• Title/Summary/Keyword: 내화 성능

Search Result 577, Processing Time 0.022 seconds

An Analysis and Evaluation of Fire Resistance Performance for the Protected Steel Columns in Korea (국내 피복 철골기둥의 내화 성능 분석 및 평가)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2009
  • Main structural steel members need fire-resistance measures to ensure their fire-resistance performance for a prescribed time. This paper analyzes and evaluates the fire-resistance performance of approved Korean fire-protection products for steel columns. These products are classified into products for board protection and for spray protection, samples of which were selected for the analysis. The fire-resistance performance was analyzed on the basis of Korean and European standards. The Korean standards are considered additional to the Euro-code standards for performance design. The Korean standards generally take more precautions to ensure safety on the temperature side, but require the reflection of material properties, the steel temperature calculation methodology, the profile factor, and the strength verification in a fire.

The Study on the Fire Resistance Performance of the CFT (Concrete filled Tube) Column According to the Concrete Compressive Strength and Load Ratio (콘크리트 압축강도 및 하중비에 따른 CFT기둥의 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.44-51
    • /
    • 2010
  • This study, to develop the technology of the fire resistance design of CFT structure based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation of the CFT specimen as parameter is the concrete compressive strength and load ratio. In accordance with KS F 2257-1 and 7, 24 MPa and 40 MPa and the load ratio of 0.9, 0.6 and 0.2 were imposed on a square column and as a result of evaluating in accordance with the fire resistance criteria, in case of 24 MPa, the fire resistance performance was improved by 73 minutes when the load ratio was reduced by 0.3. And when it comes to 40 MPa, the fire resistance was 31 minutes and 180 minutes when a load ratio was 0.6 and 0.2, respectively. As a result of evaluating fire resistant performance depending on variation of internal concrete strength, it proved that the higher the strength the lower the fire resistance.

Fire Resistance Properties of High Strength Concrete Column using ECC Permanent Form (ECC 영구 거푸집을 활용한 고강도콘크리트 기둥부재의 내화특성)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.957-960
    • /
    • 2008
  • In this study, it was investigated fire resistance properties of high strength concrete column using Engineered Cementitious Composites(ECC) permanent form as a countermeasure for explosive spalling of concrete on fire. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete if it is developed manufacturing technique and scheme for application controlling heat penetration through interface of permanent form and high strength concrete, and setting up mix proportion and thickness of ECC.

  • PDF

Study on the Fire Resistance Performance of the TSC Beam (TSC 합성보의 내화성능에 관한 연구)

  • Kim, Sung Bae;Choi, Seng Kwan;Lee, Chang Nam;Kim, Sang Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.1
    • /
    • pp.113-122
    • /
    • 2006
  • The purpose of this paper is to evaluate the fire resistance of the TSC beam, a composite beam composed of a concrete beam enclosed by steel plates. Since a discrepancy was observed between the structural mechanisms of TSC and typical composite beams, the fire performances of the two beams are likewise believed to be partially dissimilar. In this experiment, small and medium-sized TSC beams were tested under given conditions in the laboratory, with/without one of the most widely used spray-on fire protections in Korea. Furthermore, based on the steel and concrete properties under elevated temperatures that were obtained from Eurocode, temperature development across the section was suggested, analyses. To determine the capacity of a modified plastic section, th e fire performance of the model was also examined.

An Evaluation for the Fire Resistance of Concrete-Filled Steel Square Tube Columns under Constant Axial Loads (일정 축력을 받는 콘크리트충전 각형 강관기둥의 내화성능 평가)

  • Park, Su Hee;Ryoo, Jae Yong;Chung, Kyung Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.703-714
    • /
    • 2007
  • The aim of this research is to evaluate the fire resistance of concrete-filled steel square tube columns (square CFT columns) under constant axial loads by numerical analysis. The authors examined the experimental results on the fire resistance of concrete-filled steel square tube columns without fire protection. As the materials of CFT columns, steel of SPSR 400 grade and concrete of 27.5MPa and 37.8MPa strengths were used. The significant parameters were determined, such as load ratio, cross-sectional dimensions, and concrete strength. Detailed analytical simulations of fire resistance and axial deformation showed good agreement with the experimental observations. Therefore, this numerical analysis exhibited a reasonable estimation of fire resistance of the square CFT column. Results of the numerical parametric studies showed that the fire resistance of the CFT columns increased with the decrease of the concrete strength and the increase of the cross-sectional dimensions about the constant axial load ratio ($N/N_c$).

Experimental Study on Fire Resistance Performance of Legal Slab under Standard Fire with Loading condition (표준화재 재하조건에서 법정슬래브의 내화성능에 관한 실험적 연구)

  • Cho, Bum-Yean;Yeo, In-Hwan;Kim, Heung-Youl;Min, Byung-Yeol;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.115-118
    • /
    • 2011
  • 본 연구에서는 현재 법정내화구조로 규정되어 있는 철근콘크리트(RC: Reinforced concrete)조 및 철골철망모르타르(SWM: Steel & Wire Mortar)조 슬래브에 대하여 재하조건에서 구조별 내화성능을 검토하고, 철골철망모르타르조 슬래브에 대해서는 피복두께별 내화성능을 검토하고자 표준화재조건에서 내화실험을 실시하였다. 실험결과 동일피복 두께일 경우 철근콘크리트조 슬래브가 내화성능이 우수한 것으로 나타났으며, 철골철망 모르타르조 슬래브의 경우 피복두께가 10mm 증가 시 7%의 내화성능이 향상되는 것으로 나타났다. 가열 이면온도는 슬래브의 두께가 늘어날수록 낮은 것으로 나타났다.

  • PDF

An Experimental Study on the Ensuring the Fire Resistance Performance of Non-Refractory Coating CFT (무내화피복 CFT 공법의 내화성능 확보를 위한 실험적 연구)

  • Lee, Ji-Hwan;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.3
    • /
    • pp.273-280
    • /
    • 2015
  • In this study, tests were carried out to find out a method to ensure the fire resistance performance of high-performance non-refractory coating CFT columns. For the high performance concrete fabrication with 100MPa, blast furnace slag(BS) and steel and nylon fibers were used. It was found that the partial replacement with BS improved the fire resistance performance of the concrete. Based on the results of lab tests, the large fire test was conducted. For this test, the CFTs with the size of ${\phi}500{\times}4,200mm$ and the reinforcement of SS 400 steel were prepared and they were subjected to a loading condition. It was found that as the level of load increased, the level of fire resistance decreased. For example, In with the loading condition of 2000kN the CFT could resist the fire for over 240 minutes, whereas, with the loading condition of 3,000kN and 4000kN applying to equivalent CFTs, the resisting time against fire were 184 minutes, and 120 minutes, respectively.

공동주택 경량벽체 내화성능기준 설정

  • An, Jae-Hong;Yeo, In-Hwan;Jo, Gyeong-Suk;Choe, Dong-Ho;Min, Byeong-Ryeol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.214-215
    • /
    • 2013
  • 공동주택을 기둥식 구조에서 공간을 구획하는 비내력 벽체로 사용되는 경략벽체에 요구되어지는 다양한 성능조건 중 내화성능 기준을 등급으로 구분하여 제시하고자 한다. 공동주택 경량벽체를 세대간 벽과 세대내 벽으로 구분하여 각각의 내화성능 요구수준에 맞는 성능등급을 설정하였으며, 이를 내화실험을 통하여 성능을 확인하였다.

  • PDF

The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass (내화유리를 적용한 강재 유리벽의 내화성능 평가)

  • Lee, Jae-Sung;Yim, Hyun-Chang;Yang, Seung-Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.72-81
    • /
    • 2018
  • Fireproof structures using concrete, built-up panels and dry walls are usually used in walls inside fire compartments. However, demand for glass walls is emerging due to increase in interest in visibility and external appearance. In this study on steel fire resistance walls using insulation glass, fire resistance tests and performance evaluations were conducted on 60 minute fire resistance walls and exterior walls which could be applied to interior fire compartments and 90 minute fire resistance walls which could be applied to curtain walls. According to the tests, the specimens satisfied the required fire resistance performance. The finite element analysis was conducted after the tests to evaluate the fire resistance performance of the glass walls. The analysis results showed that the preliminary evaluation of fire resistance performance would be feasible.

Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads (일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가)

  • Park, Su Hee;Song, Kyung Chul;Ryoo, Jae Yong;Chung, Kyung Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.655-663
    • /
    • 2008
  • In this research, the fire resistance of Concrete-Filled Circular Steel Tube Columns (CFT) was evaluated by numerical analysis. As the materials of CFT columns, the steel of SPSR 400 grade and the concrete of 27.5MPa, 37.8MPa strengths were used. Significant parameters,such as concrete strength, axial load, and cross-sectional dimensions were determined. To verify the accuracy of the numerical analysis,the analysis results were compared with the former experiment results. The effect of the fire resistance time, axial load ratio, cross-sectional dimensions and concrete strength was evaluated by comparison with the fire resistance of the square CFT columns. This research showed that the structural behavior and fire resistance from the findings of numerical parametric studies showed a similarity to that of the experimental results. Therefore, this numerical analysis is reasonable in estimating the fire resistance of the circular CFT column.