• Title/Summary/Keyword: 냉각방식

Search Result 395, Processing Time 0.024 seconds

Combustion Performance of a Fullscale Liquid Rocket Thrust Chamber (실물형 액체로켓 연소기 지상 연소 성능 결과)

  • Seo Seong-Hyeon;Kim Jong-Gyu;Moon Il-Yoon;Han Yeoung-Min;Choi Hwan-Seok;Lee Soo-Yong;Cho Kwang-Rae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.235-239
    • /
    • 2005
  • A 30-tonf-class fullscale thrust chamber for the application to a LEO SLV has been combustion tested over the wide ranges of a mixture ratio and a chamber pressure. The thrust chamber designed for an open cycle engine with a turbopump was tested with a ablative combustion chamber instead of a regenerative chamber to first evaluate its performance and function. The test results revealed stable combustion characteristics. The hardware survived the harsh environment and showed very sound functional characteristics. The estimated combustion efficiency of the chamber turned out to be 95% and a specific impulse at sea level was estimated as 254sec, which are comparable to or above the predicted design values.

  • PDF

Combustion Experiments of a High Pressure Liquid Propellant Thrust Chamber (액체로켓 엔진용 고압 연소기의 연소시험)

  • Seo, Seong-Hyeon;Han, Yeoung-Min;Moon, Il-Yoon;Lee, Kwang-Jin;Kim, Jong-Kyu;Lim, Byung-Jik;Ahn, Kyu-Bok;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.40-46
    • /
    • 2006
  • A 30-tonf-class fullscale thrust chamber for the application to a Low-Earth-Orbit Space Launch Vehicle has been combustion tested over the wide ranges of a mixture ratio and a chamber pressure. The thrust chamber designed for a pump-fed open cycle engine was tested with an ablative chamber instead of a regenerative one for the initial evaluation of its performance and function. The test results revealed stable combustion characteristics. The hardware survived the harsh environment and showed very sound functional characteristics. The measured combustion efficiency turned out to be 95% and a specific impulse at sea level was estimated as 254sec, which are comparable to or above the predetermined design values.

A Study on Modeling Program Development of an Environmental Control System (환경조절장치(ECS)의 모델링 프로그램 개발에 관한 연구)

  • Yoo, Young-Joon;Lee, Hyung-Ju;Kho, Seong-Hee;Ki, Ja-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.5
    • /
    • pp.57-63
    • /
    • 2009
  • A modeling and simulation program for an environmental control system (ECS) of a pod installed under wings of an aircraft was developed in order to estimate the system‘s performance during a flight. First, through the system configuration analysis in the main operational condition of the aircraft system, an ECS configuration adopting an air cycle machine (ACM) was selected. Therefore the modeling program was developed to simulate the ECS with an ACM. Second, the sensitivity analyses on performance variation of main components were conducted to complete the conceptual design of the ECS. A design point for the system and its components was obtained through the analysis with the modeling and simulation program. The design point for the system and components was obtained through the analysis with the modeling and simulation program. Third, in order to study the feasibility of the ECS configuration, off-design performances of the ECS on various flight conditions, such as take off, maneuver, cruise and landing etc were estimated. Dynamic characteristics were analyzed by transient performance evaluations.

The implementation of liquefaction equipment monitoring system based on Android (안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현)

  • Park, Man-Kyu;Tack, Han-Ho;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.583-589
    • /
    • 2016
  • Volatile organic compounds(VOCs) are regarded as a harmful cause substance not only causing air pollutions but also causing global warming phenomenon. For this reason, VOCs are managed politically to reduce emissions by each country. In particular, the vapor from the gas station contains VOCs which is harmful to the human body such as carcinogens benzene and pollute the atmosphere, the Ministry of Environment defined every gas station must install vapor recovery equipment to recover volatile organic compounds. Recently, there are many accidents caused by existing vapor treatment methods, the liquefaction recovery technology is getting the spotlight to cool the vapor at the field. However, because the liquefaction recovery technology have risks of fire or explosion in accordance with temperature, the real time monitoring is critical factor. In this paper, we implement an Android-based monitoring application for liquified vapor recovery device which attached sensor module for temperature and power to monitoring real time information.

U-type Cross-Counter Indirect Evaporative Cooler made of Plastic/Paper (U형 직교 대향류 플라스틱/종이 재질 간접증발소자)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.732-739
    • /
    • 2016
  • In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.

Petrology of the Sanbangsan Lava Dome, Jeju Volcanic Field (제주도 산방산 용암돔(Lava Dome)의 구성암석에 대한 화산암석학적 연구)

  • Yun, Sung-Hyo
    • The Journal of the Petrological Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.307-317
    • /
    • 2019
  • Petrological studies were performed on the Sanbangsan lava dome, located in the southwest of Jeju Island Volcanic Field. According to the lava ejection method, it is 'an internal primitive form' that is gradually pushed up and expanded by continuous magma injection from the bottom to the top of the vent and it corresponds to the 'low lava dome'. The rocks are partly plotted in the field of benmoreite, but mostly plotted in the field of trachyte of the Cox et al.(1979) classification diagram, and also mainly plotted in the field of trachyte of Le Maitre et al.(2002) and Zr/TiO2-Nb/Y classification diagram. Therefore, the expression that described the rock of Sanbangsan lava dome as 'trachy-andesite' should be corrected to 'trachyte'. The volcanic rocks that consists in the Sanbangsan lava dome are trachyte containing normative quartz and shows differentiation trend in the range of 59.75-63.46 wt.% SiO2.

Numerical Simulation on the Spreading and Heat Transfer of Ex-Vessel Core Melt in a Channel (전산해석을 이용한 원자로 노심 용융물의 노외 거동 및 열전달 특성 분석)

  • Ye, In-Soo;Ryu, Chang-Kook;Ha, Kwang-Soon;Song, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.425-429
    • /
    • 2011
  • In the unlikely of nuclear reactor meltdown, the leaked core melt or corium must be contained in a device called core-catcher so that the corium can be cooled and stabilized. The ex-vessel behavior of corium involves complex physical and chemical mechanisms of flow propagation, heat transfer, and reactions with sacrificial substrates. In this study, the detailed characteristics of corium flow and heat transfer were investigated by using a commercial CFD code for VULCANO VE-U7 test reported in the literature. The volume-of-fluid (VOF) model was used to predict the interfacial surface formation of corium and the surrounding air, and the discrete ordinate model was adopted to calculate radiation between corium and the surroundings. It was found that cooling via radiation through the top surface of corium had a dominant effect on the temperature and viscosity profiles at the front of the corium flow.

NUMERICAL STUDY ON THE EFFECT OF THE SHAPE OF THE HEAT TRANSFER PLATE ON THE THERMAL PERFORMANCE OF THE RADIATOR (변압기용 방열기의 방열판 형상이 방열특성에 미치는 영향에 관한 수치적 연구)

  • Kim, Y.J.;Doo, J.H.;Ha, M.Y.;Son, S.W.;Kim, J.K.;Lee, S.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.65-76
    • /
    • 2015
  • In this study, the natural convection phenomenon of the air side and the forced convection phenomenon of the oil side were simulated in the radiator through a 3-D numerical analysis, and the total heat released by the oil side into the radiator heating plate and then to the air side was evaluated. Also, a quantitative analysis was carried out on the effect of each thermal resistance on the overall heat transfer coefficient through a 1-D thermal circuit analysis on the heat transfer mechanisms of the radiators considered in this study. In addition, for the diverse shapes of the heating plates considered in this study, the pressure drops of the oil side were quantitatively compared and evaluated. The temperatures at the air side and the oil side outlets of the radiators with 8 different fin shapes considered in this study had almost similar values showing a difference of +/-3% and, accordingly, the total heat transfer also showed similar heat dissipation performance in all the models. As a result of the 1-D thermal circuit analysis, in all the models considered in this study, while the thermal resistance of the air side accounted for 92% to 96% of the total, that of the oil side was 5 to 7%, and that of the heating plate showed a very small value of 0.02%.

Design of DC current waveform for expulsion reduction in resistance spot welding (저항 점 용접에서 날림발생 저감을 위한 DC 펄스전류 파형설계에 관한연구)

  • Hwang, In-Sung;Yeun, Hyun-Joon;Kim, Dong-Cheol;Kang, Mun-Jin
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.39-39
    • /
    • 2010
  • 최근 자동차 산업에서는 차체의 무게를 감소시켜 연비향상과 배기가스의 양을 줄이려는 목적으로 고강도 강재의 차체 적용이 증가하고 있다. 또한 다른 여러 산업에서도 두께 감소를 통한 경량화를 위해 고강도 강재가 사용되고 있다. 고강도 강재를 자동차 차체에 적용하면서 용접성에 대한 새로운 문제가 제기 되고 있으며 그 중 자동차 생산라인에서 차체의 조립공정의 대부분을 차지하는 저항 점 용접에 대한 연구가 중요한 이슈가 되고 있다. 이러한 고강도 강재의 저항 점 용접의 문제점으로는 잦은 날림발생을 들 수 있다. 이는 강도의 증가에 따른 비저항 증가와 필요 가압력의 증가로 인해 입열에 의한 가압부의 소성변형이 쉽게 발생하기 때문이다. 이를 방지하기 위해 현재 다단가압, 다단전류제어 등의 기법들이 시도되고 있다. 본 연구에서는 저항 점 용접의 펄스전류 파형설계를 통해 고강도강 용접의 날림발생을 저감하고자 하였다. 실험소재로는 Al-Si 도금의 1.5GPa 급 강재를 사용하였고 실험조건으로는 기존 로브곡선에서 날림이 발생하는 용접조건을 사용하였다. On/Off 방식의 펄스전류를 이용하여 On/Off 시간에 따른 용접성을 평가하여 이를 기존 용접성과 비교하였다. 또한 펄스전류 파형에 따른 입열과 냉각의 변화와 날림발생에 미치는 영향을 분석하였다.

  • PDF

Development and Analysis of the Autoclave Alternative Composite Material Molding Process Using a Pressure Device (가압장치를 이용한 오토클레이브 대체 복합재료 성형공정 개발 및 분석)

  • Kim, Jung-Soo;Kim, Byung-Ha;Joe, Chee-Ryong
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.254-259
    • /
    • 2014
  • In this study, a device and pressure press process that is able to substitute autoclave process is developed. This process complements disadvantages of autoclave process which are long process-time and high production cost. The developed device provides air pressure as well as the vacuum which are greatest feature of autoclave process. The device is sealed using hydraulic pressure to keep the air pressure inside the mold. The transfer of the heat is designed to be direct. The heating and pressure charging time are decreased by reducing the interior space. Tooling cost is reduced dramatically compared to autoclave process. Spring-back phenomenon is measured and compared. The temperatures of several parts of the mold during molding are measured. The fiber volume fraction of the parts molded by autoclave process and by the developed process are compared.