퓨져의 냉각 채널 열 해석)

  • Cho, Kie-Joo;Kim, Yong-Wook;Kan, Sun-Il;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.193-197
    • /
    • 2010
  • Water cooling ducts are installed in the exhaust diffuser for high altitude tests of rocket engine to protect diffuser from high-temperature combustion gas. The mass flow rate and pressure of cooling water is designed to prevent boiling of cooling water in the ducts. Therefore, the estimation of maximum temperature of duct wall is important parameter in design of cooling system, especially pressure of cooling water. The method for predicting maximum temperatures of duct walls with variation of coolant flow rates was derived theoretically.

Cooling Performance Analysis of a Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution is verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature. Required coolant flow rate is determined for given chamber pressure. Cooling performance is also predicted for temperature dependant coolant properties.

Study on Regenerative Cooling Characteristics for Rocket Engine Using LNG as a propellant (액화천연가스 로켓엔진의 재생냉각 특성 연구)

  • 장행수;한풍규
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.16-17
    • /
    • 2002
  • 재생냉각은 엔진 경량화 및 높은 추력을 발생시킬 수 있으며 엔진이 장시간 작동할 경우에도 추력의 변화가 일어나지 않는 우수성으로 인해, 액체로켓엔진에서 보편적으로 사용되고 있는 냉각방식이며, 고성능 액체로켓엔진 개발에 있어서 핵심기술이다. 일반적으로 재생냉각 방식은 연소기 내벽에 형성된 냉각유로에 연료 또는 산화제를 흘려보내 고온고압의 연소실내에 온도 경계층을 생성시키면서 벽면온도를 적정온도 이내로 유지하는 것이 목적이며, 또한 냉각유로에서의 압력강하가 추진제 공급 시스템의 공급 압력의 한계값을 넘어서지 않도록 하며, 냉각후의 연료 또는 산화제의 열역학적 상태가 엔진 작동 조건에 적합하도록 제어하여야 한다.

  • PDF